期刊文献+
共找到646篇文章
< 1 2 33 >
每页显示 20 50 100
HIET:Hybrid Information Enhancement Transformer Network for Single-Photon Image Reconstruction
1
作者 Yiming Liu Xuri Yao +2 位作者 Tao Zhang Yifei Sun Ying Fu 《Journal of Beijing Institute of Technology》 2025年第1期1-17,共17页
Single-photon sensors are novel devices with extremely high single-photon sensitivity and temporal resolution.However,these advantages also make them highly susceptible to noise.Moreover,single-photon cameras face sev... Single-photon sensors are novel devices with extremely high single-photon sensitivity and temporal resolution.However,these advantages also make them highly susceptible to noise.Moreover,single-photon cameras face severe quantization as low as 1 bit/frame.These factors make it a daunting task to recover high-quality scene information from noisy single-photon data.Most current image reconstruction methods for single-photon data are mathematical approaches,which limits information utilization and algorithm performance.In this work,we propose a hybrid information enhancement model which can significantly enhance the efficiency of information utilization by leveraging attention mechanisms from both spatial and channel branches.Furthermore,we introduce a structural feature enhance module for the FFN of the transformer,which explicitly improves the model's ability to extract and enhance high-frequency structural information through two symmetric convolution branches.Additionally,we propose a single-photon data simulation pipeline based on RAW images to address the challenge of the lack of single-photon datasets.Experimental results show that the proposed method outperforms state-of-the-art methods in various noise levels and exhibits a more efficient capability for recovering high-frequency structures and extracting information. 展开更多
关键词 single-photon images hybrid information enhancement structual feature enhancement data simulation pipeline
在线阅读 下载PDF
A counting method for complex overlapping erythrocytes-based microscopic imaging 被引量:2
2
作者 Xudong Wei Yiping Cao +1 位作者 Guangkai Fu Yapin Wang 《Journal of Innovative Optical Health Sciences》 SCIE EI CAS 2015年第6期25-35,共11页
Red blood cell(RBC)counting is a standard medical test that can help diagnose various conditions and diseases.Manual counting of blood cells is highly tedious and time consuming.However,new methods for counting blood ... Red blood cell(RBC)counting is a standard medical test that can help diagnose various conditions and diseases.Manual counting of blood cells is highly tedious and time consuming.However,new methods for counting blood cells are customary employing both electronic and computer-assisted techniques.Image segmentation is a classical task in most image processing applications which can be used to count blood cells in a microscopic image.In this research work,an approach for erythrocytes counting is proposed.We employed a classification before counting and a new segmentation idea was implemented on the complex overlapping clusters in a microscopic smear image.Experimental results show that the proposed method is of higher counting accuracy and it performs much better than most counting algorithms existed in the situation of three or more RBCs overlapping complexly into a group.The average total erythrocytes counting accuracy of the proposed method reaches 92.9%. 展开更多
关键词 Cell counting image processing image segmentation overlap erythrocyte cell classification K-MEANS
在线阅读 下载PDF
Automatic counting method for complex overlapping erythrocytes based on seed prediction in microscopic imaging 被引量:1
3
作者 Xudong Wei Yiping Cao 《Journal of Innovative Optical Health Sciences》 SCIE EI CAS 2016年第5期48-56,共9页
Blood cell counting is an important medical test to help medical staffs diagnose various symptoms and diseascs.An automatic segmentation of complex overlapping erythrocytes based on seed prediction in microscopic imag... Blood cell counting is an important medical test to help medical staffs diagnose various symptoms and diseascs.An automatic segmentation of complex overlapping erythrocytes based on seed prediction in microscopic imaging is proposed.The four main innovations of this ressearch are as.follows:(1)Regions of erythrocytes extracted rapidly and accurately based on the G component.(2)K-means algorithm is applied on edge detection of overlapping erythrocytes.(3)Traces of erythrocytes'biconcave shape are utilized to predict erythrocyte's position in overlapping clus-ters.(4)A new automatic counting method which aims at complex overlapping erythrocytes is presented.The experimental results show that the proposed method is efficient and accurate with very little running time.The average accuracy of the proposed method reaches 97.0%. 展开更多
