Objective To investigate the image quality, radiation dose and diagnostic value of the low-tube-voltage high-pitch dual-source computed tomography(DSCT) with sinogram affirmed iterative reconstruction(SAFIRE) for non-...Objective To investigate the image quality, radiation dose and diagnostic value of the low-tube-voltage high-pitch dual-source computed tomography(DSCT) with sinogram affirmed iterative reconstruction(SAFIRE) for non-enhanced abdominal and pelvic scans. Methods This institutional review board-approved prospective study included 64 patients who gave written informed consent for additional abdominal and pelvic scan with DSCT in the period from November to December 2012. The patients underwent standard non-enhanced CT scans(protocol 1) [tube voltage of 120 k Vp/pitch of 0.9/filtered back-projection(FBP) reconstruction] followed by high-pitch non-enhanced CT scans(protocol 2)(100 k Vp/3.0/SAFIRE). The total scan time, mean CT number, signal-to-noise ratio(SNR), image quality, lesion detectability and radiation dose were compared between the two protocols. Results The total scan time of protocol 2 was significantly shorter than that of protocol 1(1.4±0.1 seconds vs. 7.6±0.6 seconds, P<0.001). There was no significant difference between protocol 1 and protocol 2 in mean CT number of all organs(liver, 55.4±6.3 HU vs. 56.1±6.8 HU, P=0.214; pancreas, 43.6±5.9 HU vs. 43.7±5.8 HU, P=0.785; spleen, 47.9±3.9 HU vs. 49.4±4.3 HU, P=0.128; kidney, 32.2±2.3 HU vs. 33.1±2.3 HU, P=0.367; abdominal aorta, 44.8±5.6 HU vs. 45.0±5.5 HU, P=0.499; psoas muscle, 50.7±4.1 HU vs. 50.3±4.5 HU, P=0.279). SNR on images of protocol 2 was higher than that of protocol 1(liver, 5.0±1.2 vs. 4.5±1.1, P<0.001; pancreas, 4.0±1.0 vs. 3.6±0.8, P<0.001; spleen, 4.7±1.0 vs. 4.1±0.9, P<0.001; kidney, 3.1±0.6 vs. 2.8±0.6, P<0.001; abdominal aorta, 4.1±1.0 vs. 3.8±1.0, P<0.001; psoas muscle, 4.5±1.1 vs. 4.3±1.2, P=0.012). The overall image noise of protocol 2 was lower than that of protocol1(9.8±3.1 HU vs. 11.1±3.0 HU, P<0.001). Image quality of protocol 2 was good but lower than that of protocol 1(4.1±0.7 vs. 4.6±0.5, P<0.001). Protocol 2 perceived 229 of 234 lesions(97.9%) that were detected in protocol 1 in the abdomen and pelvis. Radiation dose of protocol 2 was lower than that of protocol 1(4.4±0.4 m Sv vs. 7.3±2.4 m Sv, P<0.001) and the mean dose reduction was 41.4%. Conclusion The high-pitch DSCT with SAFIRE can shorten scan time and reduce radiation dose while preserving image quality in non-enhanced abdominal and pelvic scans.展开更多
Truncus arteriosus is an uncommon congenital cardiac abnormality which is characterized by a single arterial trunk origin from the heart that supplies both the systemic,pulmonary and coronary circulation.We present a ...Truncus arteriosus is an uncommon congenital cardiac abnormality which is characterized by a single arterial trunk origin from the heart that supplies both the systemic,pulmonary and coronary circulation.We present a preterm newborn female patient with type 2 truncusarteriosus,left superior vena cava and aberrant subclavian artery diagnosed with low dose dual-source cardiac computed tomography(CT).We discuss that low dose dual-source cardiac CT has more advantages than other imaging methods and it is an important modality for assessment of patients with conotruncal anomalies such as truncusarteriosus.展开更多
Background:Pulmonary atresia(PA)is a group of heterogeneous complex congenital heart disease.Only one study modality might not get a correct diagnosis.This study aims to investigate the diagnostic power of dualsource ...Background:Pulmonary atresia(PA)is a group of heterogeneous complex congenital heart disease.Only one study modality might not get a correct diagnosis.This study aims to investigate the diagnostic power of dualsource computed tomography(DSCT)for all intracardiac and extracardiac deformities in patients with PA compared with transthoracic echocardiography(TTE).Materials and Methods:This retrospective study enrolled 79 patients and divided them into three groups according to their main diagnosis.All associated malformations and clinical information,including treatments,were recorded and compared among the three groups.The diagnostic power of DSCT and TTE on all associated malformations were compared.The surgical index(McGoon ratio,pulmonary arterials index(PAI),and total neopulmonary arterial index)and radiation dose were calculated on the basis of DSCT.Results:Of the patients,32,30,and 17 were divided into the groups of PA with ventricular septal defect(VSD),PA with VSD and major aortopulmonary collateral arteries,and PA with other major malformations,respectively.Consequently,182,162,and 13 intracardiac,extracardiac,and other major malformations were diagnosed,respectively.Moreover,DSCT showed a better diagnostic performance in extracardiac deformities(154 vs.117,p<0.001),whereas TTE could diagnose intracardiac deformities better(159 vs.139,p=0.001).The McGoon ratio,PAI,and treatment methods were significantly different among the three groups(p=0.014,p=0.008,and p=0.018,respectively).Conclusion:More than one imaging modality should be used to make a correct diagnosis when clinically suspecting PA.DSCT is superior to TTE in diagnosing extracardiac deformities and could be used to roughly calculate surgical indices to optimize treatment strategy.展开更多
