In this paper, we proposed a novel resolution criterion(improved calibrated normalized resolution product, r*') to evaluate separation quality of fingerprints. By comparing with the calibrated normalized resolutio...In this paper, we proposed a novel resolution criterion(improved calibrated normalized resolution product, r*') to evaluate separation quality of fingerprints. By comparing with the calibrated normalized resolution product(r*) and the hierarchical chromatographic response function(HCRF), the validity of this criterion was demonstrated by experimental chromatograms. The soy isoflavone extract was selected as the analytical object. The initial and end percentages of methanol and elution time affecting gradient elution were tested by orthogonal design. The final optimized conditions were as follows. It was detected by UV absorbance at 254 nm, column temperature was maintained at 36 oC, solvent A was 0.1%(v/v) acetic acid, solvent B was methanol, gradient elution was from 34% to 65% B in a linear gradient in 25 min, and the flow-rate was set at 1.0 m L/min. In addition, the main ingredients of the soy isoflavone extract were confirmed by LC-ESI/MS.展开更多
To balance the convergence rate and steadystate error of blind source separation(BSS) algorithms, an efficient equivariant adaptive separation via independence(Efficient EASI) algorithm is proposed based on separating...To balance the convergence rate and steadystate error of blind source separation(BSS) algorithms, an efficient equivariant adaptive separation via independence(Efficient EASI) algorithm is proposed based on separating indicator, which was derived from the convergence condition of EASI, and can be used to evaluate the separation degree of separated signals. Furthermore, a nonlinear monotone increasing function between suitable step sizes and separating indicator is constructed to adaptively adjust step sizes, and forgetting factor is employed to weaken effects of data at the initial stage. Numerical case studies and experimental studies on a test bed with shell structures are provided to validate the efficiency improvement of the proposed method. This study can benefit for vibration & acoustic monitoring and control, and machinery condition monitoring and fault diagnosis.展开更多
基金National Higher-Education Institution General Research and Development Funding(Grant No.JKP2011010)
文摘In this paper, we proposed a novel resolution criterion(improved calibrated normalized resolution product, r*') to evaluate separation quality of fingerprints. By comparing with the calibrated normalized resolution product(r*) and the hierarchical chromatographic response function(HCRF), the validity of this criterion was demonstrated by experimental chromatograms. The soy isoflavone extract was selected as the analytical object. The initial and end percentages of methanol and elution time affecting gradient elution were tested by orthogonal design. The final optimized conditions were as follows. It was detected by UV absorbance at 254 nm, column temperature was maintained at 36 oC, solvent A was 0.1%(v/v) acetic acid, solvent B was methanol, gradient elution was from 34% to 65% B in a linear gradient in 25 min, and the flow-rate was set at 1.0 m L/min. In addition, the main ingredients of the soy isoflavone extract were confirmed by LC-ESI/MS.
基金supported by the National Natural Science Foundation of China(Grant No.51305329)the China Postdoctoral Science Foundation(Grant No.2014T70911)+1 种基金the Doctoral Foundation of Education Ministry of China(Grant No.20130201120040)Basic Research Project of Natural Science in Shaanxi Province(Grant No.2015JQ5183)
文摘To balance the convergence rate and steadystate error of blind source separation(BSS) algorithms, an efficient equivariant adaptive separation via independence(Efficient EASI) algorithm is proposed based on separating indicator, which was derived from the convergence condition of EASI, and can be used to evaluate the separation degree of separated signals. Furthermore, a nonlinear monotone increasing function between suitable step sizes and separating indicator is constructed to adaptively adjust step sizes, and forgetting factor is employed to weaken effects of data at the initial stage. Numerical case studies and experimental studies on a test bed with shell structures are provided to validate the efficiency improvement of the proposed method. This study can benefit for vibration & acoustic monitoring and control, and machinery condition monitoring and fault diagnosis.