摘要 介绍了330kV罐式断路器中六氟化硫(SF6)气体湿度测量的意义、原理和系统。对11台330kV罐式断路器进行了湿度测量 ,发现环境温度对SF6 气体湿度有显著影响。环境温度升高时 ,SF6气体湿度升高。通过理论分析 ,认为吸附作用是导致SF6 气体湿度随环境温度变化而变化的原因。 The benefit,principle and facilities of moisture measurement of SF 6 gas in330kV tank circuit-breakers are introduced in the paper.According to the experimental results,a conclusion that environmental temperature does influence the moisture of SF 6 gas can be drawn.When the temperature rises,the moisture rises correspondingly.The absorption existing on the surface between SF 6 gas and solid materials of circuit-breakers is the reason that causes the phenomenon above-mentioned.
出处 《绝缘材料》 CAS 北大核心 2004年第2期35-37,共3页 Insulating Materials
关键词 断路器 六氟化硫 湿度 circuit-breaker sulphur hexafluoride moisture
  • 相关文献

参考文献4

  • 1C.Pradayrol,et al. Influence of O2 and H2O on the spark decom position of SF6 and SF6+ 50% CF4 mixtures[C]. Conference record of the 1996 IEEE international symposium on electrical insulation, Quebec, Canada, 1996. 823~ 827.
  • 2M.Piemontesi,et al.Analysis of decomposition products of sulfur hexafluoride in negative DC corona with special emphasis on con tent of H2O and O2[C]. Conference record of the 1994 IEEE international symposium on electrical insulation, Pittsburgh, USA, 19
  • 3IEEE Std 1125- 1993, IEEE guide for moisture measurement and control in SF6 gas- insulated equipment [S].
  • 4GB8905-88.六氟化硫电气设备中气体管理和检测导则 [S].[S].,..