Objective Recombinase-aided polymerase chain reaction(RAP)is a sensitive,single-tube,two-stage nucleic acid amplification method.This study aimed to develop an assay that can be used for the early diagnosis of three t...Objective Recombinase-aided polymerase chain reaction(RAP)is a sensitive,single-tube,two-stage nucleic acid amplification method.This study aimed to develop an assay that can be used for the early diagnosis of three types of bacteremia caused by Staphylococcus aureus(SA),Pseudomonas aeruginosa(PA),and Acinetobacter baumannii(AB)in the bloodstream based on recombinant human mannanbinding lectin protein(M1 protein)-conjugated magnetic bead(M1 bead)enrichment of pathogens combined with RAP.Methods Recombinant plasmids were used to evaluate the assay sensitivity.Common blood influenza bacteria were used for the specific detection.Simulated and clinical plasma samples were enriched with M1 beads and then subjected to multiple recombinase-aided PCR(M-RAP)and quantitative PCR(qPCR)assays.Kappa analysis was used to evaluate the consistency between the two assays.Results The M-RAP method had sensitivity rates of 1,10,and 1 copies/μL for the detection of SA,PA,and AB plasmids,respectively,without cross-reaction to other bacterial species.The M-RAP assay obtained results for<10 CFU/mL pathogens in the blood within 4 h,with higher sensitivity than qPCR.M-RAP and qPCR for SA,PA,and AB yielded Kappa values of 0.839,0.815,and 0.856,respectively(P<0.05).Conclusion An M-RAP assay for SA,PA,and AB in blood samples utilizing M1 bead enrichment has been developed and can be potentially used for the early detection of bacteremia.展开更多
Rice blast is one of the important diseases in major rice producing areas of China. The main blast resistance genes Pi-ta and Pi-b showed broad-spectrum and durable resistance to rice blast in many rice growing areas ...Rice blast is one of the important diseases in major rice producing areas of China. The main blast resistance genes Pi-ta and Pi-b showed broad-spectrum and durable resistance to rice blast in many rice growing areas of China, which have been widely utilized in rice breeding and commercial production. In this study, on the basis of detection and verification of the genotypes of 22 rice varieties har- boring known blast resistance genes (Pi-ta and Pi-b) and blast susceptibility genes (pi-ta and pi-b), two multiple PCR systems for these genes were established by us- ing the functional markers of blast resistance genes Pi-ta and Pi-b as well as blast susceptibility genes pi-ta and pi-b, respectively. Specifically, multiple PCR system I could simultaneously detect blast resistance genes Pi-ta and Pi-b, while system II could detect simultaneously blast susceptibility genes pi-ta and pi-b. In addition, the genotypes of 336 high generation breeding materials were detected with these two multiple PCR systems. The results were highly consistent with those of conventional single mark detection, indicating that these two multiplex PCR systems were stable, reliable and time-saving. The established multiplex PCR systems may serve as a rapid and efficient method to identify and screen rice germplasm resources and can be applied in marker-assisted selection to polymerize multiple genes for blast resis- tance in rice breeding.展开更多
Objectives: To compare multiplex fluorescent PCRwith serum type-specific antibody detection in thediagnosis of herpes simplex virus (HSV) infection andto evaluate its significance in the diagnosis of genitalherpes.Met...Objectives: To compare multiplex fluorescent PCRwith serum type-specific antibody detection in thediagnosis of herpes simplex virus (HSV) infection andto evaluate its significance in the diagnosis of genitalherpes.Methods: We detected HSV infection in 121 speci-mens collected from patients with genital herpesusing both multiplex fluorescent PCR and serum type-specific antibody detection. HSV viral isolation wasused as the standard control.Results: When compared with the viral isolation, thesensitivity and specificity for multiplex fluorescentPCR were 100% and 88.89%, respectively afterdiscrepant analysis. The sensitivity and specificity fortype-specific antibody detection was 77.68 % and77.78 %, respectively. However, the type-specificantibody detected HSV in two asymptomatic patientswhile the multiplex fluorescent PCR couldn’t detectany HSV DNA from those specimens.Conclusions: Multiplex fluorescent PCR is a verysensitive and specific method for detection and typingof HSV in the lesion of genital herpes, it failed todetect HSV DNA from the asymptomatic patients.Serum type-specific antibody detection was a lesssensitive and specific test but could detect the specificantibody from some asymptomatic patients. Thecombination of these two techniques would allow rapid,sensitive and accurate detection and typing of HSVand help clinical diagnosis and epidemiologic survey-ing of genital herpes.展开更多
BACKGROUND Influenza A and B virus detection is pivotal in epidemiological surveillance and disease management.Rapid and accurate diagnostic techniques are crucial for timely clinical intervention and outbreak prevent...BACKGROUND Influenza A and B virus detection is pivotal in epidemiological surveillance and disease management.Rapid and accurate diagnostic techniques are crucial for timely clinical intervention and outbreak prevention.Quantum dot-encoded microspheres have been widely used in immunodetection.The integration of quantum dot-encoded microspheres with flow cytometry is a well-established technique that enables rapid analysis.Thus,establishing a multiplex detection method for influenza A and B virus antigens based on flow cytometry quantum dot microspheres will help in disease diagnosis.AIM To establish a codetection method of influenza A and B virus antigens based on flow cytometry quantum dot-encoded microsphere technology,which forms the foundation for the assays of multiple respiratory virus biomarkers.METHODS Different quantum dot-encoded microspheres were used to couple the monoclonal antibodies against influenza A and B.The known influenza A and B antigens were detected both separately and simultaneously on a flow cytometer,and the detection conditions were optimized to establish the influenza A and B antigen codetection method,which was utilized for their detection in clinical samples.The results were compared with the fluorescence quantitative polymerase chain reaction(PCR)method to validate the clinical performance of this method.RESULTS The limits of detection of this method were 26.1 and 10.7 pg/mL for influenza A and B antigens,respectively,which both ranged from 15.6 to 250000 pg/mL.In the clinical sample evaluation,the proposed method well correlated with the fluorescent quantitative PCR method,with positive,negative,and overall compliance rates of 57.4%,100%,and 71.6%,respectively.CONCLUSION A multiplex assay for quantitative detection of influenza A and B virus antigens has been established,which is characterized by high sensitivity,good specificity,and a wide detection range and is promising for clinical applications.展开更多
