Based on the internet technology,it has become possible to complete remote monitoring and fault diagnosis for the numerical control machine.In order to capture the micro-shock signal induced by the incipient fault on ...Based on the internet technology,it has become possible to complete remote monitoring and fault diagnosis for the numerical control machine.In order to capture the micro-shock signal induced by the incipient fault on the rotating parts,the reso- nance demodulation technology is utilized in the system.As a subsystem of the remote monitoring system,the embedded data acquisi- tion instrument not only integrates the demodulation board but also complete the collection and preprocess of monitoring data from different machines.Furthermore,through connecting to the internet,the data can be transferred to the remote diagnosis center and data reading and writing function can be finished in the database.At the same time,the problem of the IP address floating in the dial-up of web server is solved by the dynamic DNS technology.Finally,the remote diagnosis software developed on the Lab VIEW platform can analyze the monitoring data from manufacturing field.The research results have indicated that the equipment status can be monitored by the system effectively.展开更多
This paper presents a multi-interface embedded server architecture for remote real-time monitoring system and distributed monitoring applications. In the scheme,an embedded microprocessor( LPC3250 from NXP) is chosen ...This paper presents a multi-interface embedded server architecture for remote real-time monitoring system and distributed monitoring applications. In the scheme,an embedded microprocessor( LPC3250 from NXP) is chosen as the CPU of the embedded server with a linux operation system( OS) environment. The embedded server provides multiple interfaces for supporting various application scenarios. The whole network is based on local area network and adopts the Browser / Server( B / S) model. The monitoring and control node is as a browser endpoint and the remote node with an embedded server is as a server endpoint. Users can easily acquire various sensors information through writing Internet protocol address of remote node on the computer browser. Compared with client / server( C / S) mode,B / S model needs less maintain and can be applicable to large user group. In addition,a simple network management protocol( SNMP) is used for management of devices in Internet protocol( IP) networks. The results of the demonstration experiment show that the proposed system gives good support to manage the network from different user terminals and allows the users to better interact with the ambient environment.展开更多
After giving a short review of the methods used for detecting and monitoring in general systems, this paper describes the way of communication between computer and Computer Numerical Control (CNC) Machining Center (MC...After giving a short review of the methods used for detecting and monitoring in general systems, this paper describes the way of communication between computer and Computer Numerical Control (CNC) Machining Center (MC). Based on these, the paper addresses the means of performing in cycle measurement for manufacturing quality, provides an approach of improving the state of manufacturing process by achieving the real time change of control parameters according to the level of manufacturing process, and discusses the technique of implementing in process dimensional errors compensation corresponding to the in cycle measurement. The results of the experiments show that the frame design is successful and the operation is reliable. The system is taking shape nowadays.展开更多
For decades, the power system was highly centralized. With the growing integration of distributed generations into the system, there is a necessity for bi-directional communication methods to monitor and control the r...For decades, the power system was highly centralized. With the growing integration of distributed generations into the system, there is a necessity for bi-directional communication methods to monitor and control the remote assets. The primary objective of this paper is to develop a communication link for monitoring and controlling a grid-connected inverter in a remote location. Furthermore, the paper presents developments that have been incorporated to improve the communication link. The literature survey indicates that LoRa is superior compared to other technologies, but has some security and reliability issues. This paper also presents an encryption algorithm to improve the security of the LoRa link. Local data storage added to the system before transmitting data increases the system reliability. A display at the transmission end is added to improve the user-friendliness of the communication link. A Powerline Communication link is parallelly added to the LoRa link to improve the reliability. Finally, tests are conducted with an actual inverter and the results are presented. The tests show that the developed communication link has improved security and reliability, while its open nature makes it highly scalable and adaptable for employment in other smart grid applications.展开更多