Objective To prospectively investigate the diagnostic accuracy for coronary artery stenosis of prospectively electrocardiogram-triggered spiral acquisition mode (high pitch mode) dual-source computed tomography corona...Objective To prospectively investigate the diagnostic accuracy for coronary artery stenosis of prospectively electrocardiogram-triggered spiral acquisition mode (high pitch mode) dual-source computed tomography coronary angiography (CTCA) in patients with relatively higher heart rates (HR) compared with catheter coronary angiography (CCA). Methods Forty-seven consecutive patients with relatively higher HR (>65 and <100 bpm) (20 male, 27 female; age 55±10 years) who both underwent dual-source CTCA and CCA were prospectively included in this study. All patients were performed CTCA using high pitch mode setting at 20%-30% of the R-R interval for the image acquisition. All coronary segments were evaluated by two blinded and independent observers with regard to image quality on a three-point scale (1: excellent to 3: non-diagnostic) and for the presence of significant coronary stenoses (defined as diameter narrowing exceeding 50%). Considered CCA as the standard of reference, the sensitivity, specificity, positive predictive value and negative predictive value were calculated. Radiation dose values were calculated using the dose-length product. Results Image quality was rated as being score 1 in 92.4% of segments, score 2 in 6.1% of segmentsand score 3 in 1.5% of segments. The average image quality score per segment was 1.064±0.306. The HR variability of patients with image score 1, 2 and 3 were 2.29±1.06 bpm, 5.17±1.37 bpm, 8.88±1.53 bpm, respectively. The average HR variability of patients with different image scores were significantly different (F=170.402, P=0.001). The sensitivity, specificity, positive and negative predictive values were 92.6%, 97.0%, 87.6%, 98.3%, respectively, per segment and 90.0%, 95.2%, 85.3%, 96.9%, respectively, per vessel and 100%, 63.6%, 90.0%, 100%, respectively, per patient. The effective radiation dose was on average 0.86±0.16 mSv. Conclusion In patients with HR more than 65 bpm and below 100 bpm without cardiac arrhythmia, the prospectively electrocardiogram-gated high-pitch spiral acquisition mode with image acquired timing set at 20%-30% of the R-R interval provides a high diagnostic accuracy for the assessment of coronary stenoses combined with a 1.5% of non-diagnostic coronary segments and a radiation dose below 1 mSv.展开更多
Objective To investigate the feasibility of acquiring the similar homogeneous enhancement using bolus-tracking techniques with shortened respiratory time in prospectively electrocardiogram-gated high-pitch spiral acqu...Objective To investigate the feasibility of acquiring the similar homogeneous enhancement using bolus-tracking techniques with shortened respiratory time in prospectively electrocardiogram-gated high-pitch spiral acquisition mode (Flash mode) coronary computed tomography angiography (CCTA) compared with test bolus technique. Methods One hundred and eighty-four consecutive patients with mean heart rate ≤65 beats per minute undergoing CCTA were prospectively included in this study. The patients were randomly divided into two groups. Patients in the group A (n=92) instructed to shorten respiratory time received CCTA using bolus-tracking technique with high-pitch spiral acquisition mode (Flash mode), while those in the group B (n=92) underwent CCTA with test bolus technique. The attenuation in the ascending aorta, image noise, contrast-to-noise ratio and radiation doses of the two groups were assessed. Results There were no significant differences in the mean attenuation values in the ascending aorta (483.18±59.07 HU vs. 498.7±83.51 HU, P=0.183), image noise (21.4±4.5 HU vs. 20.9±4.3 HU, P=0.414), contrast-to-noise ratio (12.1±4.2 vs. 13.8±5.1, P=0.31) between the groups A and B. There were no significant differences in the radiation dose of dynamic monitoring scans (0.056±0.026 mSv vs. 0.062±0.018 mSv, P=0.068) and radiation dose of angiography (0.94±0.07 mSv vs. 0.96±0.15 mSv,P=0.926) between the two groups, while 15 mL less contrast material volume was administered in the group A than the group B. Conclusion Bolus-tracking technique with shortened time of respiratory in Flash mode of dual-source CT yields the similar homogeneous enhancement with less contrast material in comparison to the test bolus technique.展开更多