Objective To develop a technique for simultaneous detection of various target genes in Roundup Ready soybean by combining multiplex PCR and low-density DNA microarray. Methods Two sets of the multiplex PCR system were...Objective To develop a technique for simultaneous detection of various target genes in Roundup Ready soybean by combining multiplex PCR and low-density DNA microarray. Methods Two sets of the multiplex PCR system were used to amplify the target genes in genetically modified (GM) soybean. Seventeen capture probes (PCR products) and 17 pairs of corresponding primers were designed according to the genetic characteristics of Rroundup Ready soybean (GTS40-3-2), maize (MonS10, Nk603, GA21), canola (T45, MS1/RF1), and rice (SCK) in many identified GM crops. All of the probes were categorized and identified as species-specific probes. One negative probe and one positive control probe were used to assess the efficiency of all reactions, and therefore eliminate any false positive and negative results. After multiplex PCR reaction, amplicons were adulterated with Cy5-dUTP and hybridized with DNA microarray. The array was then scanned to display the specific hybridization signals of target genes. The assay was applied to the analysis of sample of certified transgenic soybean (Roundup Ready GTS40-3-2) and canola (MS1/RF1). Results A combination technique of multiplex PCR and DNA microarray was successfully developed to identify multi-target genes in Roundup Ready soybean and MS 1/RF1 canola with a great specificity and reliability. Reliable identification of genetic characteristics of Roundup Ready of GM soybean from genetically modified crops was achieved at 0.5% transgenic events, indicating a high sensitivity. Conclusion A combination technique of multiplex PCR and low-density DNA microarray can reliably detect and identify the genetically modified crops.展开更多
Objective Lower respiratory tract infections continue to pose a significant threat to human health. It is important to accurately and rapidly detect respiratory bacteria. To compensate for the limits of current respir...Objective Lower respiratory tract infections continue to pose a significant threat to human health. It is important to accurately and rapidly detect respiratory bacteria. To compensate for the limits of current respiratory bacteria detection methods, we developed a combination of multiplex polymerase chain reaction (PCR) and capillary electrophoresis (MPCE) assay to detect thirteen bacterial pathogens responsible for lower respiratory tract infections, including Streptococcus pneumoniae, Haemophilus influenzae, Moraxella catorrholis, Pseudomonas aeruginosa, Klebsiella pneumoniae, Escherichia coli, Staphylococcus aureus, Mycoplasma pneumoniae, Legionella spp., Bordetella pertussis, Mycobacterium tuberculosis complex, Corynebactefium diphthefiae, and Streptococcus pyogenes. Methods Three multiplex PCR reactions were built, and the products were analyzed by capillary electrophoresis using the high-throughput DNA analyzer. The specificity of the MPCE assay was examined and the detection limit was evaluated using DNA samples from each bacterial strain and the simulative samples of each strain. This assay was further evaluated using 152 clinical specimens and compared with real-time PCR reactions. For this assay, three nested-multiplex-PCRs were used to detect these clinical specimens. Results The detection limits of the MPCE assay for the 13 pathogens were very low and ranged from 10-7 to 10-2 ng/μL. Furthermore, analysis of the 252 clinical specimens yielded a specificity ranging from 96.5%-100.0%, and a sensitivity of 100.0% for the 13 pathogens. Conclusion This study revealed that the MPCE with high specificity and sensitivity. This assay survey of respiratory pathogens. assay is a rapid, reliable, and high-throughput method has great potential in the molecular epidemiological.展开更多
Objective To establish multiplex PCR-based assays for detecting H.influenzae and H.parainfluenzae. And the PCR-based assays were applied to detect the carriage rates of H.influenzae and H.parainfluenzae in nasopharyng...Objective To establish multiplex PCR-based assays for detecting H.influenzae and H.parainfluenzae. And the PCR-based assays were applied to detect the carriage rates of H.influenzae and H.parainfluenzae in nasopharyngeal swab specimens which were collected from healthy children. Methods Multiplex primers for species-specific PCR were designed by using DNAstar soft based on the sequences of 165 rRNA genes from genus Haemophilus to detect H.influenzae and H.parainfluenzae. Results The sensitivity of the 165 rRNA PCR assay for detecting H.influenzae and H.parainfluenzae was 97.53% and 100% respectively, and the specificity was 95.89% and 96.63% respectively. Youden's Index on the ability to detect H.influenzae and H.parainfluenzae was 0.9342 and 0.9663 respectively. 666 nasopharyngeal swab specimens were collected from healthy children. The detection rates of H.influenzae and H.parainfluenzae were 14.11% and 16.07% respectively by using isolation and culture methods. The detection rates of H.influenzae and H.parainfluenzae were 43.54% and 57.96% respectively by 165 rRNA PCR assays. The carriage rates of serotypes a, b, c, d, e, f and non-typeable isolates were 0% (0/666), 0.15% (1/666), 1.20% (8/666), 0.15% (1/666), 1.20% (8/666), 1.80% (12/666), 95.50% (636/666) respectively. Conclusion The multiplex PCR assays were very rapid, reliable and feasible methods for detection of H.influenzae and H.parainfluenzae in pharyngeal swab specimens which were compared to conventional isolation and culture methods. 95.5% of H.influenzae strains in healthy children were nontypeable. The encapsulated or typable strains were mainly three serotypes which was c, e, and f serotype.展开更多
PCRs based on different genes of Actinobacillus pleuropneumoniae have been developed for detecting and identifying A. pleuropneumoniae. Some of them could amplify positive fragments from the phylogenetically closely r...PCRs based on different genes of Actinobacillus pleuropneumoniae have been developed for detecting and identifying A. pleuropneumoniae. Some of them could amplify positive fragments from the phylogenetically closely related species bacteria. To improve veracity and specificity of PCR, a species-specific multiplex PCR assay was developed to identify and detect A. pleuropneumoniae, based on the 3'-terminus of the species-specific apxlVA gene and the already existing species-specific primers in the omlA gene. Both 346-bp and 950-bp fragments could be simultaneously amplified from all A. pleuropneumoniae reference strains and isolates, and the species specificity of the assay was evaluated with a collection of ten strains representing eight different species bacteria including species normally found in the respiratory tracts of swine. All of these strains turned out negative in the multiplex PCR. All sequences of products of multiplex PCR randomly sampled were also correct. The sensitivity of the multiplex PCR was determined to be 10 pg of A. pleuropneumoniae DNA. The multiplex PCR and bacterial isolation were compared to determine their sensitivities by using experimentally infected pigs and clinical disease pigs. The multiplex PCR was more sensitive than bacterial isolation. The multiplex PCR was also evaluated on mixed bacterial cultures from clinical healthy pigs. 26/100 (26%) of the subclinically infected pigs were detected from clinical healthy pigs. The results indicate that the multiplex PCR assay is a sensitive, highly specific, and effective diagnostic tool for identification and detection of A. pleuropneumoniae.展开更多
Objective:To study virulence and regulatory genes(hlyA,ctxB,tcpI) in clinical strains of Vibrio ckolerae(V.cholerae),simultaneously.Methods:Three important genes,tepI,hlyA and ctxB were used for detection of toxigenic...Objective:To study virulence and regulatory genes(hlyA,ctxB,tcpI) in clinical strains of Vibrio ckolerae(V.cholerae),simultaneously.Methods:Three important genes,tepI,hlyA and ctxB were used for detection of toxigenic and pathogenic V.cholera by chain reaction assay method. Results:According to the results of the PCR,the incidence of hlyA,tcpI,and ctxB genes in clinical isolates was obtained as 94.7%(72 sample),90.8%(69 sample),and 92.1%(70 sample), respectively.Five strains possessed all genes except ctxB,six strains possessed all genes except tcpI,four strains possessed all genes except hlyA,one strain possessed only hlyA and 60 strains contained a combination of three genes.Including hlyA,ctxB and tcpI,Conclusions:Result show that this method could be reliable to detect toxigenic-pathogenic strains of V.cholerae in Iran.展开更多
