期刊文献+
共找到4篇文章
< 1 >
每页显示 20 50 100
一种基于参数提取算法的快速ADC测试方法 被引量:3
1
作者 陈豹 王逢州 《电子器件》 CAS 北大核心 2017年第5期1145-1150,共6页
对于传统的ADC测试方法,若要得到动、静态性能指标,需通过两次测试测得,所需时间较长。文章首先采用移动平均滤波器对静态测试时的直方图算法进行时间优化,然后对静态测试采集的测试点进行抽取,并消除增益误差后,基于参数提取算法通过... 对于传统的ADC测试方法,若要得到动、静态性能指标,需通过两次测试测得,所需时间较长。文章首先采用移动平均滤波器对静态测试时的直方图算法进行时间优化,然后对静态测试采集的测试点进行抽取,并消除增益误差后,基于参数提取算法通过傅里叶变化得到所有的ADC动态参数。实验结果表明,文章所提算法所得的最大INL估算误差为0.186 LSB,SINAD、ENOB、THD、SFDR估算误差分别为0.211 d B、0.035、0.159 d B、0.119 d B。与原估算算法相比,优化算法所得SINAD和ENOB的估算精度提高了0.411 d B和0.057。与传统ADC测试方法相比,在保证测试精度的前提下,测试时间减少了50.769%。 展开更多
关键词 ADC测试 测试估算 参数提取 移动平均滤波
在线阅读 下载PDF
Influence of age in estimating maximal oxygen uptake 被引量:2
2
作者 Christina G de Souza Silva Barry A Franklin +1 位作者 Daniel E Forman Claudio Gil S Araujo 《Journal of Geriatric Cardiology》 SCIE CAS CSCD 2016年第2期126-131,共6页
Objective To assess the influence of age on the error of estimate (EE) of maximal oxygen uptake (VO2max) using sex and population specific-equations in cycle ergometer exercise testing, since estimated VO2 max is ... Objective To assess the influence of age on the error of estimate (EE) of maximal oxygen uptake (VO2max) using sex and population specific-equations in cycle ergometer exercise testing, since estimated VO2 max is associated with a substantial EE, often exceeding 20%, possibly due to intrinsic variability of mechanical efficiency. Methods 1850 adults (68% men), aged 18 to 91 years, underwent maximal cycle ergometer cardiopulmonary exercise testing. Cardiorespiratory fitness (CRF) was assessed relative to sex and age [younger (18 to 35 years), middle-aged (36 to 60 years) and older (〉 60 years)]. VO2max [mL.(kg.min)-1] was directly measured by assessment of gas exchange and estimated using sex and population specific-equations. Measured and estimated values of VO2max and related EE were compared among the three age- and sex-specific groups. Results Directly measured VO2max of men and women were 29.5 ± 10.5 mL.(kg.min)-1 and 24.2 ± 9.0 mL.(kg·min) -1 (P 〈 0.01). EE [mL·(kg·min)-1] and percent errors (%E) for men and women had similar values, 0.5 ± 3.2 and 0.4 ± 2.9 mL·(kg·min)-1, and -0.8 ± 13.1% and -1.7 ± 15.4% (P 〉 0.05), respectively. EE and %E for each age-group were, respectively, for men: younger = 1.9 ± 4.1 mL·(kg·min)-1 and 3.8 ± 10.5%, middle-aged = 0.6 ± 3.1 mL.(kg·min)-1 and 0.4 ± 10.3%, older = -0.2 ± 2.7 mL·(kg·min) -1 and -4.2 ± 16.6% (P 〈 0.01); and for women: younger = 1.2 ± 3.1 mL.(kg.min)-1 and 2.7 ±10.0%, middle-aged = 0.7 ± 2.8 mL·(kg·min)-1 and 0.5 ± 11.1%, older = -0.8 ± 2.3 mL-(kg·min)-1 and -9.5 ± 22.4% (P 〈 0.01). Conclusion VO2max were underestimated in younger age-groups and were overestimated in older age groups. Age significantly influences the magnitude of the EE of VO2max in both men and women and should be considered when CRF is estimated using population specific equations, rather than directly measured. 展开更多
关键词 AGING Cardiopulmonary exercise testing Error of measurement
在线阅读 下载PDF
Main Gas Pipelines: Fracture Resistance Assessment of Pipes 被引量:1
3
作者 Aleksander Mitin 《Journal of Mechanics Engineering and Automation》 2013年第3期127-140,共14页
This paper proposes an estimation method of fracture resistance of oil & gas pipes, based on the results of full scale hydraulic pressure pipe testing with the artificial notch, made by the authors at 2002-2006. It s... This paper proposes an estimation method of fracture resistance of oil & gas pipes, based on the results of full scale hydraulic pressure pipe testing with the artificial notch, made by the authors at 2002-2006. It shows that the fracture process at the stage of stripping (initialization) of crack can be characterized by Critical Fracture Diagram (CFD). Calculating and experimental way to construct CFD is suggested and discussed. The fracture resistance requirements for oil & gas pipes in terms of fracture mechanics (Kc, Lc) are formulated and proved. The results of full scale hydraulic pressure pipe testing, based on metal testing data of the standard Charpy specimens (KCV) and pipe's specification requirements are interrelated. The way to estimate the admissible temperature operation conditions of oil & gas pipes by means of based metal "KCV-temperature" dependence is proposed. 展开更多
关键词 Critical fracture diagram (CFD) hydraulic pipe testing stress intensity factor main gas pipeline.
在线阅读 下载PDF
A study of laboratory testing and calculation methods for coal sorption isotherms
4
作者 Lei ZHANG Ting-Xiang REN Nai AZIZ 《Journal of Coal Science & Engineering(China)》 2013年第2期193-202,共10页
Measurement of the volume of gas adsorbed per unit mass of coal with increasing pressure at a constant temperature produces an isotherm that describes the gas storage capacity of this type of coal. The accurate testin... Measurement of the volume of gas adsorbed per unit mass of coal with increasing pressure at a constant temperature produces an isotherm that describes the gas storage capacity of this type of coal. The accurate testing and interpretation of coal sorption isotherm plays an important role in the areas of coal mine methane drainage, coalbed methane (CBM) reservoir resource assessment, enhanced coalbed methane (ECBM) recovery, as well as the carbon dioxide (CO2) sequestration in deep coal seams or similar geological formations. Different coal sorption isotherm testing apparatus and associated calculation methods are critically reviewed and presented in this paper. These include both volumetric and gravimetric based methods, as well as experimental sorption tests with confining stress and direction sorption methods. The volumetric techniques utilise experimental apparatus with sample cell and injection pump and that with both sample cell and reference cell. Whilst the gravimetric approachesinclude methods with sample cell and suspension magnetic balance and that with both sample cell and reference cell. Different testing methods are compared and discussed in this study. A unique in-house-built coal sorption isotherm testing apparatus at the University of Wollongong was presented together with the calculation method, procedures and experimental results. The isotherm results can be calculated by both Soave-Redlich-Kwong (SRK) equation and calibration cure methods which can be used directly to convert the volume of adsorbed gas in different test conditions to standard condition (NTP). 展开更多
关键词 sorption isotherm coalbed methane coal mine gas apparatus calculation method volumetric method gravimetric method
在线阅读 下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部