Dual-energy X-ray absorptiometry provides two modes of head computed tomography (CT) angiography scanning: neuro-digital subtraction angiography and dual-energy CT angiography (DE-CTA). Previous studies have comp...Dual-energy X-ray absorptiometry provides two modes of head computed tomography (CT) angiography scanning: neuro-digital subtraction angiography and dual-energy CT angiography (DE-CTA). Previous studies have compared image quality, radiation exposure, and bone removal between neuro-digital subtraction angiography and DE-CTA. However, the number of cases was relatively small. The present study examined 300 suspected cases of cerebrovascular disease and observed the methods and duration of post-processing, examination time, and data volume. Results demonstrated similar image quality between the two methods, but lower radiation doses and shorter examination time in DE-CTA. DE-CTA allowed for faster and more stable scanning performance and post-processing methods, facilitating accurate and direct diagnosis of cerebrovascular disease.展开更多
Objectives: Evaluation of radiation efficiency of dual source high-pitch (DSHP) chest CT in comparison to single source technique with special regards to individual patient anatomy. Methods: 150 consecutive patients w...Objectives: Evaluation of radiation efficiency of dual source high-pitch (DSHP) chest CT in comparison to single source technique with special regards to individual patient anatomy. Methods: 150 consecutive patients who underwent chest CT with automated tube current modulation were evaluated retrospectively and divided into three study groups, each with an equal quantity of 50 patients (DSHP vs. single source 128 slices vs. single source 16 slices). By using a dedicated workstation, volumetric analyses of each of the scanned anatomic area were performed and correlated to the individual dose length product (DLP). The calculated result was defined as dose efficiency. Results: DLP was 203 mGycm (DSHP), vs. 269 mGycm (single source) vs. 273 mGycm (16 slice CT). The total patient volume was lowest in the dual source group with 18956.3 cm3 (vs. 22481.2 cm3 vs. 22133.8 cm3). With regards to the DLP, the calculated dose efficiency of dual source CT was better than the 128 slice CT (p = 0.045) and the 16 slice CT (p < 0.01). Conclusions: DSHP CT has considerably better dose efficiency compared to 16 slice CT. Compared to 128 slice single source technique, the high-pitch mode does not cause any dose penalty when performing chest CT.展开更多
Background:Accurate assessment of intra-as well as extra-cardiac malformations and radiation dosage concerns are especially crucial to infants and children with interrupted aortic arch (IAA).The purpose of this stu...Background:Accurate assessment of intra-as well as extra-cardiac malformations and radiation dosage concerns are especially crucial to infants and children with interrupted aortic arch (IAA).The purpose of this study is to investigate the value of prospective electrocardiogram (ECG)-triggered dual-source computed tomography (DSCT) angiography with low-dosage techniques in the diagnosis of IAA.Methods:Thirteen patients with suspected IAA underwent prospective ECG-triggered DSCT scan and transthoracic echocardiography (TTE).Surgery was performed on all the patients.A five-point scale was used to assess image quality.The diagnostic accuracy ofDSCT angiography and TTE was compared with the surgical findings as the reference standard.A nonparametric Chi-square test was used for comparative analysis.P<0.05 was considered as a significant difference.The mean effective radiation dose (ED) was calculated.Results:Diagnostic DSCT images were obtained for all the patients.Thirteen IAA cases with 60 separate cardiovascular anomalies were confirmed by surgical findings.The diagnostic accuracy of TTE and DSCT for total cardiovascular malformations was 93.7% and 97.9% (P>0.05),and that for extra-cardiac vascular malformations was 92.3% and 99.0% (P < 0.05),respectively.The mean score of image quality was 3.77 ± 0.83.The mean ED was 0.30 ± 0.04 mSv (range from 0.23 mSv to 0.39 mSv).Conclusions:In infants and children with IAA,prospective ECG-triggered DSCT with low radiation exposure and high diagnostic efficiency has higher accuracy compared to TTE in detection of extra-cardiac vascular anomalies.展开更多
Background Doppler color echocardiography is a common method for detecting coronary artery lesions in patients with Kawasaki disease(KD).However,the diagnostic accuracy for the whole coronary artery lesions is limit...Background Doppler color echocardiography is a common method for detecting coronary artery lesions in patients with Kawasaki disease(KD).However,the diagnostic accuracy for the whole coronary artery lesions is limited.The purpose of this study was to compare the diagnostic value of dual-source computed tomography (DSCT) and Doppler color echocardiography for the assessment of coronary artery lesions caused by KD.Methods Sixteen patients,12 with typical KD and 4 with atypical KD,underwent DSCT and Doppler color echocardiography.The position and internal diameter of each coronary artery lesion was measured.Correlation analysis was used to compare the diagnostic value of the two imaging modalities.Results ln the typical KD group, seven patients did not have any coronary artery Iesion as confirmed by both DSCT scans and Doppler color echocardiography;in four patients proximal coronary artery injuries were identified by both modalities;in one patient an aneurysm in the middle and distal segments of the coronary artery was detected by DSCT but was negative in Doppler color echocardiography.In the atypical KD group,three cases showed the same results with both modalities,while one case with coronary artery stenosis in the middle segment was identified by DSCT but not detected by Doppler color echocardiography.There was a good correlation between the two imaging modalities(Kappa value,0.768(≥0.75)).Conclusion DSCT coronary artery angiography is an accurate,non-invasive,and valuable technique for detecting and following up coronary artery lesions in patients with KD.展开更多
