期刊文献+

阴极对电化学消毒效果及无机氯副产物生成的影响研究

Study on effect of cathode on electrochemical disinfection and generation of inorganic chlorine by-products
在线阅读 下载PDF
导出
摘要 采用循环流反应器,以DSA(Ti/IrO_(2)-RuO_(2))电极为阳极,考察了3种不同材质阴极(CuZn合金、Ti、Zn)对电化学消毒效果及无机消毒副产物生成的影响,同时探究了电流密度、初始Cl-浓度与初始pH对该过程的影响。结果表明,在相同的实验条件下,阴极材质的改变对电化学消毒效果无明显影响,但采用CuZn合金阴极较其余2种阴极生成的氯酸盐更少。电化学析氯消毒对大肠杆菌的灭活效果随着电流密度与初始Cl-浓度的升高而升高,随pH升高而降低。 The impacts of three different cathode materials(CuZn alloy,Ti and Zn)on the electrochemical disinfection performance and the generation of inorganic disinfection by-products are investigated in a recirculating flow reactor with DSA(Ti/IrO_(2)-RuO_(2))as the anode.Meanwhile,the influences of current density,initial Cl-concentration and initial pH value on the circulating flow reaction are explored.It is found that the impact of different cathode materials on disinfection performance is insignificant under the same experimental conditions.However,the production of chlorate by applying CuZn alloy as the cathode is less than that by using the other two materials as cathode.In addition,the inactivation effect of E-coli by electrochemical chlorine-evolution disinfection increases with the increases of current density and initial Cl-concentration,and decreases with the increase of pH.
作者 庞锐 张峰 崔建国 PANG Rui;ZHANG Feng;CUI Jian-guo(College of Environmental Science and Engineering,Taiyuan University of Technology,Jinzhong 030600,China)
出处 《现代化工》 CAS CSCD 北大核心 2023年第2期149-154,共6页 Modern Chemical Industry
基金 山西省自然科学基金面上项目(20210302124110)。
关键词 电化学消毒 阴极材质 活性氯 大肠杆菌 消毒副产物 electrochemical disinfection cathode material active chlorine E-coli disinfection by-products
  • 相关文献

参考文献4

二级参考文献29

  • 1吴清平,孙永,蔡芷荷,郭伟鹏.快速测试片在食品微生物检测中的应用[J].中国卫生检验杂志,2006,16(5):635-637. 被引量:39
  • 2王岽,魏新,王洪英,郦和生.DPD分光光度法测定循环水中余氯的改进[J].石化技术,2006,13(3):30-32. 被引量:15
  • 3[1]Li X Y,Diao H F,Fan F X J,et al,Electrochemical wastewater disinfection:Identification of its principal germicidal actions.Journal of Environmental engineering(ASCE),2004,(130):1217~1221
  • 4[2]Fang Q,Shang C,Chen G H,et al,MS2 Inactivation by chloride-assisted electrochemical disinfection.Journal of Environmental Engineering(ASCE),2006,(132):13~22
  • 5[3]Venczel L V,Arrowood M,Hurd M,et al,Inactivation of cryptosporidium parvum oocysts and clostridium perfringens spores by a mixed-oxidant disinfectant and by free chlorine.Applied and Environmental Microbiology,1997,(63):1598~1601
  • 6[4]Bergmann M E H,Kopral A S.Studies on electrochemical disinfectant production using anodes containg RuO2.Journal of Applied electrochemistry,2005,(35):132~1329
  • 7[5]Troster I,Fryda M,Herrmann D,et al.Electrochemical advanced oxidation process for water treatment using diachem electrode.Diamond and Related Material,2002,(11):640~645
  • 8[6]Furuta T,Tanaka H,Nishiki Y,et al.Legionella inactivation with diamond electrodes.Diamond and Related materials,2004(13):2016~2019
  • 9[7]Panizza M,Cerisola G.Application of diamond electrodes to electrochemical processs.Electrochemical Acta,2005,(51):191~199
  • 10[8]Kraft A,Stadelmann M,Wunsche M,et al.Electrochemical destruction of organic substance in deionized water using diamond anodes and a solid polymer electrolyte.Electrochemistry Communications,2006,(8):155~158