期刊文献+
共找到14篇文章
< 1 >
每页显示 20 50 100
Non-enhanced Low-tube-voltage High-pitch Dual-source Computed Tomography with Sinogram Affirmed Iterative Reconstruction Algorithm of the Abdomen and Pelvis 被引量:3
1
作者 Hao Sun Hua-dan Xue +5 位作者 Zheng-yu Jin Xuan Wang Yu Chen Yong-lan He Da-ming Zhang Liang Zhu 《Chinese Medical Sciences Journal》 CAS CSCD 2014年第4期214-220,共7页
Objective To investigate the image quality, radiation dose and diagnostic value of the low-tube-voltage high-pitch dual-source computed tomography(DSCT) with sinogram affirmed iterative reconstruction(SAFIRE) for non-... Objective To investigate the image quality, radiation dose and diagnostic value of the low-tube-voltage high-pitch dual-source computed tomography(DSCT) with sinogram affirmed iterative reconstruction(SAFIRE) for non-enhanced abdominal and pelvic scans. Methods This institutional review board-approved prospective study included 64 patients who gave written informed consent for additional abdominal and pelvic scan with DSCT in the period from November to December 2012. The patients underwent standard non-enhanced CT scans(protocol 1) [tube voltage of 120 k Vp/pitch of 0.9/filtered back-projection(FBP) reconstruction] followed by high-pitch non-enhanced CT scans(protocol 2)(100 k Vp/3.0/SAFIRE). The total scan time, mean CT number, signal-to-noise ratio(SNR), image quality, lesion detectability and radiation dose were compared between the two protocols. Results The total scan time of protocol 2 was significantly shorter than that of protocol 1(1.4±0.1 seconds vs. 7.6±0.6 seconds, P<0.001). There was no significant difference between protocol 1 and protocol 2 in mean CT number of all organs(liver, 55.4±6.3 HU vs. 56.1±6.8 HU, P=0.214; pancreas, 43.6±5.9 HU vs. 43.7±5.8 HU, P=0.785; spleen, 47.9±3.9 HU vs. 49.4±4.3 HU, P=0.128; kidney, 32.2±2.3 HU vs. 33.1±2.3 HU, P=0.367; abdominal aorta, 44.8±5.6 HU vs. 45.0±5.5 HU, P=0.499; psoas muscle, 50.7±4.1 HU vs. 50.3±4.5 HU, P=0.279). SNR on images of protocol 2 was higher than that of protocol 1(liver, 5.0±1.2 vs. 4.5±1.1, P<0.001; pancreas, 4.0±1.0 vs. 3.6±0.8, P<0.001; spleen, 4.7±1.0 vs. 4.1±0.9, P<0.001; kidney, 3.1±0.6 vs. 2.8±0.6, P<0.001; abdominal aorta, 4.1±1.0 vs. 3.8±1.0, P<0.001; psoas muscle, 4.5±1.1 vs. 4.3±1.2, P=0.012). The overall image noise of protocol 2 was lower than that of protocol1(9.8±3.1 HU vs. 11.1±3.0 HU, P<0.001). Image quality of protocol 2 was good but lower than that of protocol 1(4.1±0.7 vs. 4.6±0.5, P<0.001). Protocol 2 perceived 229 of 234 lesions(97.9%) that were detected in protocol 1 in the abdomen and pelvis. Radiation dose of protocol 2 was lower than that of protocol 1(4.4±0.4 m Sv vs. 7.3±2.4 m Sv, P<0.001) and the mean dose reduction was 41.4%. Conclusion The high-pitch DSCT with SAFIRE can shorten scan time and reduce radiation dose while preserving image quality in non-enhanced abdominal and pelvic scans. 展开更多
关键词 high PITCH dual-source COMPUTED tomography iterative reconstruction imagequality radiation DOSE
在线阅读 下载PDF
Truncus arteriosus:Diagnosis with dual-source computed tomography angiography and low radiation dose 被引量:2
2
作者 Mustafa Koplay Derya Cimen +4 位作者 Mesut Sivri Osman Güvenc Derya Arslan Alaaddin Nayman Bulent Oran 《World Journal of Radiology》 CAS 2014年第11期886-889,共4页