A monitoring program was developed to assess the cover of saltgrass managed for dust control on the saline dry Owens Lake. Although the original intent was to manage the vegetation as total cover that included green a...A monitoring program was developed to assess the cover of saltgrass managed for dust control on the saline dry Owens Lake. Although the original intent was to manage the vegetation as total cover that included green and senesced leaf and stem material, aged leaves that make up a large proportion of total cover were not differentiable spectrally from the background salt and lakebed. Hence, greenness-based indices were explored for detection of plant recruitment. Since all plant cover begins as green and growing, greenness indices provide a measure of all future cover whether living or senesced. The criteria for judging compliance were changed so that spatially variable vegetation cover measured as a milestone will need to be met in the future. A derivative of NDVI, NDVIx, calculated using scene statistics, proved highly accurate, to about 0.001 of this index and with an average signal to noise ratio of 64. This high level of accuracy allowed detection of small changes in vegetation growth and vigor. Performance according to the benchmark-as-par standard was determined through combined use of cumulative distribution functions and derivative maps.展开更多
Extensive dust control on the dry Owens Lake mainly uses constructed basins that are flooded with shallow depths of fresh water. This dust control is mandated by law as a minimum percent of the area of each individual...Extensive dust control on the dry Owens Lake mainly uses constructed basins that are flooded with shallow depths of fresh water. This dust control is mandated by law as a minimum percent of the area of each individual wetting basin. Wetted surfaces are evaluated for area and degree of wetness using the shortwave infrared (SWIR) band of Landsat TM, or similar earth observation satellite sensor. The SWIR region appropriate for these measurements lies within the electromagnetic spectrum between about 1.5 and 1.8 μm wavelengths. A threshold value for Landsat TM5 band 5 reflectance of 0.19 was found to conform with surfaces having a threshold for adequate wetting at a nascent point where rapid drying would occur following loss of capillary connection with groundwater. This threshold is robust and requires no atmospheric correction for the effects of aerosol scatter and attenuation as long as the features on the image appear clear. Monthly monitoring of surface wetting has proven accurate, verifiable and repeatable using these methods. This threshold can be calibrated for any Earth observation satellite that records the appropriate SWIR region. The monitoring program is expected to provide major input for the final phase of the dust control program that will have a focus to conserve water and resources.展开更多
In this paper an expert system for remote fault diagnosis in the ship lift was developed by analysis of the fault tree and combination with VPN. The fault tree was constructed based on the operation condition of the s...In this paper an expert system for remote fault diagnosis in the ship lift was developed by analysis of the fault tree and combination with VPN. The fault tree was constructed based on the operation condition of the ship lift. The diagnosis model was constructed by hierarchical classification of the fault tree structure, and the inference mechanism was given. Logical structure of the fault diagnosis in the ship lift was proposed. The implementation of the expert system for remote fault diagnosis in the ship lift was discussed, and the expert system developed was realized on the VPN virtual network. The system was applied to the Gaobaozhou ship lift project, and it ran successfully.展开更多
The development of computer intelligent control of mechanical engineering is a crucial change in the development process of the field of construction machinery production in our country at present, and of course it is...The development of computer intelligent control of mechanical engineering is a crucial change in the development process of the field of construction machinery production in our country at present, and of course it is also an inevitable development trend. For the effective application of intelligent production, it can effectively improve the disadvantages existing in the traditional mechanical production mode, and make certain contribution to the further improvement of mechanical production efficiency. The staff of engineering enterprises need to improve their knowledge of intelligent development, innovate the way of production management, and actively integrate computer intelligent control technology to promote the development of China's mechanical engineering intelligence and social progress.展开更多
There are some disadvantages, such as complicated wiring, high cost, poor monitoring flexibility, low accuracy and high energy consumption in traditional greenhouse environment monitoring system which based on previou...There are some disadvantages, such as complicated wiring, high cost, poor monitoring flexibility, low accuracy and high energy consumption in traditional greenhouse environment monitoring system which based on previous wireless sensor networks (WSN). Aiming at these problems, a greenhouse environmental parameter monitoring system had been designed based on internet of things technology in this paper. A set of control system with good robustness, strong adaptive ability and small overshoot was set up by combining the fuzzy proportion-integral-derivative (PID) control. The system was composed of a number of independent greenhouse monitoring systems. The server could provide remote monitoring access management services after the collected data were transmitted. The data transmission part of greenhouse was based on ZigBee networking protocol. And the data were sent to intelligent system via gateway connected to the internet. Compared to the classical PID control and fuzzy control, the fuzzy PID control could quickly and accurately adjust the corresponding parameters to the set target. The overshoot was also relatively small. The simulation results showed that the amount of overshoot was reduced 20% compared with classical PID control.展开更多