Objective This study is aimed to develop a two-tube melting curve-based multiplex real time PCR assay (MCMRT-PCR) for the simultaneous detection of six common foodborne pathogenic bacteria (diarrhoeagenic Escherich...Objective This study is aimed to develop a two-tube melting curve-based multiplex real time PCR assay (MCMRT-PCR) for the simultaneous detection of six common foodborne pathogenic bacteria (diarrhoeagenic Escherichia coli, Salmonella, and 5higella in tube 1, Staphylococcus aureus, Vibrio parahaemolyticus, and Listeria monocytogenes in tube 2). Methods A two-tube MCMRT-PCR assay was performed on 7900HT Fast Real-Time PCR System {Applied Biosystems, USA). Amplification by PCR was optimized to obtain high efficiency. The sensitivity and specificity of assays were investigated. Results The detection limit of optimized MCMRT-PCR assay was 3.9x102 CFU/mLfor S. aureus, 4.4x102 CFU/mL for L. monocytogenes, 3.0x102 CFU/mL for Salmonella, 2.5x102 CFU/mL for Shigella, 2.1x102 CFU/mL for V. parahaemolyticus, and 1.2x102 CFU/mL for E. coll. The feasibility of MCMRT-PCR was further evaluated using artificially contaminated milk, the sensitivity was at the level of 10s CFU/mL. Conclusion A two-tube MCMRT-PCR assay using six primer sets was developed for detection of multiple pathogens. Our findings demonstrates that the proposed two-tube assay is reliable, useful and rapid for simultaneous detection of six foodborne pathogenic bacteria with an intended application in provincial Centers for Diseases Control and Prevention (CDC).展开更多
Objective:To evaluate microscopy,OptiMAL<sup>?</sup> and multiplex PCR for the identification of Plasmodium falciparum(P.falciparum) and Plasmodium vivax(P.vivax) from the field isolates of Bikaner,Raj...Objective:To evaluate microscopy,OptiMAL<sup>?</sup> and multiplex PCR for the identification of Plasmodium falciparum(P.falciparum) and Plasmodium vivax(P.vivax) from the field isolates of Bikaner,Rajasthan(Northwest India).Methods:In this study,a multiplex PCR(P.falciparum and P.vivax) was further developed with the incorporation of Plasmodium malariae(P.malariae) specific primer and also a positive control.The performance of microscopy,plasmodium lactate dehydrogenase(pLDH) based malaria rapid diagnostic test OptiMAL<sup>?</sup> and 18S rRNA gene based multiplex PCR for the diagnosis of P.falciparum and P.vivax was compared.Results:The three species multiplex PCR if.falciparum,P.vivax and P.malariae) with an inbuilt positive control was developed and evaluated.In comparison with multiplex PCR,which showed the sensitivity and specificity of 99.36%(95%CI,98.11%-100.00%) and 100.00%(95%CI,100.00%-100.00%),the sensitivity and specificity of microscopy was 90.44%(95%CI,88.849-95.04%) and 99.22%(95% CI,97.71%-100.00%),and OptiMAL<sup>?</sup> was 93.58%(95%CI,89.75%-97.42%) and 97.69%(95%CI, 95.10%-100.00%).The efficiencies were 99.65%,95.10%and 95.45%for multiplex PCK.microscopy and OptiMAL<sup>?</sup>.respectively.Conclusions:Our results raise concerns over the overall sensitivities of microscopy and OptiMAL<sup>?</sup>,when compared to the multiplex PCR and thus stress the need for new molecular interventions in the accurate detection of the malarial parasites.This further highlights the fact that further developments are needed to improve the performance of rapid diagnostic tests at field level.展开更多
In marker-assisted breeding for bacterial blight(BB) resistance in rice, three major resistance genes, viz., Xa21, xa13 and xa5, are routinely deployed either singly or in combinations. As efficient and functional mar...In marker-assisted breeding for bacterial blight(BB) resistance in rice, three major resistance genes, viz., Xa21, xa13 and xa5, are routinely deployed either singly or in combinations. As efficient and functional markers are yet to be developed for xa13 and xa5, we have developed simple PCR-based functional markers for both the genes. For xa13, we designed a functional PCR-based marker, xa13-prom targeting the In Del polymorphism in the promoter of candidate gene Os8N3 located on chromosome 8 of rice. With respect to xa5, a multiplex-PCR based functional marker system, named xa5 FM, consisting of two sets of primer pairs targeting the 2-bp functional nucleotide polymorphism in the exon II of the gene TFIIA5(candidate for xa5), has been developed. Both xa13-prom and xa5 FM can differentiate the resistant and susceptible alleles for xa13 and xa5, respectively, in a co-dominant fashion. Using these two functional markers along with the already reported functional PCR-based marker for Xa21(p TA248), we designed a single-tube multiplex PCR based assay for simultaneous detection of all the three major resistance genes and demonstrated the utility of the multiplex marker system in a segregating population.展开更多
Objective:To analyse molecular detection of coliforms and shorten the time of PCR.Methods:Rapid detection of coliforms by amplification of lacZ and uidA genes in a multiplex PCR reaction was designed and performed in ...Objective:To analyse molecular detection of coliforms and shorten the time of PCR.Methods:Rapid detection of coliforms by amplification of lacZ and uidA genes in a multiplex PCR reaction was designed and performed in comparison with most probably number(MPN)method for 16 artificial and 101 field samples.The molecular method was also conducted on isolated coliforms from positive MPN samples;standard sample for verification of microbial method certificated reference material;isolated strains from certificated reference material and standard bacteria.The PCR and electrophoresis parameters were changed for reducing the operation time.Results:Results of PCR for lacZ and uidA genes were similar in all of standard,operational and artificial samples and showed the 876 bp and 147 bp bands of lacZ and uidA genes by multiplex PCR.PCR results were confirmed by MPN culture method by sensitivity 86%(95%CI:0.71-0.93).Also the total execution time,with a successful change of factors,was reduced to less than two and a half hour.Conclusions:Multiplex PCR method with shortened operation time was used for the simultaneous detection of total coliforms and Escherichia coli in distribution system of Arak city.It's recommended to be used at least as an initial screening test,and then the positive samples could be randomly tested by MPN.展开更多
Objective:To develop a new technique for diagnosis of Plasmodium knowlesi and at the same time to be able to discriminate among the diverse species of Plasmodium causing human malaria.Methods:In this study the nested ...Objective:To develop a new technique for diagnosis of Plasmodium knowlesi and at the same time to be able to discriminate among the diverse species of Plasmodium causing human malaria.Methods:In this study the nested multiplex malaria PCR was redesigned,targeting the 18S rR NA gene,to identify the fifth human Plasmodium species,Plasmodium knowlesi,together with the other human Plasmodium(Plasmodium falciparum,Plasmodium vivax,Plasmodium ovale and Plasmodium malariae)by amplified fragment size using only two amplification processes and including an internal reaction control to avoid false negatives.Results:The technique was validated with 91 clinical samples obtained from patients with malaria compatible symptoms.The technique showed high sensitivity(100%)and specificity(96%)when it was compared to the reference method employed for malaria diagnosis in the Instituto de Salud Carlos栿and a published real-time PCR malaria assay.Conclusions:The technique designed is an economical,sensitive and specific alternative to current diagnosis methods.Furthermore,the method might be tested in knowlesi-malaria endemic areas with a higher number of samples to confirm the quality of the method.展开更多