Truncus arteriosus is an uncommon congenital cardiac abnormality which is characterized by a single arterial trunk origin from the heart that supplies both the systemic,pulmonary and coronary circulation.We present a ... Truncus arteriosus is an uncommon congenital cardiac abnormality which is characterized by a single arterial trunk origin from the heart that supplies both the systemic,pulmonary and coronary circulation.We present a preterm newborn female patient with type 2 truncusarteriosus,left superior vena cava and aberrant subclavian artery diagnosed with low dose dual-source cardiac computed tomography(CT).We discuss that low dose dual-source cardiac CT has more advantages than other imaging methods and it is an important modality for assessment of patients with conotruncal anomalies such as truncusarteriosus. 展开更多
关键词 Truncusarteriosus Type 2 dual-source computed tomography ANGIOGRAPHY Radiation dose
在线阅读 下载PDF
Assessment of Intracardiac and Extracardiac Deformities in Patients with Various Types of Pulmonary Atresia by Dual-Source Computed Tomography
3
作者 Wenlei Qian Xinzhu Zhou +4 位作者 Ke Shi Li Jiang Xi Liu Liting Shen Zhigang Yang 《Congenital Heart Disease》 SCIE 2023年第1期113-125,共13页
Background:Pulmonary atresia(PA)is a group of heterogeneous complex congenital heart disease.Only one study modality might not get a correct diagnosis.This study aims to investigate the diagnostic power of dualsource ... Background:Pulmonary atresia(PA)is a group of heterogeneous complex congenital heart disease.Only one study modality might not get a correct diagnosis.This study aims to investigate the diagnostic power of dualsource computed tomography(DSCT)for all intracardiac and extracardiac deformities in patients with PA compared with transthoracic echocardiography(TTE).Materials and Methods:This retrospective study enrolled 79 patients and divided them into three groups according to their main diagnosis.All associated malformations and clinical information,including treatments,were recorded and compared among the three groups.The diagnostic power of DSCT and TTE on all associated malformations were compared.The surgical index(McGoon ratio,pulmonary arterials index(PAI),and total neopulmonary arterial index)and radiation dose were calculated on the basis of DSCT.Results:Of the patients,32,30,and 17 were divided into the groups of PA with ventricular septal defect(VSD),PA with VSD and major aortopulmonary collateral arteries,and PA with other major malformations,respectively.Consequently,182,162,and 13 intracardiac,extracardiac,and other major malformations were diagnosed,respectively.Moreover,DSCT showed a better diagnostic performance in extracardiac deformities(154 vs.117,p<0.001),whereas TTE could diagnose intracardiac deformities better(159 vs.139,p=0.001).The McGoon ratio,PAI,and treatment methods were significantly different among the three groups(p=0.014,p=0.008,and p=0.018,respectively).Conclusion:More than one imaging modality should be used to make a correct diagnosis when clinically suspecting PA.DSCT is superior to TTE in diagnosing extracardiac deformities and could be used to roughly calculate surgical indices to optimize treatment strategy. 展开更多
关键词 Pulmonary atresia complex congenital heart diseases dual-source computed tomography transthoracic echocardiography
在线阅读 下载PDF
Feasibility and Diagnostic Accuracy for Assessment of Coronary Artery Stenosis of Prospectively Electrocardiogram-gated High-pitch Spiral Acquisition Mode Dual-source CT Coronary Angiography in Patients with Relatively Higher Heart Rates: in Comparison wit 被引量:4
4
作者 Kai Sun Rui-juan Han +5 位作者 Li-fang Cui Rui-ping Zhao Li-jun Ma Li-jun Wang Li-gang Li Chang-yong Li 《Chinese Medical Sciences Journal》 CAS CSCD 2012年第4期213-219,共7页
