期刊文献+

含甲醛毒性废水电-Fenton试剂氧化技术研究 被引量:39

Oxidation Treatment of Formaldehyde-containing Wastewater by Electro-Fenton Method
在线阅读 下载PDF
导出
摘要 研究了以活性炭粒子为填充电极的填充床式电 Fenton反应装置处理自配甲醛毒性有机废水时各影响因子的作用机制 ,通过正交实验和单因素实验确定了各影响因子的最佳操作条件为 :反应时间 90min ,反应体系 pH值<3 5 ,涂膜炭填充比例 4 0 % ,电压 2 5V ,Fe2 +浓度 30 0mg/L ,反应温度 30℃~ 4 0℃ .结合氧化产物的紫外光谱分析 ,提出甲醛电 Fenton氧化反应机理 .利用电 Fenton试剂氧化法对实际洗胶废水进行连续处理 ,甲醛及CODCr的去除率分别在 90 %及 30 %左右 ,运行费用较Fenton试剂法降低 4 2 3% . The mechanisms of affecting factors in treating formaldehyde-containing organic wastewater by electro-Fenton reactor which had granular carbon as the filled electrode were investigated. The optimal operating conditions determined by orthogonal experiments and individual factor experiments were as following: 90min, 25V, 30℃~40℃, insulating carbon content 40%, Fe 2+ concentration 300mg/L at pH<3.5. Formaldehyde degradation mechanisms were proposed after analyzing the oxidation products with UV absorbance spectrum. Experiment of treating the actual wastewater using this method were also performed.The removal rates of formaldehyde and COD Cr were about 90%, 30%, respectively. In addition, the operating cost was 42.3% less than that of treatment by Fenton method.
出处 《环境科学》 EI CAS CSCD 北大核心 2003年第6期106-111,共6页 Environmental Science
基金 国家自然科学基金资助项目 (编号 :2 98770 0 9 2 0 2 770 10 ) 广东省及广州市环保科技项目
关键词 含甲醛废水 电-Fenton反应 三维填充电极 催化氧化 毒性 formaldehyde-containing wastewater electro-fenton reaction three-dimensional filled electrode catalytic oxidation