Venereal diseases are considered to be the most prevalent infectious diseases in the worldwide. China is now faced with a year-by-year increasing incidence of sexually transmitted diseases (STD), which are spreading...Venereal diseases are considered to be the most prevalent infectious diseases in the worldwide. China is now faced with a year-by-year increasing incidence of sexually transmitted diseases (STD), which are spreading from high-risk groups to the general population. Neisseria gonorrhoeae, Chlamydia trachomatis, Ureaplasma urealyticum and herpes simplex virus-2 (HSV-2) are always regarded as the most common venereal pathogens. The "golden standard" for testing Neisseria gonorrhoeae remains to be bacteria culture or microscopic examination.展开更多
Recently, the incidence of<span> </span><i><span>Candida</span></i><span> infections has substantially increased. Conventional identification methods for </span><...Recently, the incidence of<span> </span><i><span>Candida</span></i><span> infections has substantially increased. Conventional identification methods for </span><i><span>Candida</span></i><span> species are technically difficult to conduct and cannot accurately distinguish each species. The purpose of the present study was to design primers to identify and detect simultaneously</span><span> </span><span>eight medically important </span><i><span>Candida</span></i><span> species using one-step multiplex PCR. PCR primers were designed based on partial sequences of intergenic spacer (IGS) and internal transcribed spacer (ITS) genes of eight medically important </span><i><span>Candida</span></i><span> species. These primers were able to distinguish each </span><i><span>Candida</span></i><span> species and did not display cross-reactivity with representative </span><i><span>Candida </span></i><span>species other than the eight</span><i><span> Candida</span></i><span> species. Moreover, our developed one-step multiplex PCR method is accurate, specific, cost-effective, time-saving, and worked without requiring DNA extraction.</span>展开更多
[Objective]This study aimed to establish a multiplex PCR detection method of herbicide-tolerant canola.[Method] An endogenous reference gene(CruA) and three exogenous genes(T-CaMV 35 S, P-CaMV 35 S and pat) were selec...[Objective]This study aimed to establish a multiplex PCR detection method of herbicide-tolerant canola.[Method] An endogenous reference gene(CruA) and three exogenous genes(T-CaMV 35 S, P-CaMV 35 S and pat) were selected for multiplex PCR. Specific primers were designed based on national standards or related literature. The annealing temperature, ratio of primer concentration and sensitivity of the established multiplex PCR system were optimized. The optimal multiplex PCR system was verified with known samples. [Result] The experimental results showed that the optimal annealing temperature of multiplex PCR was 58 ℃; the optimal ratio of primer concentration(μmol/L) was T-CaMV 35S: CruA: P-CaMV 35S: pat=0.1: 0.2: 0.2: 0.2;the detection sensitivity of the established multiplex PCR method was 0.3 ng. The amplified bands of known samples were completely consistent with the molecular characteristics. [Conclusion] This study provided a rapid, accurate and effective multiplex PCR technique for detection of herbicide-tolerant canola.展开更多
We developed and evaluated a multiplex PCR (m-PCR) for application in routine diagnostic laboratories to detect Campylobacter spp. in stool samples including C. concisus, C. jejuni, and C. coli. When this m-PCR was ap...We developed and evaluated a multiplex PCR (m-PCR) for application in routine diagnostic laboratories to detect Campylobacter spp. in stool samples including C. concisus, C. jejuni, and C. coli. When this m-PCR was applied on spiked faecal samples, C. concisus, C. jejuni, and C. coli were specifically identified at 105 cells/gm of faeces. To compare the sensitivity of the m-PCR with conventional culture techniques, the same spiked stool samples were cultured on an antibiotic free Columbia blood agar using the filtration technique. The detection limit of conventional culture method was 105 cells/gm of stool for C. concisus and 106 cells/gm of stool for C. jejuni and C. coli. The m-PCR was applied to test 127 faecal samples from children with gastroenteritis and the results were compared with the conventional bacterial cultures data. By this m-PCR technique, C. jejuni was detected in 7 samples, C. coli in 2 samples, and C. concisus in 7 samples. However, the conventional culture results for these samples were 6 for C. jejuni, 2 for C. coli and only one sample was positive for C. concisus. In total, 19 samples were positive for Campylobacter spp. by m-PCR while only 9 samples were positive for Campylobacter spp. by culture. In conclusion, m-PCR is more sensitive than the culture technique to detect C. concisus and other fastidious campylobacters in faeces.展开更多
A multiplex reverse transcriptase-polymerase chain reaction(multiplex RT-PCR) assay was developed and subsequently evaluated for its efficacy in the detection of multiple viral infections simultaneously,in swine.Speci...A multiplex reverse transcriptase-polymerase chain reaction(multiplex RT-PCR) assay was developed and subsequently evaluated for its efficacy in the detection of multiple viral infections simultaneously,in swine.Specific primers for each of the 3 RNA viruses,North American genotype porcine reproductive and respiratory syndrome virus,Japanese encephalitis virus,and swine influenza virus,were used in the testing procedure.The assay was shown to be highly sensitive because it could detect as little as 10-5 ng of each of the respective amplicons in a single sample containing a composite of all 3 viruses.The assay was also effective in detecting one or more of the same viruses in various combinations in specimens,including lymph nodes,lungs,spleens,and tonsils,collected from clinically ill pigs and in spleen specimens collected from aborted pig fetuses.The results from the multiplex RT-PCR were confirmed by virus isolation.The relative efficiency(compared to the efficiency of separate assays for each virus) and apparent sensitivity of the multiplex RT-PCR method show that this method has potential for application in routine molecular diagnostic procedures.展开更多
Objective To identify waterborne enteric viruses in Korean surface water. Methods Integrated cell culture(ICC)multiplex reverse transcription-polymerase chain reaction (RT-PCR) was simultaneously designed to detec...Objective To identify waterborne enteric viruses in Korean surface water. Methods Integrated cell culture(ICC)multiplex reverse transcription-polymerase chain reaction (RT-PCR) was simultaneously designed to detect coxsackieviruses (CV), polioviruses (PV), and reoviruses (RV). ICC-multiplex RT-PCR and phylogenetic analysis were conducted using 21 total culturable virus assay (TCVA)-positive sample-inoculated cell cultures. Results CV and RV were detected in 9 samples each, and 3 samples were positive for both CV and RV. PV was not detected in any sample. Molecular phylogenetic analysis of the VP1 gene sequences revealed that CV types B2 and B4 predominated in Korean surface water, and the nucleotide sequences of CV type B2 were clustered with those of CVs isolated from China and Japan. The results suggested that the evolution of these viruses occurred in a region-specific manner. Conclusion CV and RV are detectable in Korean surface water, with a predominance of CV type B2, and the evolution of CV type B2 occur in a region-specific manner.展开更多
基金funded by the National Key R&D Program of China[2021YFC2301102]National Natural Science Foundation of China[82202593]Key R&D Program of Hebei Province[223777100D].