Objective To prospectively investigate the diagnostic accuracy for coronary artery stenosis of prospectively electrocardiogram-triggered spiral acquisition mode (high pitch mode) dual-source computed tomography corona... Objective To prospectively investigate the diagnostic accuracy for coronary artery stenosis of prospectively electrocardiogram-triggered spiral acquisition mode (high pitch mode) dual-source computed tomography coronary angiography (CTCA) in patients with relatively higher heart rates (HR) compared with catheter coronary angiography (CCA). Methods Forty-seven consecutive patients with relatively higher HR (>65 and <100 bpm) (20 male, 27 female; age 55±10 years) who both underwent dual-source CTCA and CCA were prospectively included in this study. All patients were performed CTCA using high pitch mode setting at 20%-30% of the R-R interval for the image acquisition. All coronary segments were evaluated by two blinded and independent observers with regard to image quality on a three-point scale (1: excellent to 3: non-diagnostic) and for the presence of significant coronary stenoses (defined as diameter narrowing exceeding 50%). Considered CCA as the standard of reference, the sensitivity, specificity, positive predictive value and negative predictive value were calculated. Radiation dose values were calculated using the dose-length product. Results Image quality was rated as being score 1 in 92.4% of segments, score 2 in 6.1% of segmentsand score 3 in 1.5% of segments. The average image quality score per segment was 1.064±0.306. The HR variability of patients with image score 1, 2 and 3 were 2.29±1.06 bpm, 5.17±1.37 bpm, 8.88±1.53 bpm, respectively. The average HR variability of patients with different image scores were significantly different (F=170.402, P=0.001). The sensitivity, specificity, positive and negative predictive values were 92.6%, 97.0%, 87.6%, 98.3%, respectively, per segment and 90.0%, 95.2%, 85.3%, 96.9%, respectively, per vessel and 100%, 63.6%, 90.0%, 100%, respectively, per patient. The effective radiation dose was on average 0.86±0.16 mSv. Conclusion In patients with HR more than 65 bpm and below 100 bpm without cardiac arrhythmia, the prospectively electrocardiogram-gated high-pitch spiral acquisition mode with image acquired timing set at 20%-30% of the R-R interval provides a high diagnostic accuracy for the assessment of coronary stenoses combined with a 1.5% of non-diagnostic coronary segments and a radiation dose below 1 mSv. 展开更多
关键词 dual-source computed tomography coronary angiography high pitch prospectively electrocardiogram-triggered spiral mode high heart rate diagnostic accuracy
在线阅读 下载PDF
Intravenous Contrast Material Administration at High-pitch Dual-source CT Coronary Angiography: Bolus-tracking Technique with Shortened Time of Respiratory Instruction Versus Test Bolus Technique 被引量:2
5
作者 Kai Sun Guo-rong Liu +5 位作者 Yue-chun Li Rui-juan Han Li-fang Cui Li-jun Ma Li-gang Li Chang-yong Li 《Chinese Medical Sciences Journal》 CAS CSCD 2012年第4期225-231,共7页
Objective To investigate the feasibility of acquiring the similar homogeneous enhancement using bolus-tracking techniques with shortened respiratory time in prospectively electrocardiogram-gated high-pitch spiral acqu... Objective To investigate the feasibility of acquiring the similar homogeneous enhancement using bolus-tracking techniques with shortened respiratory time in prospectively electrocardiogram-gated high-pitch spiral acquisition mode (Flash mode) coronary computed tomography angiography (CCTA) compared with test bolus technique. Methods One hundred and eighty-four consecutive patients with mean heart rate ≤65 beats per minute undergoing CCTA were prospectively included in this study. The patients were randomly divided into two groups. Patients in the group A (n=92) instructed to shorten respiratory time received