关键词 image segmentation ERYTHROCYTE cell counting K-MEANS seed prediction
在线阅读 下载PDF
Spatially modulated scene illumination for intensity-compensated two-dimensional array photon-counting LiDAR imaging 被引量:1
4
作者 Jiaheng Xie Zijing Zhang +3 位作者 Mingwei Huang Jiahuan Li Fan Jia Yuan Zhao 《Chinese Physics B》 SCIE EI CAS CSCD 2022年第9期238-248,共11页
Photon-counting LiDAR using a two-dimensional(2D)array detector has the advantages of high lateral resolution and fast acquisition speed.The non-uniform intensity profile of the illumination beam and non-uniform quant... Photon-counting LiDAR using a two-dimensional(2D)array detector has the advantages of high lateral resolution and fast acquisition speed.The non-uniform intensity profile of the illumination beam and non-uniform quantum efficiency of the detectors in the 2D array deteriorate the imaging quality.Herein,we propose a photon-counting LiDAR system that uses a spatial light modulator to control the spatial intensity to compensate for both the non-uniform intensity profile of the illumination beam,and the variation in the quantum efficiency of the detectors in the 2D array.By using a 635 nm peak wavelength and 4 mW average power semiconductor laser,lab-based experiments at a 4.27 m stand-off distance are performed to verify the effectiveness of the proposed method.Compared with the unmodulated method,the standard deviation of the intensity image of the proposed method is reduced from 0.109 to 0.089 for a whiteboard target,with an average signal photon number of 0.006 per pixel. 展开更多
关键词 avalanche photodiode camera photon counting three-dimensional imaging array modulation
在线阅读 下载PDF
Counting of alpha particle tracks on imaging plate based on a convolutional neural network 被引量:1
5
作者 Feng-Di Qin Han-Yu Luo +5 位作者 Zheng-Zhong He Ke-Jun Lu Chuan-Gao Wang Meng-Meng Wu Zhong-Kai Fan Jian Shan 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2023年第3期52-63,共12页
Imaging plates are widely used to detect alpha particles to track information,and the number of alpha particle tracks is affected by the overlapping and fading effects of the track information.In this study,an experim... Imaging plates are widely used to detect alpha particles to track information,and the number of alpha particle tracks is affected by the overlapping and fading effects of the track information.In this study,an experiment and a simulation were used to calibrate the efficiency parameter of an imaging plate,which was used to calculate the grayscale.Images were created by using grayscale,which trained the convolutional neural network to count the alpha tracks.The results demonstrated that the trained convolutional neural network can evaluate the alpha track counts based on the source and background images with a wider linear range,which was unaffected by the overlapping effect.The alpha track counts were unaffected by the fading effect within 60 min,where the calibrated formula for the fading effect was analyzed for 132.7 min.The detection efficiency of the trained convolutional neural network for inhomogeneous ^(241)Am sources(2π emission)was 0.6050±0.0399,whereas the efficiency curve of the photo-stimulated luminescence method was lower than that of the trained convolutional neural network. 展开更多
关键词 imaging plate Convolutional neural network Alpha tracks counting
在线阅读 下载PDF
An FPGA-Based Pulse Pile-up Rejection Technique for Photon Counting Imaging Detectors
6
作者 胡坤 李锋 +2 位作者 陈炼 梁福田 金革 《Chinese Physics Letters》 SCIE CAS CSCD 2015年第3期26-29,共4页
A novel FPGA-based pulse pile-up rejection method for single photon imaging detectors is reported. Tile method is easy to implement in FPGAs for real-time data processing. The rejection principle and entire design are... A novel FPGA-based pulse pile-up rejection method for single photon imaging detectors is reported. Tile method is easy to implement in FPGAs for real-time data processing. The rejection principle and entire design are introduced in detail. The photon counting imaging detector comprises a micro-channel plate (MCP) stack, and a wedge and strip anode (WSA). The resolution mask pattern in front of the MCP can be reconstructed after data processing in the FPGA. For high count rates, the rejection design can effectively reduce the impact of the pulse pile-up on the image. The resolution can reach up to 140μm. The pulse pile-up rejection design can also be applied to high-energy physics and particle detection. 展开更多