文摘Objective Recombinase-aided polymerase chain reaction(RAP)is a sensitive,single-tube,two-stage nucleic acid amplification method.This study aimed to develop an assay that can be used for the early diagnosis of three types of bacteremia caused by Staphylococcus aureus(SA),Pseudomonas aeruginosa(PA),and Acinetobacter baumannii(AB)in the bloodstream based on recombinant human mannanbinding lectin protein(M1 protein)-conjugated magnetic bead(M1 bead)enrichment of pathogens combined with RAP.Methods Recombinant plasmids were used to evaluate the assay sensitivity.Common blood influenza bacteria were used for the specific detection.Simulated and clinical plasma samples were enriched with M1 beads and then subjected to multiple recombinase-aided PCR(M-RAP)and quantitative PCR(qPCR)assays.Kappa analysis was used to evaluate the consistency between the two assays.Results The M-RAP method had sensitivity rates of 1,10,and 1 copies/μL for the detection of SA,PA,and AB plasmids,respectively,without cross-reaction to other bacterial species.The M-RAP assay obtained results for<10 CFU/mL pathogens in the blood within 4 h,with higher sensitivity than qPCR.M-RAP and qPCR for SA,PA,and AB yielded Kappa values of 0.839,0.815,and 0.856,respectively(P<0.05).Conclusion An M-RAP assay for SA,PA,and AB in blood samples utilizing M1 bead enrichment has been developed and can be potentially used for the early detection of bacteremia.
基金Supported by Agricultural Science and Technology Independent Innovation Fund of Jiangsu Province[CX(12)1003]Science and Technology Support Program of Jiangsu Province(BE2013301)Special Fund for the Construction of Modern Agriculture Industry System of China(CARS-01-47)~~
文摘Rice blast is one of the important diseases in major rice producing areas of China. The main blast resistance genes Pi-ta and Pi-b showed broad-spectrum and durable resistance to rice blast in many rice growing areas of China, which have been widely utilized in rice breeding and commercial production. In this study, on the basis of detection and verification of the genotypes of 22 rice varieties har- boring known blast resistance genes (Pi-ta and Pi-b) and blast susceptibility genes (pi-ta and pi-b), two multiple PCR systems for these genes were established by us- ing the functional markers of blast resistance genes Pi-ta and Pi-b as well as blast susceptibility genes pi-ta and pi-b, respectively. Specifically, multiple PCR system I could simultaneously detect blast resistance genes Pi-ta and Pi-b, while system II could detect simultaneously blast susceptibility genes pi-ta and pi-b. In addition, the genotypes of 336 high generation breeding materials were detected with these two multiple PCR systems. The results were highly consistent with those of conventional single mark detection, indicating that these two multiplex PCR systems were stable, reliable and time-saving. The established multiplex PCR systems may serve as a rapid and efficient method to identify and screen rice germplasm resources and can be applied in marker-assisted selection to polymerize multiple genes for blast resis- tance in rice breeding.
文摘Objectives: To compare multiplex fluorescent PCRwith serum type-specific antibody detection in thediagnosis of herpes simplex virus (HSV) infection andto evaluate its significance in the diagnosis of genitalherpes.Methods: We detected HSV infection in 121 speci-mens collected from patients with genital herpesusing both multiplex fluorescent PCR and serum type-specific antibody detection. HSV viral isolation wasused as the standard control.Results: When compared with the viral isolation, thesensitivity and specificity for multiplex fluorescentPCR were 100% and 88.89%, respectively afterdiscrepant analysis. The sensitivity and specificity fortype-specific antibody detection was 77.68 % and77.78 %, respectively. However, the type-specificantibody detected HSV in two asymptomatic patientswhile the multiplex fluorescent PCR couldn’t detectany HSV DNA from those specimens.Conclusions: Multiplex fluorescent PCR is a verysensitive and specific method for detection and typingof HSV in the lesion of genital herpes, it failed todetect HSV DNA from the asymptomatic patients.Serum type-specific antibody detection was a lesssensitive and specific test but could detect the specificantibody from some asymptomatic patients. Thecombination of these two techniques would allow rapid,sensitive and accurate detection and typing of HSVand help clinical diagnosis and epidemiologic survey-ing of genital herpes.
基金Shenzhen Guangming District Soft Science Research Project,No.2021R01097。
文摘BACKGROUND Influenza A and B virus detection is pivotal in epidemiological surveillance and disease management.Rapid and accurate diagnostic techniques are crucial for timely clinical intervention and outbreak prevention.Quantum dot-encoded microspheres have been widely used in immunodetection.The integration of quantum dot-encoded microspheres with flow cytometry is a well-established technique that enables rapid analysis.Thus,establishing a multiplex detection method for influenza A and B virus antigens based on flow cytometry quantum dot microspheres will help in disease diagnosis.AIM To establish a codetection method of influenza A and B virus antigens based on flow cytometry quantum dot-encoded microsphere technology,which forms the foundation for the assays of multiple respiratory virus biomarkers.METHODS Different quantum dot-encoded microspheres were used to couple the monoclonal antibodies against influenza A and B.The known influenza A and B antigens were detected both separately and simultaneously on a flow cytometer,and the detection conditions were optimized to establish the influenza A and B antigen codetection method,which was utilized for their detection in clinical samples.The results were compared with the fluorescence quantitative polymerase chain reaction(PCR)method to validate the clinical performance of this method.RESULTS The limits of detection of this method were 26.1 and 10.7 pg/mL for influenza A and B antigens,respectively,which both ranged from 15.6 to 250000 pg/mL.In the clinical sample evaluation,the proposed method well correlated with the fluorescent quantitative PCR method,with positive,negative,and overall compliance rates of 57.4%,100%,and 71.6%,respectively.CONCLUSION A multiplex assay for quantitative detection of influenza A and B virus antigens has been established,which is characterized by high sensitivity,good specificity,and a wide detection range and is promising for clinical applications.
