In designing the human comfort index (CI) used in Guangzhou, a Gaussian curve was adopted as the fundamental profile to develop a traw hat?model of comfort index. The model projects low or high temperatures into low i...In designing the human comfort index (CI) used in Guangzhou, a Gaussian curve was adopted as the fundamental profile to develop a traw hat?model of comfort index. The model projects low or high temperatures into low index values and the moderate temperatures into high index values. Air temperature was chosen as a basic factor in the model. Other factors such as humidity, sunshine and wind speed were introduced by considering them as temperature departures to an equivalent apparent temperature (EAT). Since the index is a relative index, 25C was chosen as an ideal apparent temperature (the most comfortable state) and a maximum CI value of 100 was assigned at this temperature. While in other circumstances, the index would be lower than 100. By utilizing this model, the daily comfort index values had been calculated for Guangzhou city for 1998-1999, using mean temperature, mean humidity, mean wind speed and total hours of sunshine. Results show that the new model was reasonable and practicable. Not only could it reflect the monthly variation of human comfort in Guangzhou, but also was sensitive to short-term changes of weather conditions.展开更多
Latvian children under the age of 7 can spend up to 60 hours per week in daycare centers and therefore it is very important to establish a healthy and comfortable daycare environment that children will find pleasant a...Latvian children under the age of 7 can spend up to 60 hours per week in daycare centers and therefore it is very important to establish a healthy and comfortable daycare environment that children will find pleasant and stimulating to stay in. This study investigates indoor air quality and thermal comfort within six daycare centers (old, renovated and new-built) in moderate climate zone of Latvia. Measurements of carbon dioxide, air temperature and relative humidity were carried out, and data regarding daycare center characteristics and maintenance activities was collected via combination of field visits, record analysis and interviews. It was found that carbon dioxide concentrations exceeded 1000 ppm in 75% of daycare centers studied, with the highest (1356 ppm) measured in a renovated facility with the natural ventilation system. Thus installation of more efficient ventilation system (mechanical) is recommended to provide acceptable indoor air quality, since opening of windows itself cannot provide the optimal conditions indoors. In all facilities the temperature was kept above 20℃ and the average relative humidity was 40±35%, creating comfortable thermal environment for children.展开更多
文摘In designing the human comfort index (CI) used in Guangzhou, a Gaussian curve was adopted as the fundamental profile to develop a traw hat?model of comfort index. The model projects low or high temperatures into low index values and the moderate temperatures into high index values. Air temperature was chosen as a basic factor in the model. Other factors such as humidity, sunshine and wind speed were introduced by considering them as temperature departures to an equivalent apparent temperature (EAT). Since the index is a relative index, 25C was chosen as an ideal apparent temperature (the most comfortable state) and a maximum CI value of 100 was assigned at this temperature. While in other circumstances, the index would be lower than 100. By utilizing this model, the daily comfort index values had been calculated for Guangzhou city for 1998-1999, using mean temperature, mean humidity, mean wind speed and total hours of sunshine. Results show that the new model was reasonable and practicable. Not only could it reflect the monthly variation of human comfort in Guangzhou, but also was sensitive to short-term changes of weather conditions.
文摘Latvian children under the age of 7 can spend up to 60 hours per week in daycare centers and therefore it is very important to establish a healthy and comfortable daycare environment that children will find pleasant and stimulating to stay in. This study investigates indoor air quality and thermal comfort within six daycare centers (old, renovated and new-built) in moderate climate zone of Latvia. Measurements of carbon dioxide, air temperature and relative humidity were carried out, and data regarding daycare center characteristics and maintenance activities was collected via combination of field visits, record analysis and interviews. It was found that carbon dioxide concentrations exceeded 1000 ppm in 75% of daycare centers studied, with the highest (1356 ppm) measured in a renovated facility with the natural ventilation system. Thus installation of more efficient ventilation system (mechanical) is recommended to provide acceptable indoor air quality, since opening of windows itself cannot provide the optimal conditions indoors. In all facilities the temperature was kept above 20℃ and the average relative humidity was 40±35%, creating comfortable thermal environment for children.