摘要
以海外华龙一号某核电发电机转子匝间短路装置在实际工程案例中的应用情况为例,分析了基于探测线圈法设计的检测装置的原理、数据采集和处理过程、参数配置等,并对原理和参数配置进行了深入的分析和总结,为后续四极核电发电机转子绕组匝间短路调试工作提供借鉴。
Taking the application of the rotor turn to turn short circuit device of a nuclear power generator of overseas HPR1000 as an example,the principle,data acquisition and processing process and parameter configuration of the detection device designed based on the detection coil method are analyzed.The principle and parameter configuration are analyzed and summarized in depth,which provides a reference for the subsequent inter turn short circuit commissioning of rotor winding of four pole nuclear power generator.
作者
曹望刚
宋成洋
洪琪旭
王晓琳
王伟
CAO Wanggang;SONG Chengyang;HONG Qixu;WANG Xiaolin;WANG Wei(China National Nuclear Power Operation Management Co.,Ltd.,Jiaxing 314300,China)
出处
《电工技术》
2021年第22期30-32,共3页
Electric Engineering
关键词
华龙一号
核电
发电机
匝间短路
HPR1000
nuclear power
generator
turn-to-turn short circuit