基金National Basic Research Program of China (No. 2001CB109001)National High-Tech Research Program of China (No. 2002AA212041)
文摘Objective To develop a technique for simultaneous detection of various target genes in Roundup Ready soybean by combining multiplex PCR and low-density DNA microarray. Methods Two sets of the multiplex PCR system were used to amplify the target genes in genetically modified (GM) soybean. Seventeen capture probes (PCR products) and 17 pairs of corresponding primers were designed according to the genetic characteristics of Rroundup Ready soybean (GTS40-3-2), maize (MonS10, Nk603, GA21), canola (T45, MS1/RF1), and rice (SCK) in many identified GM crops. All of the probes were categorized and identified as species-specific probes. One negative probe and one positive control probe were used to assess the efficiency of all reactions, and therefore eliminate any false positive and negative results. After multiplex PCR reaction, amplicons were adulterated with Cy5-dUTP and hybridized with DNA microarray. The array was then scanned to display the specific hybridization signals of target genes. The assay was applied to the analysis of sample of certified transgenic soybean (Roundup Ready GTS40-3-2) and canola (MS1/RF1). Results A combination technique of multiplex PCR and DNA microarray was successfully developed to identify multi-target genes in Roundup Ready soybean and MS 1/RF1 canola with a great specificity and reliability. Reliable identification of genetic characteristics of Roundup Ready of GM soybean from genetically modified crops was achieved at 0.5% transgenic events, indicating a high sensitivity. Conclusion A combination technique of multiplex PCR and low-density DNA microarray can reliably detect and identify the genetically modified crops.
基金supported by grants from the Priority Project on Infectious Disease Control and Prevention(2012ZX10004215,2013ZX10004610)from Ministry of Health,China,and the Science Foundation for the State Key Laboratory for Infectious Disease Prevention and Control from China(Grant No.2015SKLID508)the National Natural Science Foundation of China(Grant No.81671985)and(Grant No.81170009)
文摘Objective Lower respiratory tract infections continue to pose a significant threat to human health. It is important to accurately and rapidly detect respiratory bacteria. To compensate for the limits of current respiratory bacteria detection methods, we developed a combination of multiplex polymerase chain reaction (PCR) and capillary electrophoresis (MPCE) assay to detect thirteen bacterial pathogens responsible for lower respiratory tract infections, including Streptococcus pneumoniae, Haemophilus influenzae, Moraxella catorrholis, Pseudomonas aeruginosa, Klebsiella pneumoniae, Escherichia coli, Staphylococcus aureus, Mycoplasma pneumoniae, Legionella spp., Bordetella pertussis, Mycobacterium tuberculosis complex, Corynebactefium diphthefiae, and Streptococcus pyogenes. Methods Three multiplex PCR reactions were built, and the products were analyzed by capillary electrophoresis using the high-throughput DNA analyzer. The specificity of the MPCE assay was examined and the detection limit was evaluated using DNA samples from each bacterial strain and the simulative samples of each strain. This assay was further evaluated using 152 clinical specimens and compared with real-time PCR reactions. For this assay, three nested-multiplex-PCRs were used to detect these clinical specimens. Results The detection limits of the MPCE assay for the 13 pathogens were very low and ranged from 10-7 to 10-2 ng/μL. Furthermore, analysis of the 252 clinical specimens yielded a specificity ranging from 96.5%-100.0%, and a sensitivity of 100.0% for the 13 pathogens. Conclusion This study revealed that the MPCE with high specificity and sensitivity. This assay survey of respiratory pathogens. assay is a rapid, reliable, and high-throughput method has great potential in the molecular epidemiological.
文摘Objective To establish multiplex PCR-based assays for detecting H.influenzae and H.parainfluenzae. And the PCR-based assays were applied to detect the carriage rates of H.influenzae and H.parainfluenzae in nasopharyngeal swab specimens which were collected from healthy children. Methods Multiplex primers for species-specific PCR were designed by using DNAstar soft based on the sequences of 165 rRNA genes from genus Haemophilus to detect H.influenzae and H.parainfluenzae. Results The sensitivity of the 165 rRNA PCR assay for detecting H.influenzae and H.parainfluenzae was 97.53% and 100% respectively, and the specificity was 95.89% and 96.63% respectively. Youden's Index on the ability to detect H.influenzae and H.parainfluenzae was 0.9342 and 0.9663 respectively. 666 nasopharyngeal swab specimens were collected from healthy children. The detection rates of H.influenzae and H.parainfluenzae were 14.11% and 16.07% respectively by using isolation and culture methods. The detection rates of H.influenzae and H.parainfluenzae were 43.54% and 57.96% respectively by 165 rRNA PCR assays. The carriage rates of serotypes a, b, c, d, e, f and non-typeable isolates were 0% (0/666), 0.15% (1/666), 1.20% (8/666), 0.15% (1/666), 1.20% (8/666), 1.80% (12/666), 95.50% (636/666) respectively. Conclusion The multiplex PCR assays were very rapid, reliable and feasible methods for detection of H.influenzae and H.parainfluenzae in pharyngeal swab specimens which were compared to conventional isolation and culture methods. 95.5% of H.influenzae strains in healthy children were nontypeable. The encapsulated or typable strains were mainly three serotypes which was c, e, and f serotype.
文摘PCRs based on different genes of Actinobacillus pleuropneumoniae have been developed for detecting and identifying A. pleuropneumoniae. Some of them could amplify positive fragments from the phylogenetically closely related species bacteria. To improve veracity and specificity of PCR, a species-specific multiplex PCR assay was developed to identify and detect A. pleuropneumoniae, based on the 3'-terminus of the species-specific apxlVA gene and the already existing species-specific primers in the omlA gene. Both 346-bp and 950-bp fragments could be simultaneously amplified from all A. pleuropneumoniae reference strains and isolates, and the species specificity of the assay was evaluated with a collection of ten strains representing eight different species bacteria including species normally found in the respiratory tracts of swine. All of these strains turned out negative in the multiplex PCR. All sequences of products of multiplex PCR randomly sampled were also correct. The sensitivity of the multiplex PCR was determined to be 10 pg of A. pleuropneumoniae DNA. The multiplex PCR and bacterial isolation were compared to determine their sensitivities by using experimentally infected pigs and clinical disease pigs. The multiplex PCR was more sensitive than bacterial isolation. The multiplex PCR was also evaluated on mixed bacterial cultures from clinical healthy pigs. 26/100 (26%) of the subclinically infected pigs were detected from clinical healthy pigs. The results indicate that the multiplex PCR assay is a sensitive, highly specific, and effective diagnostic tool for identification and detection of A. pleuropneumoniae.