This paper designs a set of ventilation and dust removal in coal mine test device and PLC monitoring system. The ventilation and dust removal test device has a set of ventilation and dust removal functions, can automa...This paper designs a set of ventilation and dust removal in coal mine test device and PLC monitoring system. The ventilation and dust removal test device has a set of ventilation and dust removal functions, can automatically monitor air volume, air pressure, resistance and other performance parameters of ventilator and precipitator. The PLC monitoring system can remotely start and stop the variable frequency speed control on the ventilation machine and dust collector, and it can real-time monitor operation state, such as the running current and the parameters of ventilator and dust collector. The paper simulate and realize computer remote centralized monitoring of underground ventilation for mine ventilation system. The actual application shows that: the system is stable and reliable, simple operation, strong scalability.展开更多
Background A patented remote controlled capsule (RCC) has recently been developed to provide noninvasive drug delivery to selected sites in the human gut that allows assessment of regional gastrointestinal (GI) dr...Background A patented remote controlled capsule (RCC) has recently been developed to provide noninvasive drug delivery to selected sites in the human gut that allows assessment of regional gastrointestinal (GI) drug absorption under a normal physiological environment. The objective of this study was to investigate the rate and extent of aminophylline absorption after site-specific delivery of the drug in the GI tract using RCC and a magnetic marker monitoring (MMM) technique. Methods This study was conducted in twelve healthy male subjects, in a three-treatment, randomized, crossover manner with a 7-day washout. Eligible subjects received a 150 mg aminophylline dose through an oral administration, or via a remote controlled capsule, delivered to the small bowel or ascending colon. MMM was employed to monitor the GI transit of the RCC, and the radio-frequency signal was used to activate capsules at target sites. Blood samples were obtained at regular intervals until 24 hours post dose/activation. Plasma theophylline concentrations were measured by a TDx~ System Analyzer. A comparison of the PK profile with the oral dosing route of aminophylline was performed after delivery to the small bowel and colon. Results The RCC was well tolerated in volunteers. The mean capsule activation time for the small bowel and ascending colon was 2.07 hours and 6.08 hours post dose. Aminophylline had similar absorption profiles from the small bowel compared with the stomach, with an area under the curve (AUCt) ratio of 92% vs. the stomach, but a lower absorption profile from the ascending colon, with an AUCt ratio of 47.2% vs. the stomach. Conclusions The proprietary of the RCC and MMM technique offer the opportunity to obtain data on the intestinal absorption of a drug in humans under noninvasive conditions. Aminophylline is rapidly and efficiently absorbed from the small bowel. While colonic absorption was limited by the poor water condition although effective absorption was observed from the ascending colon. This provides an opportunity for rational development of modified-release formulations as well as alternative dosage forms.展开更多
文摘Based on the internet technology,it has become possible to complete remote monitoring and fault diagnosis for the numerical control machine.In order to capture the micro-shock signal induced by the incipient fault on the rotating parts,the reso- nance demodulation technology is utilized in the system.As a subsystem of the remote monitoring system,the embedded data acquisi- tion instrument not only integrates the demodulation board but also complete the collection and preprocess of monitoring data from different machines.Furthermore,through connecting to the internet,the data can be transferred to the remote diagnosis center and data reading and writing function can be finished in the database.At the same time,the problem of the IP address floating in the dial-up of web server is solved by the dynamic DNS technology.Finally,the remote diagnosis software developed on the Lab VIEW platform can analyze the monitoring data from manufacturing field.The research results have indicated that the equipment status can be monitored by the system effectively.
基金Sponsored by the National High Technology Research and Development Program(Grant No.2012AA02A604)
文摘This paper presents a multi-interface embedded server architecture for remote real-time monitoring system and distributed monitoring applications. In the scheme,an embedded microprocessor( LPC3250 from NXP) is chosen as the CPU of the embedded server with a linux operation system( OS) environment. The embedded server provides multiple interfaces for supporting various application scenarios. The whole network is based on local area network and adopts the Browser / Server( B / S) model. The monitoring and control node is as a browser endpoint and the remote node with an embedded server is as a server endpoint. Users can easily acquire various sensors information through writing Internet protocol address of remote node on the computer browser. Compared with client / server( C / S) mode,B / S model needs less maintain and can be applicable to large user group. In addition,a simple network management protocol( SNMP) is used for management of devices in Internet protocol( IP) networks. The results of the demonstration experiment show that the proposed system gives good support to manage the network from different user terminals and allows the users to better interact with the ambient environment.