Purpose: To explore the significance of dual-source computed tomography (DECT) virtual monoenergetic reconstructions technology in improving image quality for portal vein system of pancreatic cancer patients. Material...Purpose: To explore the significance of dual-source computed tomography (DECT) virtual monoenergetic reconstructions technology in improving image quality for portal vein system of pancreatic cancer patients. Materials and methods: 47 patients with clinically suspected pancreatic cancer (all confirmed by pathology) were collected. Routine plain scan was performed with Siemens Force dual-source dual-energy CT followed by 3 scans respectively carried out in arterial phase, portal phase and delayed phase. Traditional virtual monoenergetic reconstructions (Mono_E) and new generation of virtual monoenergetic reconstructions (Mono+) were respectively performed on portal vein images to obtain virtual single energy images including Mono_ E70 keV, Mono_E 55 keV and Mono+ 70 keV and Mono+ 55 keV. The signal-to-noise ratio (SNR) and noise of portal vein, normal pancreatic tissues and pancreatic lesions of 100 kV, Mono_E and Mono+ images were compared. In addition, the contrast noise ratio of portal vein and lesions as well as pancreatic tissues and lesions (CNR PV, CNRtumor) were also compared. At the same time, two imaging physicians with rich clinical experiences read the films and scored the images of each group by using the 5-point scoring method. Results: Mono+ 55 keV images including SNRpv, SNRpanc, SNRtumor, Noise, CNRpv, CNRtumor were statistically different from 100 KV images and Mono_E images (P < 0.05). As for the subjective score, Mono+ 55 keV image score also had the highest score, which had statistical significance (P < 0.05). The results showed that Mono+ 55 keV images had the best quality. Conclusion: The new generation of virtual Mono+ post-treatment can reduce image noise. Low energy Mono+ images can improve the contrast between pancreatic cancer lesions and portal of pancreatic cancer patients.展开更多
Purpose: To explore the significance of dual-source computed tomography (DECT) virtual monoenergetic reconstructions technology in improving the imaging quality of esophageal cancer patients. Materials and methods: 68...Purpose: To explore the significance of dual-source computed tomography (DECT) virtual monoenergetic reconstructions technology in improving the imaging quality of esophageal cancer patients. Materials and methods: 68 patients with clinically suspected esophageal cancer (all confirmed by pathology) were collected. Routine plain scan was performed with SIEMENS Force dual-energy CT and then dual-phase scans were performed. The venous phase images were respectively subjected to traditional virtual monoenergetic reconstructions (Mono_E) and new generation virtual monoenergetic reconstructions (Mono+). Mono_E 55 keV and Mono+ 55 keV virtual single-energy images were obtained respectively. The signal-to-noise ratio (SNR) of normal esophageal tissue and esophageal cancer lesions, noise and contrast noise ratio (CNR tumor) of normal esophageal tissue and esophageal cancer lesions were compared among 100 kV images, Mono_E images and Mono+ images. At the same time, two imaging physicians read the films and scored the images of each group by using a 5-point scoring method. Results: Mono+ 55 keV images, SNR, SNRtumor, noise and CNRtumor were statistically different from those of 100 kV images and Mono_E images (P < 0.05). And Mono+ 55 keV images also had the highest subjective score, with statistical significance (P 55 keV images had the best quality. Conclusion: The new generation of virtual monoenergetic reconstructions post-processing (Mono+) could reduce image noise and improve the contrast between esophageal cancer lesions and normal esophageal tissues, which was of great significance to improve the imaging quality of esophageal cancer patients and improve the early detection rate of esophageal cancer.展开更多
