BACKGROUND Anxiety is a common comorbidity in patients with Crohn’s disease(CD).Data on the imaging characteristics of brain microstructure and cerebral perfusion in CD with anxiety are limited.AIM To compare the ima...BACKGROUND Anxiety is a common comorbidity in patients with Crohn’s disease(CD).Data on the imaging characteristics of brain microstructure and cerebral perfusion in CD with anxiety are limited.AIM To compare the imaging characteristics of brain microstructure and cerebral perfusion among CD patients with or without anxiety and healthy individuals.METHODS This prospective comparative study enrolled consecutive patients with active CD and healthy individuals who visited the study hospital between January 2022 and January 2023.Anxiety was measured using the Hospital Anxiety and Depression Scale-Anxiety.The imaging characteristics of brain microstructure and cerebral perfusion were measured by diffusion kurtosis imaging and intravoxel incoherent motion.RESULTSA total of 57 participants were enrolled. Among the patients with active CD, 16 had anxiety. Compared withhealthy individuals, patients with active CD demonstrated significantly lower radial kurtosis values in the rightcerebellar region 6, lower axial kurtosis (AK) values in the right insula, left superior temporal gyrus, and rightthalamus, and higher slow and fast apparent diffusion coefficients (ADCslow and ADCfast) in the bilateral frontal lobe,bilateral temporal lobe, and bilateral insular lobe (all P < 0.05). Compared with patients with CD without anxiety,patients with CD and anxiety exhibited significantly higher ADCslow values in the left insular lobe and lower AKvalues in the right insula and right anterior cuneus (all P < 0.05).CONCLUSIONThere are variations in brain microstructure and perfusion among CD patients with/without anxiety and healthyindividuals, suggesting potential use in assessing anxiety-related changes in active CD.展开更多
Objective:This study focused on the clinical application value of dynamic CT perfusion imaging in stroke.Methods:A total of 92 patients with stroke were enrolled in this study.All patients were selected from December ...Objective:This study focused on the clinical application value of dynamic CT perfusion imaging in stroke.Methods:A total of 92 patients with stroke were enrolled in this study.All patients were selected from December 2017 to December 2018 according to different diagnostic methods.They were randomly divided into two groups:the observation group and control group.The number of patients in each group was 46.The observation group mainly used dynamic CT perfusion imaging for diagnosis while the control group mainly used CT plain scan.The diagnostic effects of the two groups of patients and the hemodynamic parameters of the surrounding area of sub-acute hematoma and the acute phase of stroke in the observation group were compared.Results:The clinical diagnosis of the observation group was 95.65%while the clinical diagnosis of the control group was 69.57%.The observation group was higher than that of the control group and the difference was significant.In addition,the hemodynamic parameters of the acute phase of the observation group and the sub-acute hematoma were also varied.Conclusion:Dynamic CT perfusion imaging has significant clinical value in stroke,and it is worthy of further application.展开更多