CCTA using bolus-tracking technique with high-pitch spiral acquisition mode (Flash mode), while those in the group B (n=92) underwent CCTA with test bolus technique. The attenuation in the ascending aorta, image noise, contrast-to-noise ratio and radiation doses of the two groups were assessed. Results There were no significant differences in the mean attenuation values in the ascending aorta (483.18±59.07 HU vs. 498.7±83.51 HU, P=0.183), image noise (21.4±4.5 HU vs. 20.9±4.3 HU, P=0.414), contrast-to-noise ratio (12.1±4.2 vs. 13.8±5.1, P=0.31) between the groups A and B. There were no significant differences in the radiation dose of dynamic monitoring scans (0.056±0.026 mSv vs. 0.062±0.018 mSv, P=0.068) and radiation dose of angiography (0.94±0.07 mSv vs. 0.96±0.15 mSv,P=0.926) between the two groups, while 15 mL less contrast material volume was administered in the group A than the group B. Conclusion Bolus-tracking technique with shortened time of respiratory in Flash mode of dual-source CT yields the similar homogeneous enhancement with less contrast material in comparison to the test bolus technique. 展开更多
关键词 dual-source computed tomography coronary angiography contrastenhancement test bolus technique bolus-tracking technique
在线阅读 下载PDF
Head dual energy-computed tomography angiography versus neuro-digital subtraction angiography
6
作者 Dan Han Liang Wen Yan Xu 《Neural Regeneration Research》 SCIE CAS CSCD 2010年第24期1910-1914,共5页
Dual-energy X-ray absorptiometry provides two modes of head computed tomography (CT) angiography scanning: neuro-digital subtraction angiography and dual-energy CT angiography (DE-CTA). Previous studies have comp... Dual-energy X-ray absorptiometry provides two modes of head computed tomography (CT) angiography scanning: neuro-digital subtraction angiography and dual-energy CT angiography (DE-CTA). Previous studies have compared image quality, radiation exposure, and bone removal between neuro-digital subtraction angiography and DE-CTA. However, the number of cases was relatively small. The present study examined 300 suspected cases of cerebrovascular disease and observed the methods and duration of post-processing, examination time, and data volume. Results demonstrated similar image quality between the two methods, but lower radiation doses and shorter examination time in DE-CTA. DE-CTA allowed for faster and more stable scanning performance and post-processing methods, facilitating accurate and direct diagnosis of cerebrovascular disease. 展开更多
关键词 tomography X-ray computer dual-source computec/tomography DUAL-ENERGY neuro- digital subtraction angiography cerebral angiography neural regeneration
在线阅读 下载PDF
Dose Efficiency in Dual Source High-Pitch Computed Tomography of the Chest
7
作者 Boris Bodelle Thomas Lehnert +2 位作者 Martin Beeres Thomas Josef Vogl Boris Schulz 《Advances in Computed Tomography》 2014年第4期51-58,共8页
Objectives: Evaluation of radiation efficiency of dual source high-pitch (DSHP) chest CT in comparison to single source technique with special regards to individual patient anatomy. Methods: 150 consecutive patients w... Objectives: Evaluation of radiation efficiency of dual source high-pitch (DSHP) chest CT in comparison to single source technique with special regards to individual patient anatomy. Methods: 150 consecutive patients who underwent chest CT with automated tube current modulation were evaluated retrospectively and divided into three study groups, each with an equal quantity of 50 patients (DSHP vs. single source 128 slices vs. single source 16 slices). By using a dedicated workstation, volumetric analyses of each of the scanned anatomic area