期刊文献+
共找到5篇文章
< 1 >
每页显示 20 50 100
双波分光光度法测定伤风止咳冲剂中盐酸异丙嗪的含量
1
作者 郭凤莲 《华夏医学》 1998年第2期39-40,共2页
采用双波分光光度法测定伤风止咳冲剂中盐酸异丙嗪的含量,不需预先分离即可直接测定,方法简便可靠,平均回收率及相对标准偏差为99.57%、1.2%。
关键词 伤风止咳冲剂 盐酸异丙嗪 双波分光光度法测定
全文增补中
铬黑T双波长分光光度法测定水中的镁 被引量:4
2
作者 张丽萍 张昆蓉 《应用科技》 CAS 2001年第6期45-46,共2页
研究了以铬黑T为显色剂 ,双波长分光光度法测定水中的镁含量的方法 ,检验了方法的精密度及准确度 。
关键词 铬黑T 双波分光光度法 水测定
在线阅读 下载PDF
ISOSBESTIC DUAL WAVELENGTH SPEOTROPHOTOMETRIC SIMULTANEOUS DETERMINATION OF ZINC AND OADMIUM USING meso-TETRAKIS[4-(TRIMETHYLAMMONIUM) PHENYL] PORPHINE
3
作者 肖新亮 张淑芬 +2 位作者 刘瑞贤 沈含熙 杨俊佼 《Transactions of Tianjin University》 EI CAS 1995年第2期118+115-118,共5页
Iin this paper an isosbestic dual--wavelength spectrophotometric method for the simultaneous determination of zinc and cadmium using meso--tetrakis [4-(trimethylammonium) phenyl] porphine has been developed. The inter... Iin this paper an isosbestic dual--wavelength spectrophotometric method for the simultaneous determination of zinc and cadmium using meso--tetrakis [4-(trimethylammonium) phenyl] porphine has been developed. The interference from excess of reagent was masked by adding lead ions solution.The molar absorptivities (Ae) for zinc and cadmium were 6. 54 × 105 and 4. 27 × 105 L. mol-1. cm-1,respectively. The method could be used to determine zinc and cadmium in synthetic mixtures, and the satisfied results were obtained. 展开更多
关键词 dual-wavelength spectrophotometry zinc and cadmium determination meso--tetrakis [4(trimethylammonium) phenyl] porphine
在线阅读 下载PDF
A Dual Wavelength Differential First Derivative Spectrophotometric Method for Identification and Determination of Carbon Monoxide Generated During the Microsomal Metabolism of Xenobiotics in vitro
4
作者 徐宏祥 刘志强 《Journal of Chinese Pharmaceutical Sciences》 CAS 1997年第2期51-56,共6页
A dual wavelength differential first derivative spectrophotometric method has been developed to standardize the concentration of a saturated aqueous solution of carbon monoxide (CO) as the standard and to identify and... A dual wavelength differential first derivative spectrophotometric method has been developed to standardize the concentration of a saturated aqueous solution of carbon monoxide (CO) as the standard and to identify and to determine CO formed during the microsomal metabolism of xenobiotics in vitro. The method can significantly eliminate the background interference in the assay media and increase the quantitative accuracy and the sensitivity. There is a good linear relationship between CO concentration in the range of 2~10 μmol·L 1 CO and the distance D between the first derivative peak at 415 nm amd valley at 426 nm with r=0.9999(n=5),the regression equation being C (mmol·L 1 )=17.6D 0.4, the detection limit lower than 0.1 μmol·L 1 CO. The average recoveries of CO from the assay system and the sample were 102.1%, RSD=2.9% (n=7) and 79.7%, RSD=6.8% (n=12),respectively. The RSD of within day was 4.4%(n=18),and the RSD of day to day was 6.1%(n=16). By this method, four trihaloanilines and one trihalobenzene were tested, the results showed that only 2,4,5 trifluoroaniline could be converted to CO by the incubation with rat hepatic microsomes, NADPH and oxygen, the ability of phenobarbital or dexamethasone to induce rat hepatic microsomes to catalyze CO formation was 3 or 8 times higher than that of the control. 展开更多
关键词 Dual wavelength differential first derivative spectrophotometry Carbon monoxide Trifluoroaniline Drug metabolism Hepatic microsomes Cytochrome P 450
全文增补中
Determination of Cholesterol Content in Waste Fat by Dual-wavelength Spectrophotometry
5
作者 LIU Jia-di XU Shu-jun +1 位作者 XU Chun-xiang QIN Jin-ping 《Chinese Food Science》 2012年第2期40-42,共3页
[Objective]The aim was to find a way to measure the cholesterol content in deserted oil.[Method]Dual-wavelength spectrophotometry method was used for the determination of cholesterol in edible oil.630 nm and 720 nm we... [Objective]The aim was to find a way to measure the cholesterol content in deserted oil.[Method]Dual-wavelength spectrophotometry method was used for the determination of cholesterol in edible oil.630 nm and 720 nm were set as target band and reference band in this method,respectively.The result was compared to liquid chromatography method.[Result]The relative standard deviation(RSD)was at 1.26% and recovery was between 101.9% and 110.7%.Linear range was 8.0-40.0 μg/ml.The tested result was close to the result of liquid chromatography.[Conclusion]It was proved that this method was easy,fast and accurate.The disturbance of sitosterol was eliminated without isolation.It can be used for fast identification of the authenticity of waste fat. 展开更多
关键词 Dual-wavelength Spectrophotometry Waste fat CHOLESTEROL SITOSTEROL China
在线阅读 下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部