文摘After giving a short review of the methods used for detecting and monitoring in general systems, this paper describes the way of communication between computer and Computer Numerical Control (CNC) Machining Center (MC). Based on these, the paper addresses the means of performing in cycle measurement for manufacturing quality, provides an approach of improving the state of manufacturing process by achieving the real time change of control parameters according to the level of manufacturing process, and discusses the technique of implementing in process dimensional errors compensation corresponding to the in cycle measurement. The results of the experiments show that the frame design is successful and the operation is reliable. The system is taking shape nowadays.
文摘For decades, the power system was highly centralized. With the growing integration of distributed generations into the system, there is a necessity for bi-directional communication methods to monitor and control the remote assets. The primary objective of this paper is to develop a communication link for monitoring and controlling a grid-connected inverter in a remote location. Furthermore, the paper presents developments that have been incorporated to improve the communication link. The literature survey indicates that LoRa is superior compared to other technologies, but has some security and reliability issues. This paper also presents an encryption algorithm to improve the security of the LoRa link. Local data storage added to the system before transmitting data increases the system reliability. A display at the transmission end is added to improve the user-friendliness of the communication link. A Powerline Communication link is parallelly added to the LoRa link to improve the reliability. Finally, tests are conducted with an actual inverter and the results are presented. The tests show that the developed communication link has improved security and reliability, while its open nature makes it highly scalable and adaptable for employment in other smart grid applications.
文摘A monitoring program was developed to assess the cover of saltgrass managed for dust control on the saline dry Owens Lake. Although the original intent was to manage the vegetation as total cover that included green and senesced leaf and stem material, aged leaves that make up a large proportion of total cover were not differentiable spectrally from the background salt and lakebed. Hence, greenness-based indices were explored for detection of plant recruitment. Since all plant cover begins as green and growing, greenness indices provide a measure of all future cover whether living or senesced. The criteria for judging compliance were changed so that spatially variable vegetation cover measured as a milestone will need to be met in the future. A derivative of NDVI, NDVIx, calculated using scene statistics, proved highly accurate, to about 0.001 of this index and with an average signal to noise ratio of 64. This high level of accuracy allowed detection of small changes in vegetation growth and vigor. Performance according to the benchmark-as-par standard was determined through combined use of cumulative distribution functions and derivative maps.
文摘Extensive dust control on the dry Owens Lake mainly uses constructed basins that are flooded with shallow depths of fresh water. This dust control is mandated by law as a minimum percent of the area of each individual wetting basin. Wetted surfaces are evaluated for area and degree of wetness using the shortwave infrared (SWIR) band of Landsat TM, or similar earth observation satellite sensor. The SWIR region appropriate for these measurements lies within the electromagnetic spectrum between about 1.5 and 1.8 μm wavelengths. A threshold value for Landsat TM5 band 5 reflectance of 0.19 was found to conform with surfaces having a threshold for adequate wetting at a nascent point where rapid drying would occur following loss of capillary connection with groundwater. This threshold is robust and requires no atmospheric correction for the effects of aerosol scatter and attenuation as long as the features on the image appear clear. Monthly monitoring of surface wetting has proven accurate, verifiable and repeatable using these methods. This threshold can be calibrated for any Earth observation satellite that records the appropriate SWIR region. The monitoring program is expected to provide major input for the final phase of the dust control program that will have a focus to conserve water and resources.
文摘In this paper an expert system for remote fault diagnosis in the ship lift was developed by analysis of the fault tree and combination with VPN. The fault tree was constructed based on the operation condition of the ship lift. The diagnosis model was constructed by hierarchical classification of the fault tree structure, and the inference mechanism was given. Logical structure of the fault diagnosis in the ship lift was proposed. The implementation of the expert system for remote fault diagnosis in the ship lift was discussed, and the expert system developed was realized on the VPN virtual network. The system was applied to the Gaobaozhou ship lift project, and it ran successfully.
