基于模块选择的级联H桥型静止无功发生器直流侧电容在线状态监测策略

Online Condition Monitoring Strategy of Capacitors in Cascaded-H-Bridge Static Var Generator Based on Module Selection
在线阅读 下载PDF
导出
摘要 直流侧电容是级联H桥(CHB)型静止无功发生器(SVG)系统的核心元件,在长期运行过程中将承受复杂的应力冲击,如何在线针对其健康状态进行实时监测对于系统的可靠运行十分关键。对此,该文提出一种基于模块选择的CHB-SVG电容在线监测策略。通过已采集的控制量计算出可反映容值大小的健康指标K,通过排序逐次筛选电容容值最低的子模块,并利用特殊开关模态将容值最小的模块从系统中旁路,构建独立放电通路,通过放电曲线实现对容值的准确测量。该方法不依赖外加传感器,不影响系统的正常运行,无需复杂算法,容值监测精度高,且具有推广价值。仿真和实验证明了该文所提策略的有效性。 The DC-link capacitor is the core component of the cascaded H-bridge(CHB)static var generator(SVG)system.It withstands complex electrical stress during long-term operation,and an online condition monitoring of its health status is critical to the reliable operation of the system.This paper proposes an online condition monitoring strategy for CHB-SVG capacitors based on module selection.According to the collected control signals,the parameter reflecting the capacitance value is calculated to sort the capacitance value of each module.Then,a special switching mode is used to bypass the module with the smallest capacitance from the system,establishing an independent discharging path.An accurate measurement of the capacitance is achieved through the discharging curve.The proposed method does not rely on extra sensors or affect the normal operation of the system,and no complicated algorithms are required.Firstly,a health indicator of each capacitor is calculated using the existing control signals to select the most fragile module among all CHB modules.Based on the power balancing equation,the health-related indicator K is given,disproportional to the capacitance C.This process can be conducted during normal operation without heavy computational burden.By repeating this process,the degradation trend of each capacitor is monitored in real-time.Once the K is larger than a certain value,the specific module is considered at risk.However,the result can only roughly report potential capacitor failure risk,and the accurate capacitance value cannot be acquired.After locating the risky module,a special switching mode is applied to create an independent internal discharging curve.In this process,the grid-side current is isolated with the capacitor,and an RC discharging path is established.The capacitor voltage is decreasing,which can be measured by the existing voltage sensor.The capacitance value is calculated accurately using the discharging curve.However,extra bypassing and inserting actions are produced,and the power loss during this process is substantial.With the proposed two steps,the risky module is located at the first step,and its capacitance is acquired by the discharging curve at the second step.The overall cost and monitoring accuracy are both guaranteed.The simulation is carried out in Matlab/Simulink,and a three-module CHB prototype is built and operates under SVG mode.The results show that the overall accuracy is above 95%,verifying the effectiveness of the proposed method.The method also works well in similar CHB structures,such as motor drives and PV systems,and is promising to be integrated into existing projects.
作者 王涵宇 邱荣禄 吴家伟 杨柳 张兴 Wang Hanyu;Qiu Ronglu;Wu Jiawei;Yang Liu;Zhang Xing(National and Local Joint Engineering Laboratory for Renewable Energy Access to Grid Technology Hefei University of Technology,Hefei 230009 China)
出处 《电工技术学报》 北大核心 2025年第4期1169-1179,共11页 Transactions of China Electrotechnical Society
基金 国家自然科学基金青年基金(52107187) 中央高校基本科研业务费专项资金资助项目。
关键词 级联H桥 电容 状态监测 静止无功发生器 Cascade H-bridge capacitor condition monitoring static var generator
  • 相关文献

参考文献12

二级参考文献132

共引文献265

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部