Summary: To study the dynamic changes of CT perfusion parameters during the first 12 h in the embolic cerebral ischemia models. Local cerebral ischemia model were established in 7 New Zealand white rabbits. All CT sca...Summary: To study the dynamic changes of CT perfusion parameters during the first 12 h in the embolic cerebral ischemia models. Local cerebral ischemia model were established in 7 New Zealand white rabbits. All CT scans were performed with a GE Lightspeed 16 multislice CT. Following the baseline scan, further CT perfusion scans were performed at the same locations 20 min, 1-6 h and 8, 10 and 12 h after the embolus delivery. Maps of all parameters were obtained by CT perfusion software at each time point. The brains, taken 12 h after the scan, were sliced corresponding to the positions of the CT slices and stained by 2,3,5-triphenyltetrazolium chloride (TTC). On the basis of the TTC results, the ischemic sides were divided into 3 regions: core, penumbra and the relatively normal region. The changes of all parameters were then divided into 3 stages. In the first two hours (the first stage), the CBV dropped more remarkably in the core than in the penumbra but rose slightly in the relatively normal region while the CBF decreased and MTT, TTP extended in all regions to varying degrees. In the 2nd-5th h (the second stage), all the parameters fluctuated slightly around a certain level. In the 5th-12th h (the third stage), the CBV and CBF dropped, and MTT and TTP were prolonged or shortened slightly in the core and penumbra though much notably in the former while the CBV, CBF rose and MTT, TTP were shortened remarkably in the relatively normal region. We experimentally demonstrated that the location and extent of cerebral ischemia could be accurately assessed by CT perfusion imaging. The pathophysiology of the ischemia could be reflected by the CT perfusion to varying degrees.展开更多
Imaging technologies are utilized to study the brain morphology and the functions of rat models of Parkinson disease (PD). Magnetic resonance imaging (MRI) and magnetic resonance angiography (MRA) are used to ob...Imaging technologies are utilized to study the brain morphology and the functions of rat models of Parkinson disease (PD). Magnetic resonance imaging (MRI) and magnetic resonance angiography (MRA) are used to obtain morphological imaging data. Functional imaging data, such as the spectrum and blood flow changes are obtained by proton magnetic resonance spectroscopy (1H-MRS) and CT perfusion (CTP). Results show that PD rat models have no characteristic morphological imaging abnormalities, but exist regional cerebral blood flow (CBF) reductions and spectral changes in the striatum.展开更多
Thirty-four patients with cerebral infarction and 18 patients with transient ischemic attack were examined by multi-slice spiral CT scan, CT perfusion imaging, and CT angiography within 6 hours after onset. By CT perf...Thirty-four patients with cerebral infarction and 18 patients with transient ischemic attack were examined by multi-slice spiral CT scan, CT perfusion imaging, and CT angiography within 6 hours after onset. By CT perfusion imaging, 29 cases in the cerebral infarction group and 10 cases in the transient ischemic attack group presented with abnormal blood flow perfusion, which corresponded to the clinical symptoms. By CT angiography, various degrees of vascular stenosis could be detected in 41 patients, including 33 in the cerebral infarction group and eight in the transient ischemic attack group. The incidence of intracranial artery stenosis was higher than that of extracranial artery stenosis. The intracranial artery stenosis was located predominantly in the middle cerebral artery and carotid artery siphon, while the extracranial artery stenosis occurred mainly in the bifurcation of the common carotid artery and the opening of the vertebral artery. There were 34 cases (83%) with convict vascular stenosis and perfusion abnormalities, and five cases (45%) with perfusion abnormalities but without convict vascular stenosis. The incidence of cerebral infarction in patients with National Institutes of Health Stroke Scale scores 〉 5 points during onset was significantly higher than that in patients with National Institutes of Health Stroke Scale scores 〈 5 points. These experimental findings indicate that the combined application of various CT imaging methods allows early diagnosis of acute ischemic cerebrovascular disease, which can comprehensively analyze the pathogenesis and severity of acute ischemic cerebrovascular disease at the morphological and functional levels.展开更多
