期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
装配式住宅预制夹芯保温复合外墙内部冷凝问题研究 被引量:5
1
作者 管文 赵立群 《混凝土与水泥制品》 北大核心 2012年第8期50-52,共3页
分别以泡沫混凝土保温板和改性酚醛保温板作为预制夹芯保温复合外墙的夹芯保温层材料,对夹芯保温复合外墙的内部冷凝问题进行了理论计算,结果表明,在夏热冬冷地区墙体构造为60mm钢筋混凝土+70mm泡沫混凝土+60mm钢筋混凝土的夹芯保温复... 分别以泡沫混凝土保温板和改性酚醛保温板作为预制夹芯保温复合外墙的夹芯保温层材料,对夹芯保温复合外墙的内部冷凝问题进行了理论计算,结果表明,在夏热冬冷地区墙体构造为60mm钢筋混凝土+70mm泡沫混凝土+60mm钢筋混凝土的夹芯保温复合外墙内部存在冷凝问题,但泡沫混凝土保温层因内部冷凝受潮而增加的湿度增量在允许范围之内,所产生的冷凝水数量不会对结构造成损害;而墙体构造为60mm钢筋混凝土+40mm改性酚醛保温板+60mm钢筋混凝土的夹芯保温复合外墙内部则不存在冷凝问题。 展开更多
关键词 装配式住宅 预制夹芯保温复合墙体 泡沫混凝土保温 改性酚醛保温 冷凝验算
在线阅读 下载PDF
Experimental study on axial compressive behaviors of prefabricated composite thermal insulation walls after single-side fire exposure
2
作者 Fu Qian Zhu Xiaojun +4 位作者 Liang Shuting Yang Jian Li Xiangmin Xu Qingfeng Gao Mingzhu 《Journal of Southeast University(English Edition)》 EI CAS 2018年第2期220-228,共9页
The axial bearing capacity of prefabricated composite walls composed of inner and outer concrete wythes,expandable polystyrene(EPS)boards and steel sleeve connectors is investigated.An experimental study on the axial ... The axial bearing capacity of prefabricated composite walls composed of inner and outer concrete wythes,expandable polystyrene(EPS)boards and steel sleeve connectors is investigated.An experimental study on the axial bearing capacity of four prefabricated composite walls after fire treatment is carried out.Two of the prefabricated composite walls are normal-temperature specimens,and the others are treated with fire.The damage modes and crack development are observed,and the axial bearing capacity,lateral deformation of the specimens,and the concrete and reinforcing bar strain are tested.The results show that the ultimate bearing capacity of specimens after a fire is less than that of normal-temperature specimens;when the insulation board thicknesses are 40 mm and 60 mm,the decrease amplitudes are 20.8%and 16.8%,respectively.The maximum lateral deformation of specimens after a fire is greater than that of normal-temperature specimens,and under the same level of load,the lateral deformation increases as the insulation board thickness increases.Moreover,the strain values of the concrete and reinforcing bars of specimens after a fire are greater than those of normal-temperature specimens,and the strain values increase as the thickness of insulation board increases. 展开更多
关键词 prefabricated composite thermal insulation walls expandable polystyrene board fire exposure insulation layer post-re axial compressive behavior
在线阅读 下载PDF
上一页 1 下一页 到第