摘要
目的探究产后尿潴留实施低频电子脉冲仪治疗的效果。方法随机选取2022年10月—2023年10月巨野县人民医院收治的50例产后尿潴留患者为研究对象,用抽签法分为传统组和治疗组,每组均25例。传统组使用传统诱导排尿治疗,治疗组增加低频电子脉冲治疗仪治疗。监测两组患者的尿动力学指标,观察恢复情况,统计有效率。结果治疗前,两组患者的膀胱逼尿肌收缩力和膀胱顺应性对比,差异无统计学意义(t=0.417、0.126,P均>0.05)。治疗后,治疗组患者的膀胱逼尿肌收缩力和膀胱顺应性优于传统组,差异有统计学意义(t=7.376、17.530,P均<0.05)。治疗组患者的残余尿量低于传统组,差异有统计学意义(P<0.05)。治疗组患者的30 min自行排尿率高于传统组,差异有统计学意义(χ^(2)=5.882,P=0.015)。治疗组患者的总有效率(100.00%)高于传统组(80.00%),差异有统计学意义(χ^(2)=5.556,P=0.018)。结论使用低频电子脉冲治疗仪治疗患者的有效率高,能恢复尿动力学状态,优化排尿效果,加快子宫复旧,控制出血量,利于改善产后尿潴留患者的生活质量。
Objective To explore the effect of low frequency electronic pulse meter on postpartum urinary retention.Methods A total of 50 cases of postpartum urinary retention patients admitted to Juye County People's Hospital from October 2022 to October 2023 were selected as research objects,and were randomly di⁃vided into the traditional group and the treatment group by lot drawing,with 25 cases in each group.The tradi⁃tional group used traditional induction urination therapy,while the treatment group added low-frequency elec⁃tronic pulse therapy equipment.The urodynamic indexes were monitored,the recovery situation was observed,and the effective rates were calculated of both groups of patients.Results Before treatment,there was no statisti⁃cally significant difference in detrusor contractionality and bladder compliance between the two groups of pa⁃tients(t=0.417,0.126,both P>0.05).After treatment,the detrusor contractile force and bladder compliance of the treatment group were better than those of the traditional group,and the differences were significant(t=7.376,17.530,both P<0.05).The residual urine volume of the treatment group was lower than that of the tradi⁃tional group,and the difference was statistically significant(P<0.05).The rate of spontaneous urination at 30 min of patients in the treatment group was higher than that in the traditional group,and the difference was sta⁃tistically significant(χ^(2)=5.882,P=0.015).The total effective rate of patients in the treatment group(100.00%)was higher than that in the traditional group(80.00%),and the difference was statistically significant(χ^(2)=5.556,P=0.018).Conclusion The low frequency electronic pulse therapy instrument has high efficiency,can re⁃store the urodynamic state,optimize the effect of urination,accelerate uterine relapse,control the amount of blood loss,and improve the quality of life of patients with postpartum urinary retention.
作者
张燕
高香荣
许迎春
ZHANG Yan;GAO Xiangrong;XU Yingchun(Department of Obstetrics,Juye County People's Hospital,Heze,Shandong Province,274900 China)
出处
《世界复合医学》
2024年第1期173-176,共4页
World Journal of Complex Medicine
关键词
产后尿潴留
生活质量
有效率
低频电子脉冲治疗仪
Postpartum urinary retention
Quality of life
Efficient
Low frequency electronic pulse therapy apparatus