摘要 目的探讨工作场所空气中锑的标准测定方法中的样品处理条件。方法以硝酸作为消解液,在280℃消化温度下消解样本,应用火焰原子吸收光谱法对空气中锑进行测定。结果线性范围为0.00~40.00μg/mL,回归方程为y=0.0121x+0.0103,相关系数r=0.9992,方法检出限为0.14μg/mL;方法的定量下限为0.48μg/mL,最低定量浓度为0.06 mg/m3;批内精密度相对标准偏差为0.54%~1.47%,批间精密度相对标准偏差为0.84%~2.08%,加标回收率为98.48%~102.43%。结论该方法简便、快速、灵敏度高,测定结果准确可靠,有较高的实用价值,值得推广。 Objective To explore the sample treatment conditions in the standard method for determination of antimony in workplace air. Methods Using nitric acid as the only digestive liquid,the samples were digested at 280 ℃ and then the antimony was determined by flame atomic absorption spectrometry. Results The linear concentration range was 0.00-40.00 μg/mL,the regression equation was y=0.012 1 x+0.010 3,with the correlation coefficient(r) of 0.999 2,and the detection limit of the method was 0.14 μg/mL. The lower limit of quantification was 0.48 μg/mL and the lowest quantitative concentration was 0.06 mg/m^3. The relative standard deviations of intra-assay precision were 0.54%-1.47%,while the relative standard deviations of inter-assay precision were 0.84%-2.08%. The recovery rates were 98.48%-102.43%. Conclusion The method is simple,rapid,and sensitive,with accurate and reliable results. It has high practical value and is worth popularizing.
作者 熊伟 张宇峰 陈志亮 鲁青 郑丹 张裕曾 XIONG Wei;ZHANG Yu-feng;CHEN Zhi-liang;LU Qing;ZHENG Dan;ZHANG Yu-zeng(Ministry of Education Key Laboratory of Environment and Health,School of Public Health,Tongji Medical College,Huazhong University of Science and Technology,Wuhan Hubei,430030,China)
出处 《职业与健康》 CAS 2020年第16期2203-2206,共4页 Occupation and Health
关键词 火焰原子吸收法 空气中锑 硝酸 消化温度 Flame atomic absorption spectrometry Antimony in air Nitric acid Digestion temperature
  • 相关文献

参考文献15

二级参考文献102

共引文献47

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部