A laser collimating system based on 2-D position sensitive detector (PSD) is presented in this paper. The working principle of PSD is depicted in detail. A calibration device was developed to check the nonlinearity er...A laser collimating system based on 2-D position sensitive detector (PSD) is presented in this paper. The working principle of PSD is depicted in detail. A calibration device was developed to check the nonlinearity errors of PSD and a multilayer feedforward neural network based on error back-propagation algorithm was used to compensate errors. With the aid of computer-based data acquisition system, an automatic dynamic measuring process was realized. A series of experiments, including comparison tests with laser interferometer, were done to evaluate the performance of the measuring system. The experimental results show that the spatial straightness errors of guide rails can be measured with high accuracy. The maximum differences between the device and laser interferometer are 0.027 mm in Y direction, and 0.053 mm in X direction in the measuring distance of 6 m.展开更多
Soil water retention data are essential for irrigation scheduling and determination of irrigation frequency. However, direct measurement of this characteristic is time consuming and expensive and furthermore its spati...Soil water retention data are essential for irrigation scheduling and determination of irrigation frequency. However, direct measurement of this characteristic is time consuming and expensive and furthermore its spatial and temporal variabilities in field scales increase the number of measurements. Different pedotransfer functions, such as Saxton et al., Campbell, Vereecken et al., l^awls and Brakensiek, WSsten et al., Rajkni et al., Ghorbani Dashtaki and Homaee, Zacharias and Wessolek, and Rosetta, were evaluated to estimate soil water retention of saline and saline-alkali soils collected from south of Tehran, Iran. The saturation-extract conductivity of all the 68 samples and exchangeable sodium percentage of more than half of them were measured to be greater than 4 dS m-1 and 15%, respectively. The calculated Akaike's information criterion values showed that Saxton et al. and Campbell models were the best in estimation of soil water retention curve and total available water, respectively.展开更多
In this paper,we propose a roll angle measurement method with a large range based on the photoelectronic autocollimator.According to the corresponding relationship between the rotation position of the measured shaft a...In this paper,we propose a roll angle measurement method with a large range based on the photoelectronic autocollimator.According to the corresponding relationship between the rotation position of the measured shaft and the spot position on the circular trajectory,the roll angle is calculated quickly and conveniently using a simple algorithm.Only a mirror,a coupler and a fine shaft are contained in the measurement system besides the photoelectronic autocollimator.Aiming at the terrible measurement error induced by the axis wobbly error,two measurement schemes are proposed,which are linking the fine precision shaft to the measured shaft for reducing the axis wobbly error and using the segment measurement to enlarge the radius of the circular trajectory.The experimental results show that the measurement error is decreased by ±0.38°.The roll angle error of the mechanism is ±0.14°,and the measurement precision is about ±2′.The proposed method can be widely used in the engineering fields.展开更多
We investigate a second order parabolic parametrization, w(a) = wt + wa(at - a)2, which is a direct characterization of a possible turning in w. The cosmological consequence of this parametrization is explored by...We investigate a second order parabolic parametrization, w(a) = wt + wa(at - a)2, which is a direct characterization of a possible turning in w. The cosmological consequence of this parametrization is explored by using the observational data of the SNLS3 type Ia supernovae sample, the CMB measurements from WMAP9 and Planck, the Hubble parameter measurement from HST, and the baryon acoustic oscillation (BAO) measurements from 6dFGS, BOSS DRI 1 and improved WiggleZ. We found the existence of a turning point in w at a - 0.7 is favored at 10- CL. In the epoch 0.55 〈 a 〈 0.9, w 〈 -1 is favored at 10- CL, and this significance increases near a - 0.8, reaching a 20- CL. The parabolic parametrization achieve equivalent performance to the ACDM and Chevallier-Polarski-Linder (CPL) models when the Akaike information criterion was used to assess them. Our analysis shows the value of considering high order parametrizations when studying the cosmological constraints on w.展开更多
文摘A laser collimating system based on 2-D position sensitive detector (PSD) is presented in this paper. The working principle of PSD is depicted in detail. A calibration device was developed to check the nonlinearity errors of PSD and a multilayer feedforward neural network based on error back-propagation algorithm was used to compensate errors. With the aid of computer-based data acquisition system, an automatic dynamic measuring process was realized. A series of experiments, including comparison tests with laser interferometer, were done to evaluate the performance of the measuring system. The experimental results show that the spatial straightness errors of guide rails can be measured with high accuracy. The maximum differences between the device and laser interferometer are 0.027 mm in Y direction, and 0.053 mm in X direction in the measuring distance of 6 m.
文摘Soil water retention data are essential for irrigation scheduling and determination of irrigation frequency. However, direct measurement of this characteristic is time consuming and expensive and furthermore its spatial and temporal variabilities in field scales increase the number of measurements. Different pedotransfer functions, such as Saxton et al., Campbell, Vereecken et al., l^awls and Brakensiek, WSsten et al., Rajkni et al., Ghorbani Dashtaki and Homaee, Zacharias and Wessolek, and Rosetta, were evaluated to estimate soil water retention of saline and saline-alkali soils collected from south of Tehran, Iran. The saturation-extract conductivity of all the 68 samples and exchangeable sodium percentage of more than half of them were measured to be greater than 4 dS m-1 and 15%, respectively. The calculated Akaike's information criterion values showed that Saxton et al. and Campbell models were the best in estimation of soil water retention curve and total available water, respectively.
基金supported by the National Natural Science Foundation of China(Nos.111742741117427961205021 and 11204299)
文摘In this paper,we propose a roll angle measurement method with a large range based on the photoelectronic autocollimator.According to the corresponding relationship between the rotation position of the measured shaft and the spot position on the circular trajectory,the roll angle is calculated quickly and conveniently using a simple algorithm.Only a mirror,a coupler and a fine shaft are contained in the measurement system besides the photoelectronic autocollimator.Aiming at the terrible measurement error induced by the axis wobbly error,two measurement schemes are proposed,which are linking the fine precision shaft to the measured shaft for reducing the axis wobbly error and using the segment measurement to enlarge the radius of the circular trajectory.The experimental results show that the measurement error is decreased by ±0.38°.The roll angle error of the mechanism is ±0.14°,and the measurement precision is about ±2′.The proposed method can be widely used in the engineering fields.
基金supported by the National Natural Science Foundation of China (Grant Nos. 11275247 and 11335012)XDL acknowledges suport from the KDES program
文摘We investigate a second order parabolic parametrization, w(a) = wt + wa(at - a)2, which is a direct characterization of a possible turning in w. The cosmological consequence of this parametrization is explored by using the observational data of the SNLS3 type Ia supernovae sample, the CMB measurements from WMAP9 and Planck, the Hubble parameter measurement from HST, and the baryon acoustic oscillation (BAO) measurements from 6dFGS, BOSS DRI 1 and improved WiggleZ. We found the existence of a turning point in w at a - 0.7 is favored at 10- CL. In the epoch 0.55 〈 a 〈 0.9, w 〈 -1 is favored at 10- CL, and this significance increases near a - 0.8, reaching a 20- CL. The parabolic parametrization achieve equivalent performance to the ACDM and Chevallier-Polarski-Linder (CPL) models when the Akaike information criterion was used to assess them. Our analysis shows the value of considering high order parametrizations when studying the cosmological constraints on w.