were performed and correlated to the individual dose length product (DLP). The calculated result was defined as dose efficiency. Results: DLP was 203 mGycm (DSHP), vs. 269 mGycm (single source) vs. 273 mGycm (16 slice CT). The total patient volume was lowest in the dual source group with 18956.3 cm3 (vs. 22481.2 cm3 vs. 22133.8 cm3). With regards to the DLP, the calculated dose efficiency of dual source CT was better than the 128 slice CT (p = 0.045) and the 16 slice CT (p < 0.01). Conclusions: DSHP CT has considerably better dose efficiency compared to 16 slice CT. Compared to 128 slice single source technique, the high-pitch mode does not cause any dose penalty when performing chest CT. 展开更多
关键词 COMPUTED tomography LUNG Radiation Exposure Imaging dual-source
在线阅读 下载PDF
Diagnostic Value of Prospective Electrocardiogram-triggered Dual-source Computed Tomography Angiography for Infants and Children with Interrupted Aortic Arch
8
作者 Hai-Ou Li Xi-Ming Wang +4 位作者 Pei Nie Xiao-Peng Ji Zhao-Ping Cheng Jiu-Hong Chen Zhuo-Dong Xu 《Chinese Medical Journal》 SCIE CAS CSCD 2015年第9期1184-1189,共6页
Background:Accurate assessment of intra-as well as extra-cardiac malformations and radiation dosage concerns are especially crucial to infants and children with interrupted aortic arch (IAA).The purpose of this stu... Background:Accurate assessment of intra-as well as extra-cardiac malformations and radiation dosage concerns are especially crucial to infants and children with interrupted aortic arch (IAA).The purpose of this study is to investigate the value of prospective electrocardiogram (ECG)-triggered dual-source computed tomography (DSCT) angiography with low-dosage techniques in the diagnosis of IAA.Methods:Thirteen patients with suspected IAA underwent prospective ECG-triggered DSCT scan and transthoracic echocardiography (TTE).Surgery was performed on all the patients.A five-point scale was used to assess image quality.The diagnostic accuracy ofDSCT angiography and TTE was compared with the surgical findings as the reference standard.A nonparametric Chi-square test was used for comparative analysis.P<0.05 was considered as a significant difference.The mean effective radiation dose (ED) was calculated.Results:Diagnostic DSCT images were obtained for all the patients.Thirteen IAA cases with 60 separate cardiovascular anomalies were confirmed by surgical findings.The diagnostic accuracy of TTE and DSCT for total cardiovascular malformations was 93.7% and 97.9% (P>0.05),and that for extra-cardiac vascular malformations was 92.3% and 99.0% (P < 0.05),respectively.The mean score of image quality was 3.77 ± 0.83.The mean ED was 0.30 ± 0.04 mSv (range from 0.23 mSv to 0.39 mSv).Conclusions:In infants and children with IAA,prospective ECG-triggered DSCT with low radiation exposure and high diagnostic efficiency has higher accuracy compared to TTE in detection of extra-cardiac vascular anomalies. 展开更多
关键词 dual-source Computed tomography Image Quality Interrupted Aortic Arch Prospective ECG-triggered Radiation Dose
原文传递
双源CT血管成像评估冠状动脉异常起源的价值 被引量:9
9
作者 刘明 虞崚崴 +2 位作者 张玉珍 张永平 李玉华 《放射学实践》 北大核心 2010年第7期757-760,共4页
目的:探讨双源CT血管成像对冠状动脉异常起源的诊断价值。方法:对8375例成人冠状动脉双源CT血管成像中109例显示为冠状动脉异常起源的图像进行回顾性分析。结果:本组中冠状动脉起源异常检出率为1.3%(109/8375),包括左侧冠状动脉起源异... 目的:探讨双源CT血管成像对冠状动脉异常起源的诊断价值。方法:对8375例成人冠状动脉双源CT血管成像中109例显示为冠状动脉异常起源的图像进行回顾性分析。结果:本组中冠状动脉起源异常检出率为1.3%(109/8375),包括左侧冠状动脉起源异常37例(窦上开口4例,窦后开口4例,回旋支异位开口于右侧冠状窦8例,回旋支独立开口于左冠状窦15例,左冠开口于右冠状窦或右冠状动脉4例,左冠开口于肺动脉1例,回旋支缺如1例),右侧冠状动脉起源异常61例(高位开口29例,异位开口于左冠状窦24例,圆锥支独立开口8例),左、右冠状动脉均起源异常11例;109例起源异常中发现伴随冠状动脉肺动脉瘘2例,心肌桥4例。结论:双源CT可以准确诊断冠状动脉起源异常,并可发现其它伴随病变,是一种无创有效的检查方法。 展开更多
关键词 体层摄影术 X线计算机 血管造影术 冠状动脉 变异