关键词 An FPGA-Based Pulse Pile-up Rejection Technique for Photon counting imaging Detectors
在线阅读 下载PDF
Automated Counting of Rice Planthoppers in Paddy Fields Based on Image Processing 被引量:18
7
作者 YAO Qing XIAN Ding-xiang +3 位作者 LIU Qing-jie YANG Bao-jun DIAO Guang-qiang TANG Jian 《Journal of Integrative Agriculture》 SCIE CAS CSCD 2014年第8期1736-1745,共10页
A quantitative survey of rice planthoppers in paddy fields is important to assess the population density and make forecasting decisions. Manual rice planthopper survey methods in paddy fields are time-consuming, fatig... A quantitative survey of rice planthoppers in paddy fields is important to assess the population density and make forecasting decisions. Manual rice planthopper survey methods in paddy fields are time-consuming, fatiguing and tedious. This paper describes a handheld device for easily capturing planthopper images on rice stems and an automatic method for counting rice planthoppers based on image processing. The handheld device consists of a digital camera with WiFi, a smartphone and an extrendable pole. The surveyor can use the smartphone to control the camera, which is fixed on the front of the pole by WiFi, and to photograph planthoppers on rice stems. For the counting of planthoppers on rice stems, we adopt three layers of detection that involve the following:(a) the first layer of detection is an AdaBoost classifier based on Haar features;(b) the second layer of detection is a support vector machine(SVM) classifier based on histogram of oriented gradient(HOG) features;(c) the third layer of detection is the threshold judgment of the three features. We use this method to detect and count whiteback planthoppers(Sogatella furcifera) on rice plant images and achieve an 85.2% detection rate and a 9.6% false detection rate. The method is easy, rapid and accurate for the assessment of the population density of rice planthoppers in paddy fields. 展开更多
关键词 insect counting rice planthoppers handheld device AdaBoost classifier SVM classifier image features
在线阅读 下载PDF
Modeling the photon counting and photoelectron counting characteristics of quanta image sensors 被引量:1
8
作者 Bowen Liu Jiangtao Xu 《Journal of Semiconductors》 EI CAS CSCD 2021年第6期25-34,共10页
A signal chain model of single-bit and multi-bit quanta image sensors(QISs)is established.Based on the proposed model,the photoresponse characteristics and signal error rates of QISs are investigated,and the effects o... A signal chain model of single-bit and multi-bit quanta image sensors(QISs)is established.Based on the proposed model,the photoresponse characteristics and signal error rates of QISs are investigated,and the effects of bit depth,quantum efficiency,dark current,and read noise on them are analyzed.When the signal error rates towards photons and photoelectrons counting are lower than 0.01,the high accuracy photon and photoelectron counting exposure ranges are determined.Furthermore,an optimization method of integration time to ensure that the QIS works in these high accuracy exposure ranges is presented.The trade-offs between pixel area,the mean value of incident photons,and integration time under different illuminance level are analyzed.For the 3-bit QIS with 0.16 e-/s dark current and 0.21 e-r.m.s.read noise,when the illuminance level and pixel area are 1 lux and 1.21μm^(2),or 10000 lux and 0.21μm^(2),the recommended integration time is 8.8 to 30 ms,or 10 to21.3μs,respectively.The proposed method can guide the design and operation of single-bit and multi-bit QISs. 展开更多
关键词 CMOS image sensor quanta image sensor photon counting photoelectron counting signal error rate integration time
在线阅读 下载PDF
ASSESSMENT OF MYOCARDIAL VIABILITY WITH CONTRAST-ENHANCED MAGNETIC RESONANCE IMAGING AND COMPARISON WITH SINGLE-PHOTON EMISSION COMPUTED TOMOGRAPHY
9
作者 Yi-ning Wang Zheng-yu Jin +6 位作者 Zhu-hua Zhang Ling-yan Kong Li-bo Chen Lu Zhou Hong-yi Sun Heng Zhang Qi Miao 《Chinese Medical Sciences Journal》 CAS CSCD 2006年第4期239-244,共6页