Objective: The aim of this study is to investigate if dual-source computed tomography (DSCT) could guide the percutaneous coronary intervention (PCI) of chronic total occlusion (CTO). Methods: We enrolled pati...Objective: The aim of this study is to investigate if dual-source computed tomography (DSCT) could guide the percutaneous coronary intervention (PCI) of chronic total occlusion (CTO). Methods: We enrolled patients who were confirmed to have at least one native coronary artery CTO by DSCT before they underwent selective PCI in the period from December 2007 to October 2008. A CTO was defined as an obstruction of a native coronary artery with no luminal continuity. The CT-guided PCI procedure involved placing CT and fluoroscopic images side-by-side on the screen. DSCT images were analyzed for location, segment, plaque characteristics, calcification, and proximal lumen diameter of the CTO before PCI. The guidewire was advanced and manipulated under CT guidance. The PCI was carried out and the results were compared. Results: Seventy-four CTOs were assessed. PCI was successful in 57 cases of CTOs (77.0%). According to the results, CTOs were divided into two groups: successfuI-PCI and failed-PCI. All coronary artery paths of CTOs were clearly recognized by DSCT. In the successfuI-PCI group, soft plaques were detected much more often than those in the failed-PCI group, but fibrous and calcified plaques were seen more often in the failed-PCI group. Calcification severity in CTO segments showed a significant difference between the groups (P=0.014). Calcified plaques were detected in 20 (35.1%) lesions in the successfuI-PCI group. More than 70% of the failures were calcified plaques, of which there were two arc-calcified and one circular-calcified lesions. Occlusions were longer in the failed-PCI group than those in the successfuI-PCI group [(38.8±25.0) vs. (18.0±15.3) mm, respec- tively, P〈0.01]. Fewer guidewires were used in the successfuI-PCI group compared with the failed-PCI group (1.7±1.0 vs. 2.5±0.9, respectively, P〈0.01). The logistic regression analysis indicated that predictors of recanalization of CTOs included occlusion length (P=-0.0035, risk ratio (RR)=0.93) and calcification severity (P=0.05, RR=0.27). Multi-linear trends analysis showed that the factors affecting procedural time were CTO location (P=-0.0141) and occlusion length (P=0.0035). Conclusions: DSCT could delineate the path of CTOs and characterize plaques. The outcomes of PCI were related to thrombolysis in myocardial infarction (TIMI) flow grade, CTO characteristics, severity of calcified plaques and the length of occlusive segments. Occlusion length and calcification severity were independent predictors of CTOs. Occlusion length and CTO segments could also help to estimate the duration of interventional procedures.展开更多
文摘Objective To investigate the image quality, radiation dose and diagnostic value of the low-tube-voltage high-pitch dual-source computed tomography(DSCT) with sinogram affirmed iterative reconstruction(SAFIRE) for non-enhanced abdominal and pelvic scans. Methods This institutional review board-approved prospective study included 64 patients who gave written informed consent for additional abdominal and pelvic scan with DSCT in the period from November to December 2012. The patients underwent standard non-enhanced CT scans(protocol 1) [tube voltage of 120 k Vp/pitch of 0.9/filtered back-projection(FBP) reconstruction] followed by high-pitch non-enhanced CT scans(protocol 2)(100 k Vp/3.0/SAFIRE). The total scan time, mean CT number, signal-to-noise ratio(SNR), image quality, lesion detectability and radiation dose were compared between the two protocols. Results The total scan time of protocol 2 was significantly shorter than that of protocol 1(1.4±0.1 seconds vs. 7.6±0.6 seconds, P<0.001). There was no significant difference between protocol 1 and protocol 2 in mean CT number of all organs(liver, 55.4±6.3 HU vs. 56.1±6.8 HU, P=0.214; pancreas, 43.6±5.9 HU vs. 43.7±5.8 HU, P=0.785; spleen, 47.9±3.9 HU vs. 49.4±4.3 HU, P=0.128; kidney, 32.2±2.3 HU vs. 33.1±2.3 HU, P=0.367; abdominal aorta, 44.8±5.6 HU vs. 45.0±5.5 HU, P=0.499; psoas muscle, 50.7±4.1 HU vs. 50.3±4.5 HU, P=0.279). SNR on images of protocol 2 was higher than that of protocol 1(liver, 5.0±1.2 vs. 4.5±1.1, P<0.001; pancreas, 4.0±1.0 vs. 3.6±0.8, P<0.001; spleen, 4.7±1.0 vs. 4.1±0.9, P<0.001; kidney, 3.1±0.6 vs. 2.8±0.6, P<0.001; abdominal aorta, 4.1±1.0 vs. 3.8±1.0, P<0.001; psoas muscle, 4.5±1.1 vs. 4.3±1.2, P=0.012). The overall image noise of protocol 2 was lower than that of protocol1(9.8±3.1 HU vs. 11.1±3.0 HU, P<0.001). Image quality of protocol 2 was good but lower than that of protocol 1(4.1±0.7 vs. 4.6±0.5, P<0.001). Protocol 2 perceived 229 of 234 lesions(97.9%) that were detected in protocol 1 in the abdomen and pelvis. Radiation dose of protocol 2 was lower than that of protocol 1(4.4±0.4 m Sv vs. 7.3±2.4 m Sv, P<0.001) and the mean dose reduction was 41.4%. Conclusion The high-pitch DSCT with SAFIRE can shorten scan time and reduce radiation dose while preserving image quality in non-enhanced abdominal and pelvic scans.
文摘Truncus arteriosus is an uncommon congenital cardiac abnormality which is characterized by a single arterial trunk origin from the heart that supplies both the systemic,pulmonary and coronary circulation.We present a preterm newborn female patient with type 2 truncusarteriosus,left superior vena cava and aberrant subclavian artery diagnosed with low dose dual-source cardiac computed tomography(CT).We discuss that low dose dual-source cardiac CT has more advantages than other imaging methods and it is an important modality for assessment of patients with conotruncal anomalies such as truncusarteriosus.