在线阅读 下载PDF
64层螺旋CT对冠状动脉异常起源的诊断价值 被引量:2
10
作者 杨晓光 刘挨师 +2 位作者 吕铁钢 郝粉娥 王大鹏 《内蒙古医科大学学报》 2013年第01S期19-23,共5页
目的:探讨64层螺旋CT冠状动脉造影诊断先天性冠状动脉起源异常的临床价值。材料与方法回顾性分析2011-06~2011-12行64层螺旋CT冠状动脉血管成像的1000例病人的CTA图像,对图像分别行多平面重建(MPR)、最大密度投影(MIP)和容积重现(VR)... 目的:探讨64层螺旋CT冠状动脉造影诊断先天性冠状动脉起源异常的临床价值。材料与方法回顾性分析2011-06~2011-12行64层螺旋CT冠状动脉血管成像的1000例病人的CTA图像,对图像分别行多平面重建(MPR)、最大密度投影(MIP)和容积重现(VR)法重建图像,并对结果进行分析、总结。结果:1000例完整冠状动脉CTA结果中,诊断冠状动脉先天性异常起源者共36例,发生率为3.6%。其中男16例,女20例,年龄36~74岁,平均52.2岁。其中左冠优势型2例,均衡型5例,右冠优势型29例。发现的冠状动脉起源异常种类有:右冠状动脉变异12例(33.3%);左冠状动脉变异19例(52.8%);冠状动脉其他分支起源异常5例(13.9%)。所有图像通过不同的重建方法可以清晰直观地显示异常血管的起始和行程。结论:64层螺旋CT冠状动脉成像可清晰显示冠状动脉异常起源,可为心血管医师提供有价值的影像,为一种无创、安全、有效的检查方法。 展开更多
关键词 体层摄影术 X线计算机 血管造影术 冠状动脉 变异
在线阅读 下载PDF
Diagnostic value of dual-source CT in Kawasaki disease 被引量:8
11
作者 CHAO Bao-ting WANG Xi-ming WULe-bin CHEN Jie CHENG Zhao-ping WU Da-wei DUAN Yan-hua 《Chinese Medical Journal》 SCIE CAS CSCD 2010年第6期670-674,共5页
Background Doppler color echocardiography is a common method for detecting coronary artery lesions in patients with Kawasaki disease(KD).However,the diagnostic accuracy for the whole coronary artery lesions is limit... Background Doppler color echocardiography is a common method for detecting coronary artery lesions in patients with Kawasaki disease(KD).However,the diagnostic accuracy for the whole coronary artery lesions is limited.The purpose of this study was to compare the diagnostic value of dual-source computed tomography (DSCT) and Doppler color echocardiography for the assessment of coronary artery lesions caused by KD.Methods Sixteen patients,12 with typical KD and 4 with atypical KD,underwent DSCT and Doppler color echocardiography.The position and internal diameter of each coronary artery lesion was measured.Correlation analysis was used to compare the diagnostic value of the two imaging modalities.Results ln the typical KD group, seven patients did not have any coronary artery Iesion as confirmed by both DSCT scans and Doppler color echocardiography;in four patients proximal coronary artery injuries were identified by both modalities;in one patient an aneurysm in the middle and distal segments of the coronary artery was detected by DSCT but was negative in Doppler color echocardiography.In the atypical KD group,three cases showed the same results with both modalities,while one case with coronary artery stenosis in the middle segment was identified by DSCT but not detected by Doppler color echocardiography.There was a good correlation between the two imaging modalities(Kappa value,0.768(≥0.75)).Conclusion DSCT coronary artery angiography is an accurate,non-invasive,and valuable technique for detecting and following up coronary artery lesions in patients with KD. 展开更多
关键词 dual-source computed tomography Kawasaki disease coronary artery
原文传递
Significance of an Advanced Image-Based Virtual Monoenergetic Reconstruction of Dual Source Dual-Energy CT Data at Low keV Increases Image Quality for Portal Vein System of Pancreatic Cancer Patients
12
作者 Shuiqing Zhuo Sihui Zeng +1 位作者 Jingping Yu Lizhi Liu 《Journal of Cancer Therapy》 2018年第10期827-837,共11页