Objective To compare contrast-enhanced magnetic resonance imaging (ceMRI) with nuclear metabolic imaging for the assessment of myocardial viability in patients with chronic ischemic heart disease. Methods Twenty pa... Objective To compare contrast-enhanced magnetic resonance imaging (ceMRI) with nuclear metabolic imaging for the assessment of myocardial viability in patients with chronic ischemic heart disease. Methods Twenty patients with suspected chronic ischemic heart disease underwent ceMRI and technetium-99m sestamibi single-photon emission computed tomography (SPECT). Patients with positive SPECT results also underwent 18 F-fluorodeoxyglucose (FDG) SPECT. In a 17-segment model, the segmental extent of hyperenhancement (SEH) by ceMRI was compared with segmental FDG and sestamibi uptake by SPECT. Correlation between the extent of hyperenhancement by ceMRI and left ventricular function was analyzed. Seven patients got negative results both in ceMRI and technetium-99m sestamibi SPECT. The rest 13 patients with positive results then underwent ^18F-FDG SPECT. In 221 segments of 13 patients, SEH was (2. 1±8.2)%, (25.0±13.7 )%, and (57. 7±23.6 )% in segments with normal metabolism/perfusion, metabolism/perfusion mismatch, and matched defects, respectively, and there were significant differences between either two of them ( all P 〈 0.05). By receiver operating characteristic curve analysis, the area under the curve was 0. 95 for the differentiation between viable and non-viable segments. At the cutoff value of 34%, SEH optimally differentiated viable from non-viable segments defined by SPECT. Using this threshold, the sensitivity and specificity of ceMRI to detect non-viable myocardium as defined by SPECT were 92% and 93%, respectively. Hyperenhancement size by ceMRI was correlated negatively with the left ventricular ejection fraction ( r = - 0.90, P 〈 0.01 ) and positively with left ventricular volumes ( r = 0. 62 for end-diastolic volume, r = 0.75 for end-systolic volume, both P 〈 0.05 ). Conclusion CeMRI allows assessment of myocardial viability with a high accuracy in patients with chronic ischemic heart disease. 展开更多
关键词 magnetic resonance imaging single-photon emission computed tomography myocardialviability
在线阅读 下载PDF
Fast fluorescence lifetime imaging techniques:A review on challenge and development 被引量:2
10
作者 Xiongbo Liu Danying Lin +4 位作者 Wolfgang Becker Jingjing Niu Bin Yu Liwei Liu Junle Qu 《Journal of Innovative Optical Health Sciences》 SCIE EI CAS 2019年第5期3-29,共27页
Fluorescence lifetime imaging microscopy(FLIM)is increasingly used in biomedicine,material science,chemistry,and other related research fields,because of its advantages of high specificity and sensitivity in monitorin... Fluorescence lifetime imaging microscopy(FLIM)is increasingly used in biomedicine,material science,chemistry,and other related research fields,because of its advantages of high specificity and sensitivity in monitoring cellular microenvironments,studying interaction between proteins,metabolic state,screening drugs and analyzing their efficacy,characterizing novel materials,and diagnosing early cancers.Understandably,there is a large interest in obtaining FLIM data within an acquisition time as short as possible.Consequently,there is currently a technology that advances towards faster and faster FLIM recording.However,the maximum speed of a recording technique is only part of the problerm.The acquisition time of a FLIM image is a complex function of many factors.These include the photon rate that can be obtained from the sample,the amount of information a technique extracts from the decay functions,the fficiency at which it determines fluorescence decay parameters from the recorded photons,the demands for the accuracy of these parameters,the number of pixels,and the lateral and axial resolutions that are obtained in biological materials.Starting from a discussion of the parameters which determine the acquisition time,this review will describe existing and emerging FLIM techniques and data analysis algo-rithms,and analyze their performance and recording speed in biological and biomedical applications. 展开更多
关键词 Fluorescence lifetime imaging microscopy(FLIM) acquisitin time imaging speed dead time photon fficiency time domain frequency domain scanning wide-field imaging time-correlated single photon counting(TCSPC) gated detection gated image intensifer modulated inage intensifier SPAD array detector
在线阅读 下载PDF
Imaging properties of a tetra wedge readout
11
作者 刘永安 鄢秋荣 +5 位作者 赛小锋 韦永林 盛立志 杨颢 胡慧君 赵宝升 《Chinese Physics B》 SCIE EI CAS CSCD 2011年第6期534-539,共6页