文摘Objective:To study virulence and regulatory genes(hlyA,ctxB,tcpI) in clinical strains of Vibrio ckolerae(V.cholerae),simultaneously.Methods:Three important genes,tepI,hlyA and ctxB were used for detection of toxigenic and pathogenic V.cholera by chain reaction assay method. Results:According to the results of the PCR,the incidence of hlyA,tcpI,and ctxB genes in clinical isolates was obtained as 94.7%(72 sample),90.8%(69 sample),and 92.1%(70 sample), respectively.Five strains possessed all genes except ctxB,six strains possessed all genes except tcpI,four strains possessed all genes except hlyA,one strain possessed only hlyA and 60 strains contained a combination of three genes.Including hlyA,ctxB and tcpI,Conclusions:Result show that this method could be reliable to detect toxigenic-pathogenic strains of V.cholerae in Iran.
基金supported by the China Mega Project for Infectious Disease(2013ZX10004-001,2012ZX10004-215,2013ZX10004-202,and 2013ZX10004804-007)
文摘Objective This study is aimed to develop a two-tube melting curve-based multiplex real time PCR assay (MCMRT-PCR) for the simultaneous detection of six common foodborne pathogenic bacteria (diarrhoeagenic Escherichia coli, Salmonella, and 5higella in tube 1, Staphylococcus aureus, Vibrio parahaemolyticus, and Listeria monocytogenes in tube 2). Methods A two-tube MCMRT-PCR assay was performed on 7900HT Fast Real-Time PCR System {Applied Biosystems, USA). Amplification by PCR was optimized to obtain high efficiency. The sensitivity and specificity of assays were investigated. Results The detection limit of optimized MCMRT-PCR assay was 3.9x102 CFU/mLfor S. aureus, 4.4x102 CFU/mL for L. monocytogenes, 3.0x102 CFU/mL for Salmonella, 2.5x102 CFU/mL for Shigella, 2.1x102 CFU/mL for V. parahaemolyticus, and 1.2x102 CFU/mL for E. coll. The feasibility of MCMRT-PCR was further evaluated using artificially contaminated milk, the sensitivity was at the level of 10s CFU/mL. Conclusion A two-tube MCMRT-PCR assay using six primer sets was developed for detection of multiple pathogens. Our findings demonstrates that the proposed two-tube assay is reliable, useful and rapid for simultaneous detection of six foodborne pathogenic bacteria with an intended application in provincial Centers for Diseases Control and Prevention (CDC).
文摘Objective:To evaluate microscopy,OptiMAL<sup>?</sup> and multiplex PCR for the identification of Plasmodium falciparum(P.falciparum) and Plasmodium vivax(P.vivax) from the field isolates of Bikaner,Rajasthan(Northwest India).Methods:In this study,a multiplex PCR(P.falciparum and P.vivax) was further developed with the incorporation of Plasmodium malariae(P.malariae) specific primer and also a positive control.The performance of microscopy,plasmodium lactate dehydrogenase(pLDH) based malaria rapid diagnostic test OptiMAL<sup>?</sup> and 18S rRNA gene based multiplex PCR for the diagnosis of P.falciparum and P.vivax was compared.Results:The three species multiplex PCR if.falciparum,P.vivax and P.malariae) with an inbuilt positive control was developed and evaluated.In comparison with multiplex PCR,which showed the sensitivity and specificity of 99.36%(95%CI,98.11%-100.00%) and 100.00%(95%CI,100.00%-100.00%),the sensitivity and specificity of microscopy was 90.44%(95%CI,88.849-95.04%) and 99.22%(95% CI,97.71%-100.00%),and OptiMAL<sup>?</sup> was 93.58%(95%CI,89.75%-97.42%) and 97.69%(95%CI, 95.10%-100.00%).The efficiencies were 99.65%,95.10%and 95.45%for multiplex PCK.microscopy and OptiMAL<sup>?</sup>.respectively.Conclusions:Our results raise concerns over the overall sensitivities of microscopy and OptiMAL<sup>?</sup>,when compared to the multiplex PCR and thus stress the need for new molecular interventions in the accurate detection of the malarial parasites.This further highlights the fact that further developments are needed to improve the performance of rapid diagnostic tests at field level.
基金the funding support provided by the Department of Biotechnology(DBT),Government of India(Grant Nos.BT/AB/FG-2 (PH-II)/2009 and BT/PR11705/AGR/02/646/2008)
文摘In marker-assisted breeding for bacterial blight(BB) resistance in rice, three major resistance genes, viz., Xa21, xa13 and xa5, are routinely deployed either singly or in combinations. As efficient and functional markers are yet to be developed for xa13 and xa5, we have developed simple PCR-based functional markers for both the genes. For xa13, we designed a functional PCR-based marker, xa13-prom targeting the In Del polymorphism in the promoter of candidate gene Os8N3 located on chromosome 8 of rice. With respect to xa5, a multiplex-PCR based functional marker system, named xa5 FM, consisting of two sets of primer pairs targeting the 2-bp functional nucleotide polymorphism in the exon II of the gene TFIIA5(candidate for xa5), has been developed. Both xa13-prom and xa5 FM can differentiate the resistant and susceptible alleles for xa13 and xa5, respectively, in a co-dominant fashion. Using these two functional markers along with the already reported functional PCR-based marker for Xa21(p TA248), we designed a single-tube multiplex PCR based assay for simultaneous detection of all the three major resistance genes and demonstrated the utility of the multiplex marker system in a segregating population.
基金Supported by the Ministry of Power of I.R.Iran(Grant No.201)
文摘Objective:To analyse molecular detection of coliforms and shorten the time of PCR.Methods:Rapid detection of coliforms by amplification of lacZ and uidA genes in a multiplex PCR reaction was designed and performed in comparison with most probably number(MPN)method for 16 artificial and 101 field samples.The molecular method was also conducted on isolated coliforms from positive MPN samples;standard sample for verification of microbial method certificated reference material;isolated strains from certificated reference material and standard bacteria.The PCR and electrophoresis parameters were changed for reducing the operation time.Results:Results of PCR for lacZ and uidA genes were similar in all of standard,operational and artificial samples and showed the 876 bp and 147 bp bands of lacZ and uidA genes by multiplex PCR.PCR results were confirmed by MPN culture method by sensitivity 86%(95%CI:0.71-0.93).Also the total execution time,with a successful change of factors,was reduced to less than two and a half hour.Conclusions:Multiplex PCR method with shortened operation time was used for the simultaneous detection of total coliforms and Escherichia coli in distribution system of Arak city.It's recommended to be used at least as an initial screening test,and then the positive samples could be randomly tested by MPN.
