期刊文献+

溶胶-凝胶法固定胆固醇氧化酶偶联普鲁士蓝化学修饰电极的研究 被引量:14

Cholesterol Biosensors Based on Cholesterol Oxidase Immobilized in a Silica Sol-gel Matrix on a Prussian Blue Modified Electrode
在线阅读 下载PDF
导出
摘要 用溶胶-凝胶法将胆固醇氧化酶固定在普鲁士蓝修饰的玻碳电极表面,制成了一种新型胆固醇传感器,实现了低电位下对胆固醇的间接测定,胆固醇的测定范围伏安法为5×10^(-7)~8×10^(-5)mol/L,安培法为5×10^(-6)~5×10^(-4)mol/L。伏安法检出限为1.2×10^(-7)mol/L,是目前所见灵敏度最高的胆固醇传感器之一,该传感器对胆固醇的测定可避免常规电化学传感器测定中由于样品中大量存在的易氧化物质所带来的干扰,该传感器的寿命长,使用次数在300次以上。 A cholesterol biosensor prepared by immobilization of cholesterol oxidase in a silica sol-gel matrix on the surface of Prussian Blue-modified glass carbon electrode was reported. The properties of the sensor were investigated. It is based on the detection of hydrogen peroxide produced by ChOx at 0. 0-- 0. 1 V. The measurements conditions were optimized. Cholesterol can be determined in the concentration range of 5 × 10-7-8 × 10-5 mol/L by voltammetry or 5 ×10-6-5 × 10-4 mol/L by amperometry. The method gives a high sensitivity owing to the electrocatalytic layer of Prussian Blue to the electro-reduction of enzymatic production of hydrogen peroxide. In addition, the effect of easily oxidizable substances presented in samples such as ascorbic acid and uric acid can be minimized.
出处 《高等学校化学学报》 SCIE EI CAS CSCD 北大核心 2003年第5期798-802,共5页 Chemical Journal of Chinese Universities
基金 国家自然科学基金(批准号:29975024) 浙江省自然科学基金 浙江省分析测试基金
关键词 溶胶-凝胶法 固定化 胆固醇氧化酶 普鲁士蓝 化学修饰电极 生物传感器 胆固醇 测定 Biosensor Cholesterol oxidase Prussian Blue Sol-gel Electrode
  • 相关文献

参考文献21

  • 1JIN Wen-Rui(金文睿) WANG Nai-Xing(汪乃兴) PENG Tu-Zhi(彭图治.Bioe1ectrochemica1 Ana1ysis(生物电分析化学)[M].Jinan:Shandong University Press,1994.101.
  • 2DONG Sha-Jun(董绍俊) CHE Guang-Li(车广礼) XIE Yuan-Wu(谢远武.Chemica11y Modified E1ectrodes(化学修饰电极)[M].Beijing:Science Press,1995..
  • 3Maclachlan J. , Wotherspoon A. T. L. , Ansell R. O. et al.. J. Steroid Biochem. Molecular Biology[J], 2000, 72: 169-195.
  • 4Wang H. , Mu S.. Sens. Actuators B.. Chemical[J], 1999, 56: 22-30.
  • 5Besombes J. L. , Cosnier S. , Labbé P.. Talanta[J], 1997, 44: 2209-2215.
  • 6Vidal J. C. , Garcia E. , Castillo J. R.. Sens. Actuators B: Chemical[J], 1999, 57: 210-226.
  • 7Vidal J. C. , Gareia-Ruiz E. , Castillo J. R.. J. Pharm. and Biomedical Anal. [J], 2000, 24: 51-63.
  • 8Kaszuba M. , Jones M. N.. Biochim. Biophys. Acta: Biomembranes[J], 1999, 1419:221-228.
  • 9Nakaminami T. , Ito S. , Kuwabata S. et al.. Anal. Chem. [J], 1999, 71:1068-1076.
  • 10Bongiovanni C. , Ferri T. , Poscia A. et al., Bioelectrochem. [J], 2001, 54: 17-22.

同被引文献189

引证文献14

二级引证文献55

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部