The decoding principle of a tetra wedge anode, which is a development of the wedge and strip anode, is described. The influence of charge cloud size on decoding accuracy is studied using the Monte Carlo method. Simula... The decoding principle of a tetra wedge anode, which is a development of the wedge and strip anode, is described. The influence of charge cloud size on decoding accuracy is studied using the Monte Carlo method. Simulation results show that the decoding error is large when the size of charge clouds collected by the anode is small. Thus, the charge clouds collected by the tetra wedge anode should reach a necessary size to ensure accurate decoding. Finally, using the ultraviolet photon counting imaging system, the linearity and the spatial resolution of the system are tested. Experimental results show that the system has a good linearity and the spatial resolution is better than 100 μm. 展开更多
关键词 detectors photon counting imaging tetra wedge anode microchannel plate
在线阅读 下载PDF
Dark count in single-photon avalanche diodes:A novel statistical behavioral model
12
作者 Wen-Juan Yu Yu Zhang +1 位作者 Ming-Zhu Xu Xin-Miao Lu 《Chinese Physics B》 SCIE EI CAS CSCD 2020年第4期523-529,共7页
Dark count is one of the inherent noise types in single-photon diodes,which may restrict the performances of detectors based on these diodes.To formulate better designs for peripheral circuits of such diodes,an accura... Dark count is one of the inherent noise types in single-photon diodes,which may restrict the performances of detectors based on these diodes.To formulate better designs for peripheral circuits of such diodes,an accurate statistical behavioral model of dark current must be established.Research has shown that there are four main mechanisms that contribute to the dark count in single-photon avalanche diodes.However,in the existing dark count models only three models have been considered,thus leading to inaccuracies in these models.To resolve these shortcomings,the dark current caused by carrier diffusion in the neutral region is deduced by multiplying the carrier detection probability with the carrier particle current at the boundary of the depletion layer.Thus,a comprehensive dark current model is constructed by adding the dark current caused by carrier diffusion to the dark current caused by the other three mechanisms.To the best of our knowledge,this is the first dark count simulation model into which incorporated simultaneously are the thermal generation,trap-assisted tunneling,band-to-band tunneling mechanisms,and carrier diffusion in neutral regions to evaluate dark count behavior.The comparison between the measured data and the simulation results from the models shows that the proposed model is more accurate than other existing models,and the maximum of accuracy increases up to 31.48%when excess bias voltage equals 3.5 V and temperature is 50℃. 展开更多
关键词 single-photon AVALANCHE diode DARK count STATISTICAL BEHAVIORAL modeling carrier diffusion
在线阅读 下载PDF
Automatic counting of microglial cell activation and its applications
13
作者 Beatriz I.Gallego Collado Pablo de Gracia 《Neural Regeneration Research》 SCIE CAS CSCD 2016年第8期1212-1215,共4页
Glaucoma is a multifactorial optic neuropathy characterized by the damage and death of the retinal ganglion cells.This disease results in vision loss and blindness.Any vision loss resulting from the disease cannot be ... Glaucoma is a multifactorial optic neuropathy characterized by the damage and death of the retinal ganglion cells.This disease results in vision loss and blindness.Any vision loss resulting from the disease cannot be restored and nowadays there is no available cure for glaucoma; however an early detection and treatment,could offer neuronal protection and avoid later serious damages to the visual function.A full understanding of the etiology of the disease will still require the contribution of many scientific efforts.Glial activation has been observed in glaucoma,being microglial proliferation a hallmark in this neurodegenerative disease.A typical project studying these cellular changes involved in glaucoma often needs thousands of images- from several animals- covering different layers and regions of the retina.The gold standard to evaluate them is the manual count.This method requires a large amount of time from specialized personnel.It is a tedious process and prone to human error.We present here a new method to count microglial cells by using a computer algorithm.It counts in one hour the same number of images that a researcher counts in four weeks,with no loss of reliability. 展开更多
关键词 GLAUCOMA glial cells microglial cells automatic counting image processing inner plexiform layer outer plexiform layer bilateral activation
在线阅读 下载PDF
On the Pollen Detection with Photoacoustic Imaging
14
作者 Tsutomu Hoshimiya 《American Journal of Plant Sciences》 2013年第7期29-32,共4页
