期刊文献+

高压单芯电缆不等长交叉互联接地环流分析 被引量:3

Analysis of Grounding Circulating Current for High-voltage Single-core Cables in Unequal-length Cross-bonding Connection
在线阅读 下载PDF
导出
摘要 研究单芯电缆金属护套在交叉互联接地情况下的等值电路,建立金属护套交叉互联数学模型,编写Matlab程序,计算交叉互联单元内电缆布置方式和段长不一致时的金属护套环流,并对段长与金属护套环流大小的关系进行了分析。为减少金属护套环流,高压单芯电缆在满足电缆载流量的前提下,应尽可能采用正三角形布置方式且段长尽量相等。 The equivalent circuit of single-core cable metal sheath in cross-bonding grounding is researched,the mathematical model of cross-bonding metal sheath is established,and a Matlab program is coded.The circulating current in the sheaths is calcu⁃lated for the cable connection with different arrangements and lengths in the cross-bonding grounding unit,and the relationship between the length and circulating current in the sheaths is analyzed.In order to reduce the circulating current in the sheaths,the high-voltage single-core cable should take equilateral triangle arrangement with the same cable length under the right ampacity of power cable.
作者 王爱华 张勇 刘云杰 田连博 芦灯 WANG Aihua;ZHANG Yong;LIU Yunjie;TIAN Lianbo;LU Deng(Shandong Electric Power Engineering Consulting Institute Co.,Ltd.,Jinan 250013,China)
出处 《山东电力高等专科学校学报》 2022年第1期1-4,共4页 Journal of Shandong Electric Power College
关键词 电力电缆 护套环流 交叉互联 布置方式 power cable circulating current in sheath cross-bonding arrangement mode