文摘The development of computer intelligent control of mechanical engineering is a crucial change in the development process of the field of construction machinery production in our country at present, and of course it is also an inevitable development trend. For the effective application of intelligent production, it can effectively improve the disadvantages existing in the traditional mechanical production mode, and make certain contribution to the further improvement of mechanical production efficiency. The staff of engineering enterprises need to improve their knowledge of intelligent development, innovate the way of production management, and actively integrate computer intelligent control technology to promote the development of China's mechanical engineering intelligence and social progress.
基金Supported by the 13th Five-year National Key R&D Program:Development and Verification of Information Perception and Environment Intelligent Control System for Dairy Cattle and Beef Cattle(2016YFD0700204-02)Quality and Brand Construction of "Internet+County Characteristic Agricultural Products"(ZY17C06)
文摘There are some disadvantages, such as complicated wiring, high cost, poor monitoring flexibility, low accuracy and high energy consumption in traditional greenhouse environment monitoring system which based on previous wireless sensor networks (WSN). Aiming at these problems, a greenhouse environmental parameter monitoring system had been designed based on internet of things technology in this paper. A set of control system with good robustness, strong adaptive ability and small overshoot was set up by combining the fuzzy proportion-integral-derivative (PID) control. The system was composed of a number of independent greenhouse monitoring systems. The server could provide remote monitoring access management services after the collected data were transmitted. The data transmission part of greenhouse was based on ZigBee networking protocol. And the data were sent to intelligent system via gateway connected to the internet. Compared to the classical PID control and fuzzy control, the fuzzy PID control could quickly and accurately adjust the corresponding parameters to the set target. The overshoot was also relatively small. The simulation results showed that the amount of overshoot was reduced 20% compared with classical PID control.
文摘This paper designs a set of ventilation and dust removal in coal mine test device and PLC monitoring system. The ventilation and dust removal test device has a set of ventilation and dust removal functions, can automatically monitor air volume, air pressure, resistance and other performance parameters of ventilator and precipitator. The PLC monitoring system can remotely start and stop the variable frequency speed control on the ventilation machine and dust collector, and it can real-time monitor operation state, such as the running current and the parameters of ventilator and dust collector. The paper simulate and realize computer remote centralized monitoring of underground ventilation for mine ventilation system. The actual application shows that: the system is stable and reliable, simple operation, strong scalability.
文摘Background A patented remote controlled capsule (RCC) has recently been developed to provide noninvasive drug delivery to selected sites in the human gut that allows assessment of regional gastrointestinal (GI) drug absorption under a normal physiological environment. The objective of this study was to investigate the rate and extent of aminophylline absorption after site-specific delivery of the drug in the GI tract using RCC and a magnetic marker monitoring (MMM) technique. Methods This study was conducted in twelve healthy male subjects, in a three-treatment, randomized, crossover manner with a 7-day washout. Eligible subjects received a 150 mg aminophylline dose through an oral administration, or via a remote controlled capsule, delivered to the small bowel or ascending colon. MMM was employed to monitor the GI transit of the RCC, and the radio-frequency signal was used to activate capsules at target sites. Blood samples were obtained at regular intervals until 24 hours post dose/activation. Plasma theophylline concentrations were measured by a TDx~ System Analyzer. A comparison of the PK profile with the oral dosing route of aminophylline was performed after delivery to the small bowel and colon. Results The RCC was well tolerated in volunteers. The mean capsule activation time for the small bowel and ascending colon was 2.07 hours and 6.08 hours post dose. Aminophylline had similar absorption profiles from the small bowel compared with the stomach, with an area under the curve (AUCt) ratio of 92% vs. the stomach, but a lower absorption profile from the ascending colon, with an AUCt ratio of 47.2% vs. the stomach. Conclusions The proprietary of the RCC and MMM technique offer the opportunity to obtain data on the intestinal absorption of a drug in humans under noninvasive conditions. Aminophylline is rapidly and efficiently absorbed from the small bowel. While colonic absorption was limited by the poor water condition although effective absorption was observed from the ascending colon. This provides an opportunity for rational development of modified-release formulations as well as alternative dosage forms.