基金This study was approved by the Institutional Ethics Committee of West China Hospital,Sichuan University (Chengdu, Sichuan, ChinaNo. 14-163)+1 种基金This study has received funding by Sichuan Science and Technology Program(2020YJ0229)1⋅3⋅5 Project for Disciplines of Excellence,West China Hospital,Sichuan University(ZYGD18013)。
文摘Background:Pulmonary atresia(PA)is a group of heterogeneous complex congenital heart disease.Only one study modality might not get a correct diagnosis.This study aims to investigate the diagnostic power of dualsource computed tomography(DSCT)for all intracardiac and extracardiac deformities in patients with PA compared with transthoracic echocardiography(TTE).Materials and Methods:This retrospective study enrolled 79 patients and divided them into three groups according to their main diagnosis.All associated malformations and clinical information,including treatments,were recorded and compared among the three groups.The diagnostic power of DSCT and TTE on all associated malformations were compared.The surgical index(McGoon ratio,pulmonary arterials index(PAI),and total neopulmonary arterial index)and radiation dose were calculated on the basis of DSCT.Results:Of the patients,32,30,and 17 were divided into the groups of PA with ventricular septal defect(VSD),PA with VSD and major aortopulmonary collateral arteries,and PA with other major malformations,respectively.Consequently,182,162,and 13 intracardiac,extracardiac,and other major malformations were diagnosed,respectively.Moreover,DSCT showed a better diagnostic performance in extracardiac deformities(154 vs.117,p<0.001),whereas TTE could diagnose intracardiac deformities better(159 vs.139,p=0.001).The McGoon ratio,PAI,and treatment methods were significantly different among the three groups(p=0.014,p=0.008,and p=0.018,respectively).Conclusion:More than one imaging modality should be used to make a correct diagnosis when clinically suspecting PA.DSCT is superior to TTE in diagnosing extracardiac deformities and could be used to roughly calculate surgical indices to optimize treatment strategy.
基金Supported by the Ministry of Science and Technology of Inner Mongolia, China (20110504)
文摘Objective To prospectively investigate the diagnostic accuracy for coronary artery stenosis of prospectively electrocardiogram-triggered spiral acquisition mode (high pitch mode) dual-source computed tomography coronary angiography (CTCA) in patients with relatively higher heart rates (HR) compared with catheter coronary angiography (CCA). Methods Forty-seven consecutive patients with relatively higher HR (>65 and <100 bpm) (20 male, 27 female; age 55±10 years) who both underwent dual-source CTCA and CCA were prospectively included in this study. All patients were performed CTCA using high pitch mode setting at 20%-30% of the R-R interval for the image acquisition. All coronary segments were evaluated by two blinded and independent observers with regard to image quality on a three-point scale (1: excellent to 3: non-diagnostic) and for the presence of significant coronary stenoses (defined as diameter narrowing exceeding 50%). Considered CCA as the standard of reference, the sensitivity, specificity, positive predictive value and negative predictive value were calculated. Radiation dose values were calculated using the dose-length product. Results Image quality was rated as being score 1 in 92.4% of segments, score 2 in 6.1% of segmentsand score 3 in 1.5% of segments. The average image quality score per segment was 1.064±0.306. The HR variability of patients with image score 1, 2 and 3 were 2.29±1.06 bpm, 5.17±1.37 bpm, 8.88±1.53 bpm, respectively. The average HR variability of patients with different image scores were significantly different (F=170.402, P=0.001). The sensitivity, specificity, positive and negative predictive values were 92.6%, 97.0%, 87.6%, 98.3%, respectively, per segment and 90.0%, 95.2%, 85.3%, 96.9%, respectively, per vessel and 100%, 63.6%, 90.0%, 100%, respectively, per patient. The effective radiation dose was on average 0.86±0.16 mSv. Conclusion In patients with HR more than 65 bpm and below 100 bpm without cardiac arrhythmia, the prospectively electrocardiogram-gated high-pitch spiral acquisition mode with image acquired timing set at 20%-30% of the R-R interval provides a high diagnostic accuracy for the assessment of coronary stenoses combined with a 1.5% of non-diagnostic coronary segments and a radiation dose below 1 mSv.
基金Supported by the Ministry of Science and Technology of Inner Mongolia, China (20110504)
文摘Objective To investigate the feasibility of acquiring the similar homogeneous enhancement using bolus-tracking techniques with shortened respiratory time in prospectively electrocardiogram-gated high-pitch spiral acquisition mode (Flash mode) coronary computed tomography angiography (CCTA) compared with test bolus technique. Methods One hundred and eighty-four consecutive patients with mean heart rate ≤65 beats per minute undergoing CCTA were prospectively included in this study. The patients were randomly divided into two groups. Patients in the group A (n=92) instructed to shorten respiratory time received CCTA using bolus-tracking technique with high-pitch spiral acquisition mode (Flash mode), while those in the group B (n=92) underwent CCTA with test bolus technique. The attenuation in the ascending aorta, image noise, contrast-to-noise ratio and radiation doses of the two groups were assessed. Results There were no significant differences in the mean attenuation values in the ascending aorta (483.18±59.07 HU vs. 498.7±83.51 HU, P=0.183), image noise (21.4±4.5 HU vs. 20.9±4.3 HU, P=0.414), contrast-to-noise ratio (12.1±4.2 vs. 13.8±5.1, P=0.31) between the groups A and B. There were no significant differences in the radiation dose of dynamic monitoring scans (0.056±0.026 mSv vs. 0.062±0.018 mSv, P=0.068) and radiation dose of angiography (0.94±0.07 mSv vs. 0.96±0.15 mSv,P=0.926) between the two groups, while 15 mL less contrast material volume was administered in the group A than the group B. Conclusion Bolus-tracking technique with shortened time of respiratory in Flash mode of dual-source CT yields the similar homogeneous enhancement with less contrast material in comparison to the test bolus technique.
