期刊文献+

透水混凝土基层的抗淤堵试验方法设计研究

Design and Research on the Anti silting Test Method for Permeable Concrete Base
在线阅读 下载PDF
导出
摘要 透水混凝土基层是“海绵城市”建设中道路铺装的重要组成层位,但在使用过程中难免会产生淤堵现象,造成透水功能失效,部分或全部丧失其使用功能。本文在结合有关研究的基础上,制备泥浆模拟透水混凝土基层的淤堵介质,设计了一种抗淤堵性能试验测试过程,通过多次试验循环了解和测试其渗透性能的衰减情况,并通过扫描电镜方式观测其内部孔隙受淤堵后的变化情况,为透水混凝土的进一步应用及使用过程中的养护维修提供相关参考。 Permeable concrete base is an important component layer of road pavement in the construction of“sponge city”,but it is inevitable to produce silting phenomenon in the process of use,resulting in the failure of permeable function and partial or total loss of its use function.On the basis of relevant research,this paper selects saturated slurry to simulate the blocking medium of permeable concrete base,designs a test process of anti-blocking performance,understands and tests the attenuation of its permeability through multiple test cycles,and observes the change of its internal voids after being blocked by scanning electron microscope,providing relevant reference for the further application of permeable concrete and maintenance during use.
作者 李博楠 LI Bonan(CCRB Science and Technology Co.,Ltd.,Shijiazhuang Hebei 050011,China)
出处 《交通节能与环保》 2024年第5期198-200,共3页 Transport Energy Conservation & Environmental Protection
基金 河北省建设科技研究指导性计划项目(2022—2042)。
关键词 海绵城市 透水混凝土 基层 抗淤堵 扫描电镜 sponge city permeable concrete the basic level anti-clogging scanning electron microscope
  • 相关文献

参考文献4

二级参考文献29

共引文献12

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部