Accurate mass measurements of 20 drugs were conducted using MassWorks software on a TSQ Quantum Ultra mass spectrometer. All Q1 scan mass spectral data were collected in profile mode with full width at half-maximum(F...Accurate mass measurements of 20 drugs were conducted using MassWorks software on a TSQ Quantum Ultra mass spectrometer. All Q1 scan mass spectral data were collected in profile mode with full width at half-maximum(FWHM) set at 0.7 Da.The mass errors of all 20 drugs(molecular weight between 135 and 810) were within the range from-22.4×10-6 to 36.1×10-6,among them 90% of the drugs achieved a mass accuracy better than 10×10-6.The new method can provide accurate mass measurements on unit mass resolution mass spectrometers.展开更多
The chloride ion contained in reinforced concrete seriously corrodes the steel surface and damages concrete, resulting in inferior reinforced concrete that strength seriously compromises the entire structure’s safety...The chloride ion contained in reinforced concrete seriously corrodes the steel surface and damages concrete, resulting in inferior reinforced concrete that strength seriously compromises the entire structure’s safety. Consequently, the examination of chloride ions contained in reinforced concrete becomes an important part of a complete quality control procedure. To effectively check the concentration of chloride ions in concrete, the evaluation process should be accurate and precise. Laboratory data ob- tained using existing evaluation methods for the examination of chloride ion are not sufficiently objective to yield reliable results with accuracy and consistency for each sample. An evaluation algorithm with capability to define indices of precision degree (Ep) and accuracy degree (Ea) is presented in this paper. The authors established a statistically reliable index of unbiased estimators and equations to critically examine the laboratory methods’ precision, accuracy degrees and application value for measuring chlorine ion concentration in reinforced concrete.展开更多
文摘Accurate mass measurements of 20 drugs were conducted using MassWorks software on a TSQ Quantum Ultra mass spectrometer. All Q1 scan mass spectral data were collected in profile mode with full width at half-maximum(FWHM) set at 0.7 Da.The mass errors of all 20 drugs(molecular weight between 135 and 810) were within the range from-22.4×10-6 to 36.1×10-6,among them 90% of the drugs achieved a mass accuracy better than 10×10-6.The new method can provide accurate mass measurements on unit mass resolution mass spectrometers.
基金Project (No. NSC-93-2211-E-167-002) supported by the NationalScience Council of Taiwan China
文摘The chloride ion contained in reinforced concrete seriously corrodes the steel surface and damages concrete, resulting in inferior reinforced concrete that strength seriously compromises the entire structure’s safety. Consequently, the examination of chloride ions contained in reinforced concrete becomes an important part of a complete quality control procedure. To effectively check the concentration of chloride ions in concrete, the evaluation process should be accurate and precise. Laboratory data ob- tained using existing evaluation methods for the examination of chloride ion are not sufficiently objective to yield reliable results with accuracy and consistency for each sample. An evaluation algorithm with capability to define indices of precision degree (Ep) and accuracy degree (Ea) is presented in this paper. The authors established a statistically reliable index of unbiased estimators and equations to critically examine the laboratory methods’ precision, accuracy degrees and application value for measuring chlorine ion concentration in reinforced concrete.