文摘Dual-energy X-ray absorptiometry provides two modes of head computed tomography (CT) angiography scanning: neuro-digital subtraction angiography and dual-energy CT angiography (DE-CTA). Previous studies have compared image quality, radiation exposure, and bone removal between neuro-digital subtraction angiography and DE-CTA. However, the number of cases was relatively small. The present study examined 300 suspected cases of cerebrovascular disease and observed the methods and duration of post-processing, examination time, and data volume. Results demonstrated similar image quality between the two methods, but lower radiation doses and shorter examination time in DE-CTA. DE-CTA allowed for faster and more stable scanning performance and post-processing methods, facilitating accurate and direct diagnosis of cerebrovascular disease.
文摘Objectives: Evaluation of radiation efficiency of dual source high-pitch (DSHP) chest CT in comparison to single source technique with special regards to individual patient anatomy. Methods: 150 consecutive patients who underwent chest CT with automated tube current modulation were evaluated retrospectively and divided into three study groups, each with an equal quantity of 50 patients (DSHP vs. single source 128 slices vs. single source 16 slices). By using a dedicated workstation, volumetric analyses of each of the scanned anatomic area were performed and correlated to the individual dose length product (DLP). The calculated result was defined as dose efficiency. Results: DLP was 203 mGycm (DSHP), vs. 269 mGycm (single source) vs. 273 mGycm (16 slice CT). The total patient volume was lowest in the dual source group with 18956.3 cm3 (vs. 22481.2 cm3 vs. 22133.8 cm3). With regards to the DLP, the calculated dose efficiency of dual source CT was better than the 128 slice CT (p = 0.045) and the 16 slice CT (p < 0.01). Conclusions: DSHP CT has considerably better dose efficiency compared to 16 slice CT. Compared to 128 slice single source technique, the high-pitch mode does not cause any dose penalty when performing chest CT.
文摘Background:Accurate assessment of intra-as well as extra-cardiac malformations and radiation dosage concerns are especially crucial to infants and children with interrupted aortic arch (IAA).The purpose of this study is to investigate the value of prospective electrocardiogram (ECG)-triggered dual-source computed tomography (DSCT) angiography with low-dosage techniques in the diagnosis of IAA.Methods:Thirteen patients with suspected IAA underwent prospective ECG-triggered DSCT scan and transthoracic echocardiography (TTE).Surgery was performed on all the patients.A five-point scale was used to assess image quality.The diagnostic accuracy ofDSCT angiography and TTE was compared with the surgical findings as the reference standard.A nonparametric Chi-square test was used for comparative analysis.P<0.05 was considered as a significant difference.The mean effective radiation dose (ED) was calculated.Results:Diagnostic DSCT images were obtained for all the patients.Thirteen IAA cases with 60 separate cardiovascular anomalies were confirmed by surgical findings.The diagnostic accuracy of TTE and DSCT for total cardiovascular malformations was 93.7% and 97.9% (P>0.05),and that for extra-cardiac vascular malformations was 92.3% and 99.0% (P < 0.05),respectively.The mean score of image quality was 3.77 ± 0.83.The mean ED was 0.30 ± 0.04 mSv (range from 0.23 mSv to 0.39 mSv).Conclusions:In infants and children with IAA,prospective ECG-triggered DSCT with low radiation exposure and high diagnostic efficiency has higher accuracy compared to TTE in detection of extra-cardiac vascular anomalies.
文摘Background Doppler color echocardiography is a common method for detecting coronary artery lesions in patients with Kawasaki disease(KD).However,the diagnostic accuracy for the whole coronary artery lesions is limited.The purpose of this study was to compare the diagnostic value of dual-source computed tomography (DSCT) and Doppler color echocardiography for the assessment of coronary artery lesions caused by KD.Methods Sixteen patients,12 with typical KD and 4 with atypical KD,underwent DSCT and Doppler color echocardiography.The position and internal diameter of each coronary artery lesion was measured.Correlation analysis was used to compare the diagnostic value of the two imaging modalities.Results ln the typical KD group, seven patients did not have any coronary artery Iesion as confirmed by both DSCT scans and Doppler color echocardiography;in four patients proximal coronary artery injuries were identified by both modalities;in one patient an aneurysm in the middle and distal segments of the coronary artery was detected by DSCT but was negative in Doppler color echocardiography.In the atypical KD group,three cases showed the same results with both modalities,while one case with coronary artery stenosis in the middle segment was identified by DSCT but not detected by Doppler color echocardiography.There was a good correlation between the two imaging modalities(Kappa value,0.768(≥0.75)).Conclusion DSCT coronary artery angiography is an accurate,non-invasive,and valuable technique for detecting and following up coronary artery lesions in patients with KD.