A photoacoustic (PA) imaging that utilizes acoustic detection of sound generated by a specimen due to the absorption of modulated light was applied to measure the amount of the pollen of the Cryptomeria japonica, Asia... A photoacoustic (PA) imaging that utilizes acoustic detection of sound generated by a specimen due to the absorption of modulated light was applied to measure the amount of the pollen of the Cryptomeria japonica, Asian allergic plant. High-sensitivity PA imaging can measure pollen particles with a large dynamic range from single particle to several hundred micrograms. The PA signal dependence on the amount of the pollen showed good correlation with the amount of pollen. 展开更多
关键词 POLLEN counting PHOTOACOUSTIC MICROSCOPE imaging
在线阅读 下载PDF
Fiber coupled high count-rate single-photon generated from InAs quantum dots
15
作者 Yao Chen Shulun Li +7 位作者 Xiangjun Shang Xiangbin Su Huiming Hao Jiaxin Shen Yu Zhang Haiqiao Ni Ying Ding Zhichuan Niu 《Journal of Semiconductors》 EI CAS CSCD 2021年第7期83-87,共5页
In this work,we achieve high count-rate single-photon output in single-mode(SM)optical fiber.Epitaxial and dilute InAs/GaAs quantum dots(QDs)are embedded in a GaAs/AlGaAs distributed Bragg reflector(DBR)with a micro-p... In this work,we achieve high count-rate single-photon output in single-mode(SM)optical fiber.Epitaxial and dilute InAs/GaAs quantum dots(QDs)are embedded in a GaAs/AlGaAs distributed Bragg reflector(DBR)with a micro-pillar cavity,so as to improve their light emission extraction in the vertical direction,thereby enhancing the optical SM fiber’s collection capabil-ity(numerical aperture:0.13).By tuning the temperature precisely to make the quantum dot exciton emission resonant to the micro-pillar cavity mode(Q~1800),we achieve a fiber-output single-photon count rate as high as 4.73×10^(6) counts per second,with the second-order auto-correlation g2(0)remaining at 0.08. 展开更多
关键词 single-photon source fiber-output high count rate
在线阅读 下载PDF
Analysis of Wide-Bandgap Material OPFET UV Detectors for High Dynamic Range Imaging and Communication Applications
16
作者 Jaya V. Gaitonde Rajesh B. Lohani 《Communications and Network》 2019年第4期83-117,共35页
The ultraviolet (UV) photoresponses of Wurtzite GaN, ZnO, and 6H-SiC-based Optical Field Effect Transistor (OPFET) detectors are estimated with an in-depth analysis of the same considering the generalized model and th... The ultraviolet (UV) photoresponses of Wurtzite GaN, ZnO, and 6H-SiC-based Optical Field Effect Transistor (OPFET) detectors are estimated with an in-depth analysis of the same considering the generalized model and the front-illuminated model for high resolution imaging and UV communication applications. The gate materials considered for the proposed study are gold (Au) and Indium-Tin-Oxide (ITO) for GaN, Au for SiC, and Au and silver dioxide (AgO2) for ZnO. The results indicate significant improvement in the Linear Dynamic Range (LDR) over the previously investigated GaN OPFET (buried-gate, front-illuminated and generalized) models with Au gate. The generalized model has superior dynamic range than the front-illuminated model. In terms of responsivity, all the models including buried-gate OPFET exhibit high and comparable photoresponses. Buried-gate devices on the whole, exhibit faster response than the surface gate models except in the AgO2-ZnO generalized OPFET model wherein the switching time is the lowest. The generalized model enables faster switching than the front-illuminated model. The switching times in all the cases are of the order of nanoseconds to picoseconds. The SiC generalized OPFET model shows the highest 3-dB bandwidths of 11.88 GHz, 36.2 GHz, and 364 GHz, and modest unity-gain cut-off frequencies of 4.62 GHz, 8.71 GHz, and 5.71 GHz at the optical power densities of 0.575 μW/cm2, 0.575 mW/cm2, and 0.575 W/cm2 respectively. These are in overall, the highest detection-cum-amplifi-cation bandwidths among all the investigated devices. The same device exhibits the highest LDR of 73.3 dB. The device performance is superior to most of the other existing detectors along with comparable LDR, thus, emerging as a high performance photodetector for imaging and communication applications. All the detectors show considerably high detectivities owing to the high responsivity values. The results have been analyzed by the photovoltaic and the photoconductive effects, and the series resistance effects and will aid in conducting further research. The results are in line with the experiments and the commercially available software simulations. The devices will greatly contribute towards single photon counting, high resolution imaging, and UV communication applications. 展开更多
