期刊文献+

Preliminary experience with drug-coated balloon angioplasty in primary percutaneous coronary intervention 被引量:15

Preliminary experience with drug-coated balloon angioplasty in primary percutaneous coronary intervention
在线阅读 下载PDF
导出
摘要 We evaluated the clinical feasibility of using drugcoated balloon(DCB) angioplasty in patients undergoingprimary percutaneous coronary intervention(PPCI). Between January 2010 to September 2014,89 STelevation myocardial infarction patients(83% male,mean age 59 ± 14 years) with a total of 89 coronary lesions were treated with DCB during PPCI. Clinical outcomes are reported at 30 d follow-up. Left anterior descending artery was the most common target vessel for PCI(37%). Twenty-eight percent of the patients had underlying diabetes mellitus. Mean left ventricular ejection fraction was 44% ± 11%. DCB-only PCI was the predominant approach(96%) with the remaining 4% of patients receiving bail-out stenting. Thrombolysis in Myocardial Infarction(TIMI) 3 flow was successfully restored in 98% of patients. An average of 1.2 ± 0.5 DCB were used per patient,with mean DCB diameter of 2.6 ± 0.5 mm and average length of 23.2 ± 10.2 mm. At 30-d follow-up,there were 4 deaths(4.5%). No patients experienced abrupt closure of the infarctrelated artery and there was no reported target-lesion failure. Our preliminary experience showed that DCB angioplasty in PPCI was feasible and associated with a high rate of TIMI 3 flow and low 30-d ischaemic event. We evaluated the clinical feasibility of using drugcoated balloon(DCB) angioplasty in patients undergoingprimary percutaneous coronary intervention(PPCI). Between January 2010 to September 2014,89 STelevation myocardial infarction patients(83% male,mean age 59 ± 14 years) with a total of 89 coronary lesions were treated with DCB during PPCI. Clinical outcomes are reported at 30 d follow-up. Left anterior descending artery was the most common target vessel for PCI(37%). Twenty-eight percent of the patients had underlying diabetes mellitus. Mean left ventricular ejection fraction was 44% ± 11%. DCB-only PCI was the predominant approach(96%) with the remaining 4% of patients receiving bail-out stenting. Thrombolysis in Myocardial Infarction(TIMI) 3 flow was successfully restored in 98% of patients. An average of 1.2 ± 0.5 DCB were used per patient,with mean DCB diameter of 2.6 ± 0.5 mm and average length of 23.2 ± 10.2 mm. At 30-d follow-up,there were 4 deaths(4.5%). No patients experienced abrupt closure of the infarctrelated artery and there was no reported target-lesion failure. Our preliminary experience showed that DCB angioplasty in PPCI was feasible and associated with a high rate of TIMI 3 flow and low 30-d ischaemic event.
出处 《World Journal of Cardiology》 CAS 2015年第6期311-314,共4页 世界心脏病学杂志(英文版)(电子版)
关键词 Acute MYOCARDIAL INFARCTION DRUG COATED BALLOON Efficacy Primary ANGIOPLASTY Safety Acute myocardial infarction Drug coated balloon Efficacy Primary angioplasty Safety
  • 相关文献

参考文献10

  • 1SeQuent Please World Wide Registry[J]. Journal of the American College of Cardiology . 2012 (18)
  • 2Bruno Scheller,Ulrich Speck,Claudia Abramjuk,Ulrich Bernhardt,Michael B?hm,Georg Nickenig.Paclitaxel Balloon Coating, a Novel Method for Prevention and Therapy of Restenosis[J]. Circulation . 2004 (7)
  • 3Ellen C Keeley,Judith A Boura,Cindy L Grines.Primary angioplasty versus intravenous thrombolytic therapy for acute myocardial infarction: a quantitative review of 23 randomised trials[J]. The Lancet . 2003 (9351)
  • 4David A Cox,Gregg W Stone,Cindy L Grines,Thomas Stuckey,David J Cohen,James E Tcheng,Eulogio Garcia,Giulio Guagliumi,Robert S Iwaoka,Martin Fahy,Mark Turco,Alexandra J Lansky,John J Griffin,Roxana Mehran.Outcomes of optimal or “stent-like”balloon angioplasty in acutemyocardial infarction: the CADILLAC trial[J]. Journal of the American College of Cardiology . 2003 (6)
  • 5Huber M S,Mooney J F,Madison J,Mooney M R.Use of a morphologic classification to predict clinical outcome after dissection from coronary angioplasty. The American Journal of Cardiology . 1991
  • 6Grines C L,Cox D A,Stone G W,et al.Coronary angioplasty with or without stent implantation for acute myocardial infarction. The New England Journal of Medicine . 1999
  • 7Stone Gregg W,Grines Cindy L,Cox David A,Garcia Eulogio,Tcheng James E,Griffin John J,Guagliumi Giulio,Stuckey Thomas,Turco Mark,Carroll John D,Rutherford Barry D,Lansky Alexandra J.Comparison of angioplasty with stenting, with or without abciximab, in acute myocardial infarction. The New England Quarterly . 2002
  • 8Stone Gregg W,Lansky Alexandra J,Pocock Stuart J,Gersh Bernard J,Dangas George,Wong S Chiu,Witzenbichler Bernhard,Guagliumi Giulio,Peruga Jan Z,Brodie Bruce R,Dudek Dariusz,M?ckel Martin,Ochala Andrzej,Kellock Alison,Parise Helen,Mehran Rox.Paclitaxel-eluting stents versus bare-metal stents in acute myocardial infarction. The New England Quarterly . 2009
  • 9Franz X. Kleber,Detlef G. Mathey,Harald Rittger.How to use the drug-eluting balloon: recommendations by the German consensus group. EUROINTERVENTION . 2011
  • 10Ho HH,Ooi YW,Loh KK,Tan J,Aung TH,Jafary FH,Ong PJL.Clinical Efficacy and Safety of SeQ uent Please Paclitaxel-Eluting Balloon in a Real-World Single-Center Registry of South-East Asian Patients. Int J Cardiol Heart Vessels . 2013

共引文献1

同被引文献21

引证文献15

二级引证文献71

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部