文摘Purpose: To explore the significance of dual-source computed tomography (DECT) virtual monoenergetic reconstructions technology in improving image quality for portal vein system of pancreatic cancer patients. Materials and methods: 47 patients with clinically suspected pancreatic cancer (all confirmed by pathology) were collected. Routine plain scan was performed with Siemens Force dual-source dual-energy CT followed by 3 scans respectively carried out in arterial phase, portal phase and delayed phase. Traditional virtual monoenergetic reconstructions (Mono_E) and new generation of virtual monoenergetic reconstructions (Mono+) were respectively performed on portal vein images to obtain virtual single energy images including Mono_ E70 keV, Mono_E 55 keV and Mono+ 70 keV and Mono+ 55 keV. The signal-to-noise ratio (SNR) and noise of portal vein, normal pancreatic tissues and pancreatic lesions of 100 kV, Mono_E and Mono+ images were compared. In addition, the contrast noise ratio of portal vein and lesions as well as pancreatic tissues and lesions (CNR PV, CNRtumor) were also compared. At the same time, two imaging physicians with rich clinical experiences read the films and scored the images of each group by using the 5-point scoring method. Results: Mono+ 55 keV images including SNRpv, SNRpanc, SNRtumor, Noise, CNRpv, CNRtumor were statistically different from 100 KV images and Mono_E images (P < 0.05). As for the subjective score, Mono+ 55 keV image score also had the highest score, which had statistical significance (P < 0.05). The results showed that Mono+ 55 keV images had the best quality. Conclusion: The new generation of virtual Mono+ post-treatment can reduce image noise. Low energy Mono+ images can improve the contrast between pancreatic cancer lesions and portal of pancreatic cancer patients.
文摘Purpose: To explore the significance of dual-source computed tomography (DECT) virtual monoenergetic reconstructions technology in improving the imaging quality of esophageal cancer patients. Materials and methods: 68 patients with clinically suspected esophageal cancer (all confirmed by pathology) were collected. Routine plain scan was performed with SIEMENS Force dual-energy CT and then dual-phase scans were performed. The venous phase images were respectively subjected to traditional virtual monoenergetic reconstructions (Mono_E) and new generation virtual monoenergetic reconstructions (Mono+). Mono_E 55 keV and Mono+ 55 keV virtual single-energy images were obtained respectively. The signal-to-noise ratio (SNR) of normal esophageal tissue and esophageal cancer lesions, noise and contrast noise ratio (CNR tumor) of normal esophageal tissue and esophageal cancer lesions were compared among 100 kV images, Mono_E images and Mono+ images. At the same time, two imaging physicians read the films and scored the images of each group by using a 5-point scoring method. Results: Mono+ 55 keV images, SNR, SNRtumor, noise and CNRtumor were statistically different from those of 100 kV images and Mono_E images (P < 0.05). And Mono+ 55 keV images also had the highest subjective score, with statistical significance (P 55 keV images had the best quality. Conclusion: The new generation of virtual monoenergetic reconstructions post-processing (Mono+) could reduce image noise and improve the contrast between esophageal cancer lesions and normal esophageal tissues, which was of great significance to improve the imaging quality of esophageal cancer patients and improve the early detection rate of esophageal cancer.
基金Project (No.2006BAI01A02) supported by the National Science and Technology Pillar Program of the 11th five-year Plan,China
文摘Objective: The aim of this study is to investigate if dual-source computed tomography (DSCT) could guide the percutaneous coronary intervention (PCI) of chronic total occlusion (CTO). Methods: We enrolled patients who were confirmed to have at least one native coronary artery CTO by DSCT before they underwent selective PCI in the period from December 2007 to October 2008. A CTO was defined as an obstruction of a native coronary artery with no luminal continuity. The CT-guided PCI procedure involved placing CT and fluoroscopic images side-by-side on the screen. DSCT images were analyzed for location, segment, plaque characteristics, calcification, and proximal lumen diameter of the CTO before PCI. The guidewire was advanced and manipulated under CT guidance. The PCI was carried out and the results were compared. Results: Seventy-four CTOs were assessed. PCI was successful in 57 cases of CTOs (77.0%). According to the results, CTOs were divided into two groups: successfuI-PCI and failed-PCI. All coronary artery paths of CTOs were clearly recognized by DSCT. In the successfuI-PCI group, soft plaques were detected much more often than those in the failed-PCI group, but fibrous and calcified plaques were seen more often in the failed-PCI group. Calcification severity in CTO segments showed a significant difference between the groups (P=0.014). Calcified plaques were detected in 20 (35.1%) lesions in the successfuI-PCI group. More than 70% of the failures were calcified plaques, of which there were two arc-calcified and one circular-calcified lesions. Occlusions were longer in the failed-PCI group than those in the successfuI-PCI group [(38.8±25.0) vs. (18.0±15.3) mm, respec- tively, P〈0.01]. Fewer guidewires were used in the successfuI-PCI group compared with the failed-PCI group (1.7±1.0 vs. 2.5±0.9, respectively, P〈0.01). The logistic regression analysis indicated that predictors of recanalization of CTOs included occlusion length (P=-0.0035, risk ratio (RR)=0.93) and calcification severity (P=0.05, RR=0.27). Multi-linear trends analysis showed that the factors affecting procedural time were CTO location (P=-0.0141) and occlusion length (P=0.0035). Conclusions: DSCT could delineate the path of CTOs and characterize plaques. The outcomes of PCI were related to thrombolysis in myocardial infarction (TIMI) flow grade, CTO characteristics, severity of calcified plaques and the length of occlusive segments. Occlusion length and calcification severity were independent predictors of CTOs. Occlusion length and CTO segments could also help to estimate the duration of interventional procedures.