期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
基于动态虚拟电抗的虚拟同步机系统有功环电压动态补偿策略 被引量:2
1
作者 刘亚东 宋新立 +1 位作者 戴汉扬 李东升 《电力科学与工程》 2024年第4期55-64,共10页
为解决新型电力系统中的虚拟同步机(Virtual synchronous generator,VSG)在电网电压跌落时出现的功角暂态失稳和过电流问题,对采用VSG控制的并网换流器暂态控制策略进行了改进。为降低故障期间有功功率的参考值进而实现VSG的功角暂态稳... 为解决新型电力系统中的虚拟同步机(Virtual synchronous generator,VSG)在电网电压跌落时出现的功角暂态失稳和过电流问题,对采用VSG控制的并网换流器暂态控制策略进行了改进。为降低故障期间有功功率的参考值进而实现VSG的功角暂态稳定控制,根据VSG的功角特性、有功功率参考值与功角稳定性之间的关系,引入电压动态补偿,并利用相图曲线理论分析了控制策略参数选取对暂态稳定的影响。为限制故障发生瞬间和故障切除瞬间的冲击电流、保证故障期间VSG系统的暂态功角稳定、实现故障限流,提出了一种以指数形式变化的虚拟电抗模型,确定了虚拟电抗的投切参数。仿真实验结果验证了改进策略的有效性。 展开更多
关键词 新型电力系统 虚拟同步机 暂态稳定 暂态功角控制 动态电压补偿 故障限流 动态虚拟电抗
在线阅读 下载PDF
Investigation of Interline Dynamic Voltage Restorer with Virtual Impedance Injection
2
作者 Ahmed Elserougi Ahmed Hossam-Eldin +1 位作者 Ahmed Massoud Shehab Ahmed 《Journal of Energy and Power Engineering》 2012年第1期101-109,共9页
The inter-line dynamic voltage restorer (IDVR) consists of several voltage source inverters connected to different independent distribution feeders with common dc bus. When one of the inverters compensates for volta... The inter-line dynamic voltage restorer (IDVR) consists of several voltage source inverters connected to different independent distribution feeders with common dc bus. When one of the inverters compensates for voltage sag that appears in its feeder (voltage control mode), the other inverters pump the required power into the dc bus (power control mode). Each inverter will have both voltage and power controllers; only one controller is in use during the abnormal conditions according to its feeder state. The voltage controller uses one of the dynamic voltage restoration techniques. In this paper, the in-phase technique is applied and two types of loads are considered (constant impedance and three phase induction motor). Since the voltage restoration process may need real power injection into the distribution system, the power controller injects this power via voltage injection. This voltage injection is simulated by voltage drop across series virtual impedance. A new scheme is proposed to select the impedance value. The impedance value is selected such that the power consumed by this impedance represents the required power to be transferred without perturbing the load voltage. The performance of this system is also studied during voltage swell. A scheme for operation of multi-feeder IDVR system is proposed in this paper. Simulation results substantiate the proposed concept. 展开更多
关键词 Dynamic voltage restorers IDVR voltage sag voltage swell power quality.
在线阅读 下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部