摘要 To further strengthen the protective effect of aerogel cement paste (ACP) coating on self-compacting concrete (SCC) in tunnel fire under the optimal mix proportion,the effect of curing temperature (from 5 to 80 ℃,based on site construction curing temperature and surrounding rock temperature) on fire insulation of ACP was investigated.The mechanical properties,thermal conductivity and porosity of ACP were tested.The microstructure of ACP was characterized by means of SEM,XRD and TG/DTG.The results reveal that 50 ℃ is the optimal curing temperature for ACP with good mechanical properties and fire insulation.Relatively high curing temperature can facilitate hydration and pozzolanic reactions,contributing to the generation of more stable substances (such as C-S-H gels,tobermorite and thenardite,etc).ACP under excessive low curing temperature brings inhomogeneous microstructure with coarse pores,leading to producing wider and longer microcracks when it is exposed to tunnel fire.The microcracks make the heat convection and thermal radiation more significant and thus accelerate the damage of ACP under fire.In case of the less than 7% difference of thermal conductivity,dense microstructure and stable substances are more conducive to strengthening fire insulation of ACP.In practical engineering applications,the thickness of protective layer of ACP can be further optimized when ACP is cured under about 50 ℃.
作者 WANG Xinjie XU Donghang ZHU Pinghua CHEN Chunhong QIAN Zhongqiu 王新杰;XU Donghang;朱平华;CHEN Chunhong;QIAN Zhongqiu(Department of Civil Engineering,Changzhou University,Changzhou 213164,China;Architectural Research Institute Group Co.,Ltd.,Changzhou 213164,China)
出处 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2021年第1期93-102,共10页 武汉理工大学学报(材料科学英文版)
基金 Funded by the National Natural Science Foundation of China(No.51678081) Natural Science Foundation of the Jiangsu Higher Education Institution of China(No.18KJB560001)。
  • 相关文献

参考文献2

二级参考文献12

  • 1Leitner A.The Fire Catastrophe in the Tauern Tunnel: Experience and Conclusions for the Austrian Guidelines[].Tunnelling and Underground Space Technology.2001
  • 2Hamoush S A,,Abdel-Fattah H,McGinley M W.Residual Fracture Toughness of Concrete Exposed to Elevated Temperature[].ACI Materials Journal.1998
  • 3Zhang B,Bicanic N,Pearce C J, et al.Assessment of Toughness of Concrete Subjected to Elevated Tempera- tures from Complete Load-displacement Curve: Part 2. Experimental Investigations[].ACI Material Journal.2000
  • 4Kertz K D.Limits of Spalling of Fire-exposed Concrete[].Fire Safety Journal.2003
  • 5RILEM Draft Recommendation TC50-FCM.Determination of fracture energy of mortar and concrete by means of three point bend tests on notched beams[].Materials and Structures.1985
  • 6Zhang B,Bicanic N,Pearce C Jet al.Relationship between brittleness and moisture loss of concrete exposed to high temperatures[].Cement and Concrete Composites.2002
  • 7Sanjayan G,Stocks L J.Spalling of High Strength Silica Fume Concrete in Fire[].ACI Materials Journal.1993
  • 8Kalifa,P.,Chené,G.,Gallé,C.High-temperature behaviour of hpc with polypropylene fibres: From spalling to microstructure[].Cement and Concrete Research.2001
  • 9Chan,S.Y.N.,Peng,G.F.,Anson,M.Fire behavior of high-performance concrete made with silica fume at various moisture contents[].ACI Materials Journal.1999
  • 10Pierre Kalifa,Francois-Dominique Menneteau,Daniel Quenard.Spalling and Pore Pressure in HPC at high temperatures[].Cem and Concr Res.2000

共引文献3

同被引文献4

引证文献1

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部