摘要 某300 MW机组的分隔屏过热器管与定位块连接处在长时间运行条件下发生泄漏。对泄漏管段进行了宏观形貌观察、成分分析、力学性能测试及金相组织观察。分析结果表明,各管段理化性能均符合标准要求,该过热器管泄漏的原因为由于焊接部位存在应力集中,在循环载荷的影响下产生疲劳裂纹,最终引起管道开裂。 Leakage occurred at the junction between the partition screen superheater tube and the positioning block of a 300 MW unit under long-term operating conditions. Macroscopic morphology observation, composition analysis, mechanical property test, and metallographic structure observation were performed on the leaking pipe sections. The test results show that the physical and chemical properties of each pipe section meet the standard requirements. The reason for the leakage of the super-heater pipe is that due to the stress concentration in the welding part, fatigue cracks occur under the influence of cyclic load,which eventually coused the pipes′ broken.
作者 曲同良 武芯羽 Qu Tongliang;Wu Xinyu(Huadian Qingdao Power Generation Co.,Ltd.,Qingdao,Shandong 266000,China;Suzhou Nuclear Power Research Institute Co.,Ltd.,Suzhou,Jiangsu 215004,China)
出处 《机电工程技术》 2021年第1期174-176,共3页 Mechanical & Electrical Engineering Technology
关键词 分隔屏过热器 泄漏 原因分析 partition screen super-heater leakage cause analysis
  • 相关文献

参考文献7

二级参考文献39

  • 1魏楠,金尧,孙训方.低周循环应力—应变关系和损伤[J].机械强度,2002,24(3):426-428. 被引量:4
  • 2颜建辉,张厚安,李益民,唐思文.不同致密度的MoSi_2材料在1200℃的循环氧化特性[J].矿冶工程,2006,26(6):81-83. 被引量:6
  • 3汽轮机、锅炉、发电机金属材料手册.上海:人民出版社,1973,32-33.
  • 4国家质量技术监督局.《锅炉定期检验规则》.1999,7.
  • 5GB5310-2008,高压锅炉用无缝钢管[s].
  • 6GB/T4340.1-2009,金属材料维氏硬度试验第1部分:试验方法[S].
  • 7美国金属学会.金属手册[M].北京:机械工业出版社,1986..
  • 8张彦华.焊接结构原理[M].北京:北京航空航天大学出版社,2011.
  • 9贾安东.焊接结构与产生[M].北京:机械工业出版社,2007.
  • 10李庆芳,胡胜海,朱世范.断裂力学及其工程运用[M].哈尔滨:哈尔滨工业大学出版社,1998.

共引文献46

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部