基金supported by AESI-ISC Ⅲ grant number PI14C Ⅲ/00014
文摘Objective:To develop a new technique for diagnosis of Plasmodium knowlesi and at the same time to be able to discriminate among the diverse species of Plasmodium causing human malaria.Methods:In this study the nested multiplex malaria PCR was redesigned,targeting the 18S rR NA gene,to identify the fifth human Plasmodium species,Plasmodium knowlesi,together with the other human Plasmodium(Plasmodium falciparum,Plasmodium vivax,Plasmodium ovale and Plasmodium malariae)by amplified fragment size using only two amplification processes and including an internal reaction control to avoid false negatives.Results:The technique was validated with 91 clinical samples obtained from patients with malaria compatible symptoms.The technique showed high sensitivity(100%)and specificity(96%)when it was compared to the reference method employed for malaria diagnosis in the Instituto de Salud Carlos栿and a published real-time PCR malaria assay.Conclusions:The technique designed is an economical,sensitive and specific alternative to current diagnosis methods.Furthermore,the method might be tested in knowlesi-malaria endemic areas with a higher number of samples to confirm the quality of the method.
基金supported by Zhejiang Provincial Population and Family Planning Foundation of China (N20100011)
文摘Venereal diseases are considered to be the most prevalent infectious diseases in the worldwide. China is now faced with a year-by-year increasing incidence of sexually transmitted diseases (STD), which are spreading from high-risk groups to the general population. Neisseria gonorrhoeae, Chlamydia trachomatis, Ureaplasma urealyticum and herpes simplex virus-2 (HSV-2) are always regarded as the most common venereal pathogens. The "golden standard" for testing Neisseria gonorrhoeae remains to be bacteria culture or microscopic examination.
文摘Recently, the incidence of<span> </span><i><span>Candida</span></i><span> infections has substantially increased. Conventional identification methods for </span><i><span>Candida</span></i><span> species are technically difficult to conduct and cannot accurately distinguish each species. The purpose of the present study was to design primers to identify and detect simultaneously</span><span> </span><span>eight medically important </span><i><span>Candida</span></i><span> species using one-step multiplex PCR. PCR primers were designed based on partial sequences of intergenic spacer (IGS) and internal transcribed spacer (ITS) genes of eight medically important </span><i><span>Candida</span></i><span> species. These primers were able to distinguish each </span><i><span>Candida</span></i><span> species and did not display cross-reactivity with representative </span><i><span>Candida </span></i><span>species other than the eight</span><i><span> Candida</span></i><span> species. Moreover, our developed one-step multiplex PCR method is accurate, specific, cost-effective, time-saving, and worked without requiring DNA extraction.</span>
基金Supported by Special Fund for Modern Agricultural Technology Innovation and Demonstration of Sichuan Province(2014CXSF-040)General Natural Science Project of the Education Department of Sichuan Province(15ZB0331)
文摘[Objective]This study aimed to establish a multiplex PCR detection method of herbicide-tolerant canola.[Method] An endogenous reference gene(CruA) and three exogenous genes(T-CaMV 35 S, P-CaMV 35 S and pat) were selected for multiplex PCR. Specific primers were designed based on national standards or related literature. The annealing temperature, ratio of primer concentration and sensitivity of the established multiplex PCR system were optimized. The optimal multiplex PCR system was verified with known samples. [Result] The experimental results showed that the optimal annealing temperature of multiplex PCR was 58 ℃; the optimal ratio of primer concentration(μmol/L) was T-CaMV 35S: CruA: P-CaMV 35S: pat=0.1: 0.2: 0.2: 0.2;the detection sensitivity of the established multiplex PCR method was 0.3 ng. The amplified bands of known samples were completely consistent with the molecular characteristics. [Conclusion] This study provided a rapid, accurate and effective multiplex PCR technique for detection of herbicide-tolerant canola.
文摘We developed and evaluated a multiplex PCR (m-PCR) for application in routine diagnostic laboratories to detect Campylobacter spp. in stool samples including C. concisus, C. jejuni, and C. coli. When this m-PCR was applied on spiked faecal samples, C. concisus, C. jejuni, and C. coli were specifically identified at 105 cells/gm of faeces. To compare the sensitivity of the m-PCR with conventional culture techniques, the same spiked stool samples were cultured on an antibiotic free Columbia blood agar using the filtration technique. The detection limit of conventional culture method was 105 cells/gm of stool for C. concisus and 106 cells/gm of stool for C. jejuni and C. coli. The m-PCR was applied to test 127 faecal samples from children with gastroenteritis and the results were compared with the conventional bacterial cultures data. By this m-PCR technique, C. jejuni was detected in 7 samples, C. coli in 2 samples, and C. concisus in 7 samples. However, the conventional culture results for these samples were 6 for C. jejuni, 2 for C. coli and only one sample was positive for C. concisus. In total, 19 samples were positive for Campylobacter spp. by m-PCR while only 9 samples were positive for Campylobacter spp. by culture. In conclusion, m-PCR is more sensitive than the culture technique to detect C. concisus and other fastidious campylobacters in faeces.
基金supported by a grant from the Out-standing Person Innovation Foundation of Henan,China(0621002100)
文摘A multiplex reverse transcriptase-polymerase chain reaction(multiplex RT-PCR) assay was developed and subsequently evaluated for its efficacy in the detection of multiple viral infections simultaneously,in swine.Specific primers for each of the 3 RNA viruses,North American genotype porcine reproductive and respiratory syndrome virus,Japanese encephalitis virus,and swine influenza virus,were used in the testing procedure.The assay was shown to be highly sensitive because it could detect as little as 10-5 ng of each of the respective amplicons in a single sample containing a composite of all 3 viruses.The assay was also effective in detecting one or more of the same viruses in various combinations in specimens,including lymph nodes,lungs,spleens,and tonsils,collected from clinically ill pigs and in spleen specimens collected from aborted pig fetuses.The results from the multiplex RT-PCR were confirmed by virus isolation.The relative efficiency(compared to the efficiency of separate assays for each virus) and apparent sensitivity of the multiplex RT-PCR method show that this method has potential for application in routine molecular diagnostic procedures.
文摘Objective To identify waterborne enteric viruses in Korean surface water. Methods Integrated cell culture(ICC)multiplex reverse transcription-polymerase chain reaction (RT-PCR) was simultaneously designed to detect coxsackieviruses (CV), polioviruses (PV), and reoviruses (RV). ICC-multiplex RT-PCR and phylogenetic analysis were conducted using 21 total culturable virus assay (TCVA)-positive sample-inoculated cell cultures. Results CV and RV were detected in 9 samples each, and 3 samples were positive for both CV and RV. PV was not detected in any sample. Molecular phylogenetic analysis of the VP1 gene sequences revealed that CV types B2 and B4 predominated in Korean surface water, and the nucleotide sequences of CV type B2 were clustered with those of CVs isolated from China and Japan. The results suggested that the evolution of these viruses occurred in a region-specific manner. Conclusion CV and RV are detectable in Korean surface water, with a predominance of CV type B2, and the evolution of CV type B2 occur in a region-specific manner.