Purpose: To explore the significance of dual-source computed tomography (DECT) virtual monoenergetic reconstructions technology in improving image quality for portal vein system of pancreatic cancer patients. Material... Purpose: To explore the significance of dual-source computed tomography (DECT) virtual monoenergetic reconstructions technology in improving image quality for portal vein system of pancreatic cancer patients. Materials and methods: 47 patients with clinically suspected pancreatic cancer (all confirmed by pathology) were collected. Routine plain scan was performed with Siemens Force dual-source dual-energy CT followed by 3 scans respectively carried out in arterial phase, portal phase and delayed phase. Traditional virtual monoenergetic reconstructions (Mono_E) and new generation of virtual monoenergetic reconstructions (Mono+) were respectively performed on portal vein images to obtain virtual single energy images including Mono_ E70 keV, Mono_E 55 keV and Mono+ 70 keV and Mono+ 55 keV. The signal-to-noise ratio (SNR) and noise of portal vein, normal pancreatic tissues and pancreatic lesions of 100 kV, Mono_E and Mono+ images were compared. In addition, the contrast noise ratio of portal vein and lesions as well as pancreatic tissues and lesions (CNR PV, CNRtumor) were also compared. At the same time, two imaging physicians with rich clinical experiences read the films and scored the images of each group by using the 5-point scoring method. Results: Mono+ 55 keV images including SNRpv, SNRpanc, SNRtumor, Noise, CNRpv, CNRtumor were statistically different from 100 KV images and Mono_E images (P < 0.05). As for the subjective score, Mono+ 55 keV image score also had the highest score, which had statistical significance (P < 0.05). The results showed that Mono+ 55 keV images had the best quality. Conclusion: The new generation of virtual Mono+ post-treatment can reduce image noise. Low energy Mono+ images can improve the contrast between pancreatic cancer lesions and portal of pancreatic cancer patients. 展开更多
关键词 dual-source VIRTUAL Monoenergetic RECONSTRUCTIONS Computed tomography PANCREATIC Tumors Portal VEIN SYSTEM CT Angiography Image Quality
在线阅读 下载PDF
Application of an Advanced Image-Based Virtual Monoenergetic Reconstruction of Dual Source Dual-Energy CT Data at Low keV Increases Image Quality for Esophageal Cancer Patients Imaging
13
作者 Shuiqing Zhuo Xiaoling Chen +2 位作者 Jingping Yu Jian Zhou Chuanmiao Xie 《Open Journal of Medical Imaging》 2018年第3期81-88,共8页
Purpose: To explore the significance of dual-source computed tomography (DECT) virtual monoenergetic reconstructions technology in improving the imaging quality of esophageal cancer patients. Materials and methods: 68... Purpose: To explore the significance of dual-source computed tomography (DECT) virtual monoenergetic reconstructions technology in improving the imaging quality of esophageal cancer patients. Materials and methods: 68 patients with clinically suspected esophageal cancer (all confirmed by pathology) were collected. Routine plain scan was performed with SIEMENS Force dual-energy CT and then dual-phase scans were performed. The venous phase images were respectively subjected to traditional virtual monoenergetic reconstructions (Mono_E) and new generation virtual monoenergetic reconstructions (Mono+). Mono_E 55 keV and Mono+ 55 keV virtual single-energy images were obtained respectively. The signal-to-noise ratio (SNR) of normal esophageal tissue and esophageal cancer lesions, noise and contrast noise ratio (CNR tumor) of normal esophageal tissue and esophageal cancer lesions were compared among 100 kV images, Mono_E images and Mono+ images. At the same time, two imaging physicians read the films and scored the images of each group by using a 5-point scoring method. Results: Mono+ 55 keV images, SNR, SNRtumor, noise and CNRtumor were statistically different from those of 100 kV images and Mono_E images (P < 0.05). And Mono+ 55 keV images also had the highest subjective score, with statistical significance (P 55 keV images had the best quality. Conclusion: The new generation of virtual monoenergetic reconstructions post-processing (Mono+) could reduce image noise and improve the contrast between esophageal cancer lesions and normal esophageal tissues, which was of great significance to improve the imaging quality of esophageal cancer patients and improve the early detection rate of esophageal cancer. 展开更多