关键词 UV OPFET GaN SiC ZnO Au ITO AgO2 High Dynamic Range imaging PHOTON counting COMMUNICATION
在线阅读 下载PDF
A new software for automated counting of glistenings in intraocular lenses in vivo
17
作者 Nick Stanojcic Christopher C.Hull +2 位作者 Eduardo Mangieri Nathan Little David O’Brart 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2023年第8期1237-1242,共6页
AIM:To assess the performance of a bespoke software for automated counting of intraocular lens(IOL)glistenings in slit-lamp images.METHODS:IOL glistenings from slit-lamp-derived digital images were counted manually an... AIM:To assess the performance of a bespoke software for automated counting of intraocular lens(IOL)glistenings in slit-lamp images.METHODS:IOL glistenings from slit-lamp-derived digital images were counted manually and automatically by the bespoke software.The images of one randomly selected eye from each of 34 participants were used as a training set to determine the threshold setting that gave the best agreement between manual and automatic grading.A second set of 63 images,selected using randomised stratified sampling from 290 images,were used for software validation.The images were obtained using a previously described protocol.Software-derived automated glistenings counts were compared to manual counts produced by three ophthalmologists.RESULTS:A threshold value of 140 was determined that minimised the total deviation in the number of glistenings for the 34 images in the training set.Using this threshold value,only slight agreement was found between automated software counts and manual expert counts for the validating set of 63 images(κ=0.104,95%CI,0.040-0.168).Ten images(15.9%)had glistenings counts that agreed between the software and manual counting.There were 49 images(77.8%)where the software overestimated the number of glistenings.CONCLUSION:The low levels of agreement show between an initial release of software used to automatically count glistenings in in vivo slit-lamp images and manual counting indicates that this is a non-trivial application.Iterative improvement involving a dialogue between software developers and experienced ophthalmologists is required to optimise agreement.The results suggest that validation of software is necessary for studies involving semi-automatic evaluation of glistenings. 展开更多
关键词 new software automated counting glistenings intraocular lenses slit-lamp images
在线阅读 下载PDF
Research on the correlation between the dual diffusion behavior of zinc in InGaAs/InP single-photon avalanche photodiodes and device performance
18
作者 LIU Mao-Fan YU Chun-Lei +7 位作者 MA Ying-Jie YU Yi-Zhen YANG Bo TIAN Yu BAO Peng-Fei CAO Jia-Sheng LIU Yi LI Xue 《红外与毫米波学报》 SCIE EI CAS CSCD 北大核心 2024年第5期595-602,共8页
The development of InGaAs/InP single-photon avalanche photodiodes(SPADs)necessitates the utiliza-tion of a two-element diffusion technique to achieve accurate manipulation of the multiplication width and the dis-tribu... The development of InGaAs/InP single-photon avalanche photodiodes(SPADs)necessitates the utiliza-tion of a two-element diffusion technique to achieve accurate manipulation of the multiplication width and the dis-tribution of its electric field.Regarding the issue of accurately predicting the depth of diffusion in InGaAs/InP SPAD,simulation analysis and device development were carried out,focusing on the dual diffusion behavior of zinc atoms.A formula of X_(j)=k√t-t_(0)+c to quantitatively predict the diffusion depth is obtained by fitting the simulated twice-diffusion depths based on a two-dimensional(2D)model.The 2D impurity morphologies and the one-dimensional impurity profiles for the dual-diffused region are characterized by using scanning electron micros-copy and secondary ion mass spectrometry as a function of the diffusion depth,respectively.InGaAs/InP SPAD devices with different dual-diffusion conditions are also fabricated,which show breakdown behaviors well consis-tent with the simulated results under the same junction geometries.The dark count rate(DCR)of the device de-creased as the multiplication width increased,as indicated by the results.DCRs of 2×10^(6),1×10^(5),4×10^(4),and 2×10^(4) were achieved at temperatures of 300 K,273 K,263 K,and 253 K,respectively,with a bias voltage of 3 V,when the multiplication width was 1.5µm.These results demonstrate an effective prediction route for accu-rately controlling the dual-diffused zinc junction geometry in InP-based planar device processing. 展开更多
