摘要
为了研究对比电化学发光免疫法与酶联免疫法检测标志物的结果,并加以分析,本文选取2018年7月—2019年12月鞍山市中心医院经门诊诊断疑似乙型肝炎患者150例,将其分为对照组和研究组进行检测,对照组采用酶联免疫法检测标志物,研究组采用电化学发光免疫法检测标志物,对比观察2组检出标志物的检出率以及灵敏度。结果显示,电化学发光免疫法检测乙型肝炎表面抗原(HBsAg)的检出率为61.33%,乙型肝炎E抗体(HBeAb)的检出率为24.00%。电化学发光免疫法检测HBsAg、HBeAb的检出率较酶联免疫法检测更高效,电化学发光免疫法具有更高的灵敏度,能提供较为准确的诊断依据。
In order to study and compare the results of the detection of markers by electrochemiluminescence immunoassay and enzyme-linked immunoassay,this paper selects 150 cases of suspected hepatitis B patients diagnosed by Anshan Central Hospital from July 2018 to December 2019.They are divided into a control group and a study group for detection.The control group uses enzyme-linked immunoassay to detect the markers,and the research group uses electrochemiluminescence immunoassay to detect the markers.The detection rate and sensitivity of the two groups are compared.The results show that the detection rate of HBsAg by electrochemiluminescence immunoassay is 61.33%,and the detection rate of HBeAb is 24.00%.The detection rate of electrochemiluminescence immunoassay to detect HBsAg and HBeAb is more efficient than enzyme-linked immunoassay.Electrochemiluminescence immunoassay has higher sensitivity and can provide a more accurate diagnosis basis.
作者
石剑雄
SHI Jianxiong(Anshan Central Hospital,Anshan,Liaoning,114001,China)
出处
《质量安全与检验检测》
2020年第5期123-125,共3页
QUALITY SAFETY INSPECTION AND TESTING
关键词
电化学发光免疫法
酶联免疫法
检测
标志物
Electrochemiluminescence Immunoassay
Enzyme-Linked Immunoassay
Detection
Marker