关键词 dual-source DUAL-ENERGY VIRTUAL Monoenergetic RECONSTRUCTIONS COMPUTED tomography ESOPHAGEAL Cancer
在线阅读 下载PDF
Computed tomography angiography-guided percutaneous coronary intervention in chronic total occlusion 被引量:7
14
作者 Ping LI Lu-yue GAI Xia YANG Zhi-jun SUN Qin-hua JIN 《Journal of Zhejiang University-Science B(Biomedicine & Biotechnology)》 SCIE CAS CSCD 2010年第8期568-574,共7页
Objective: The aim of this study is to investigate if dual-source computed tomography (DSCT) could guide the percutaneous coronary intervention (PCI) of chronic total occlusion (CTO). Methods: We enrolled pati... Objective: The aim of this study is to investigate if dual-source computed tomography (DSCT) could guide the percutaneous coronary intervention (PCI) of chronic total occlusion (CTO). Methods: We enrolled patients who were confirmed to have at least one native coronary artery CTO by DSCT before they underwent selective PCI in the period from December 2007 to October 2008. A CTO was defined as an obstruction of a native coronary artery with no luminal continuity. The CT-guided PCI procedure involved placing CT and fluoroscopic images side-by-side on the screen. DSCT images were analyzed for location, segment, plaque characteristics, calcification, and proximal lumen diameter of the CTO before PCI. The guidewire was advanced and manipulated under CT guidance. The PCI was carried out and the results were compared. Results: Seventy-four CTOs were assessed. PCI was successful in 57 cases of CTOs (77.0%). According to the results, CTOs were divided into two groups: successfuI-PCI and failed-PCI. All coronary artery paths of CTOs were clearly recognized by DSCT. In the successfuI-PCI group, soft plaques were detected much more often than those in the failed-PCI group, but fibrous and calcified plaques were seen more often in the failed-PCI group. Calcification severity in CTO segments showed a significant difference between the groups (P=0.014). Calcified plaques were detected in 20 (35.1%) lesions in the successfuI-PCI group. More than 70% of the failures were calcified plaques, of which there were two arc-calcified and one circular-calcified lesions. Occlusions were longer in the failed-PCI group than those in the successfuI-PCI group [(38.8±25.0) vs. (18.0±15.3) mm, respec- tively, P〈0.01]. Fewer guidewires were used in the successfuI-PCI group compared with the failed-PCI group (1.7±1.0 vs. 2.5±0.9, respectively, P〈0.01). The logistic regression analysis indicated that predictors of recanalization of CTOs included occlusion length (P=-0.0035, risk ratio (RR)=0.93) and calcification severity (P=0.05, RR=0.27). Multi-linear trends analysis showed that the factors affecting procedural time were CTO location (P=-0.0141) and occlusion length (P=0.0035). Conclusions: DSCT could delineate the path of CTOs and characterize plaques. The outcomes of PCI were related to thrombolysis in myocardial infarction (TIMI) flow grade, CTO characteristics, severity of calcified plaques and the length of occlusive segments. Occlusion length and calcification severity were independent predictors of CTOs. Occlusion length and CTO segments could also help to estimate the duration of interventional procedures. 展开更多
关键词 dual-source computed tomography (DSCT) Chronic total occlusion (CTO) ANGIOGRAPHY RECANALIZATION
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部