关键词 InGaAs/InP single-photon avalanche photodiode diffusion depth Znic diffusion dark count rate
在线阅读 下载PDF
X-ray photon counting detectors for preclinical and clinical applications
19
作者 REN Liqiang LIU Hong 《Instrumentation》 2016年第4期43-54,共12页
Photon counting detectors(PCDs) have attained w ide use in X-ray imaging for various preclinical and clinical applications in the past decade. This paper briefly review s the preclinical and clinical applications of P... Photon counting detectors(PCDs) have attained w ide use in X-ray imaging for various preclinical and clinical applications in the past decade. This paper briefly review s the preclinical and clinical applications of PCDs based X-ray imaging systems.Starting with an introduction of X-ray single photon detection mechanism,the brief review first describes tw o major advantages of utilizing PCDs: photon energy resolving capability and electronic noise elimination. Compared to energy integrating detectors(EIDs),the aforementioned advantages make PCDs more favorable in X-ray imaging with profound benefits such as enhanced tissue contrast,decreased image noise,increased signal to noise ratio,decreased radiation dose to the small animals and patients,and more accurate material decomposition. The utilizations of PCDs in X-ray projection radiography and computed tomography(CT)including micro-CT,dedicated breast CT,K-edge CT,and clinical CT are then review ed for the imaging applications ranging from phantoms to small animals and humans. In addition,optimization methods aiming to improve the imaging performance using PCDs are briefly review ed. PCDs are not flaw less though,and their limitations are also discussed in this review. Nevertheless,PCDs may continuously contribute to the advancement of X-ray imaging techniques in future preclinical and clinical applications. 展开更多
关键词 Photon counting detectors(PCDs) energy integrating detectors(EIDs) X-ray imaging systems preclinical and clinical application
在线阅读 下载PDF
Comparison of clinical value of dynamic contrast-enhanced MRI and SPECT renal dynamic imaging of GFR measurement in the evaluation of renal function in renal transplantation
20
作者 Hong G Dan L Yunhe L 《Discussion of Clinical Cases》 2019年第2期7-11,共5页
Objective:To compare the clinical value of dynamic contrast-enhanced MRI(DCE-MRI)and single-photon emission computed tomography(SPECT)renal dynamic imaging in the measurement of glomerular filtration rate(GFR)in the e... Objective:To compare the clinical value of dynamic contrast-enhanced MRI(DCE-MRI)and single-photon emission computed tomography(SPECT)renal dynamic imaging in the measurement of glomerular filtration rate(GFR)in the evaluation of renal function in renal transplantation.Methods:A total of 70 recipients who underwent renal transplantation in Baogang Hospital of Inner Mongolia from April of 2015 to April of 2018 were selected as research objects.GFR was measured in renal transplant recipients by use of DCE-MRI and SPECT(GFR-MRI and GFR-SPECT respectively),and was compared with creatinine clearance rate(Ccr).The safety of contrast media was evaluated in DCE-MRI detection.Results:The bias of GFR-MRI against Ccr value was higher than that of GFR-SPECT against Ccr value,with 30%and 50%accuracy of GFR-MRI higher than that of GFR-SPECT,and the difference was statistically significant(p<.05).Pearson correlation analysis showed that GFR-MRI and GFR-SPECT values were positively correlated to Ccr(p<.05),and the correlation coefficient of GFR-MRI and Ccr was higher than that of GFR-SPECT and Ccr,with the difference statistically significant(p<.05).By Bland-Altman analysis,95%confidence interval of GFR-SPECT was 95.49 ml/(min·1.73 m^(2)),and 95%confidence interval of GFR-MRI was 62.35 ml/(min·1.73m^(2)),which was much narrower.Only 2 cases of patients developed mild rash among 70 cases of patients,and recovered spontaneously without any treatment.Conclusions:Compared with SPECT,the bias of GFR measured by DCE-MRI against Ccr is much greater.However,DCE-MRI has a higher accuracy,correlation and consistency in comparison with Ccr,and it has a narrower confidence interval.DCE-MRI can more accurately evaluate renal function in renal transplantation by measuring GFR,and it has a high safety. 展开更多
关键词 Renal transplantation Dynamic contrast-enhanced MRI single-photon emission computed tomography Renal dynamic imaging
在线阅读 下载PDF
上一页 1 2 33 下一页 到第