目的:分析Brain Time Stack图像融合技术在CT中的应用。方法:选取2021年3月—2022年9月衡水市第四人民医院收治的50例CT检查患者作为研究对象。所有患者进行CT检查并进行Brain Time Stack后处理。比较四组不同部位CT值、标准差(SD)、信...目的:分析Brain Time Stack图像融合技术在CT中的应用。方法:选取2021年3月—2022年9月衡水市第四人民医院收治的50例CT检查患者作为研究对象。所有患者进行CT检查并进行Brain Time Stack后处理。比较四组不同部位CT值、标准差(SD)、信噪比(SNR)。比较四组图像主观质量评分。分析不同部位CT值、SD、SNR与图像主观质量评分的相关性。结果:B组的延髓、额叶灰质、额叶白质、小脑内侧、小脑外侧、颞肌肌肉CT值明显低于A组;C组的延髓、脑室、额叶白质、小脑内侧、小脑外侧、颞肌肌肉CT值高于A组;D组延髓、额叶灰质、颞肌肌肉CT值明显低于A组,脑室、额叶白质、小脑外侧CT值明显高于A组;C组延髓、额叶灰质、额叶白质、小脑内侧、小脑外侧、颞肌肌肉CT值明显高于B组;D组延髓、脑室、额叶白质、小脑内侧、小脑外侧、颞肌肌肉CT值明显高于B组;D组延髓、额叶灰质、额叶白质、小脑内侧、小脑外侧、颞肌肌肉CT值明显低于C组;D组脑室CT值明显高于C组,差异有统计学意义(P<0.05)。B组、C组、D组延髓、脑室、额叶灰质、额叶白质、小脑内侧、小脑外侧、颞肌肌肉SD值明显低于A组;C组延髓、脑室、额叶白质、小脑内侧、小脑外侧、颞肌肌肉SD值均明显高于B组;C组额叶灰质SD明显低于B组;D组延髓、脑室、额叶灰质、额叶白质、小脑内侧、小脑外侧、肌肉SD均明显低于B组、C组,差异有统计学意义(P<0.05)。B组、C组、D组延髓、脑室、额叶灰质、额叶白质、小脑内侧、小脑外侧、颞肌肌肉SNR均明显高于A组;C组、D组延髓、额叶灰质、额叶白质、小脑内侧、小脑外侧、颞肌肌肉SNR值明显高于B组;C组、D组脑室SNR明显低于B组;D组延髓、脑室、额叶灰质、额叶白质、小脑内侧、小脑外侧、颞肌肌肉SNR明显高于C组,差异有统计学意义(P<0.05)。D组图像主观质量评分最高,差异有统计学意义(P<0.05)。延髓、脑室、额叶灰质、额叶白质、小脑内侧、小脑外侧及颞肌肌肉SD与主观质量评分呈明显负相关,SNR与主观质量评分间呈明显正相关,差异有统计学意义(P<0.05)。结论:利用Brain Time Stack图像融合技术对头部CT扫描检查图像处理,动脉期结合前一期及后一期的图像数据在处理后具有更好的质量和更少的噪音。展开更多
Cerebral perfusion computed tomography(PCT)is an important imaging modality for evaluating cerebrovascular diseases and stroke symptoms.With widespread public concern about the potential cancer risks and health hazard...Cerebral perfusion computed tomography(PCT)is an important imaging modality for evaluating cerebrovascular diseases and stroke symptoms.With widespread public concern about the potential cancer risks and health hazards associated with cumulative radiation exposure in PCT imaging,considerable research has been conducted to reduce the radiation dose in X-ray-based brain perfusion imaging.Reducing the dose of X-rays causes severe noise and artifacts in PCT images.To solve this problem,we propose a deep learning method called NCS-Unet.The exceptional characteristics of non-subsampled contourlet transform(NSCT)and the Sobel filter are introduced into NCS-Unet.NSCT decomposes the convolved features into high-and low-frequency components.The decomposed high-frequency component retains image edges,contrast imaging traces,and noise,whereas the low-frequency component retains the main image information.The Sobel filter extracts the contours of the original image and the imaging traces caused by the contrast agent decay.The extracted information is added to NCS-Unet to improve its performance in noise reduction and artifact removal.Qualitative and quantitative analyses demonstrated that the proposed NCS-Unet can improve the quality of low-dose cone-beam CT perfusion reconstruction images and the accuracy of perfusion parameter calculations.展开更多
In order to effectively improve the pathological diagnosis capability and feature resolution of 3D human brain CT images,a threshold segmentation method of multi-resolution 3D human brain CT image based on edge pixel ...In order to effectively improve the pathological diagnosis capability and feature resolution of 3D human brain CT images,a threshold segmentation method of multi-resolution 3D human brain CT image based on edge pixel grayscale feature decomposition is proposed in this paper.In this method,first,original 3D human brain image information is collected,and CT image filtering is performed to the collected information through the gradient value decomposition method,and edge contour features of the 3D human brain CT image are extracted.Then,the threshold segmentation method is adopted to segment the regional pixel feature block of the 3D human brain CT image to segment the image into block vectors with high-resolution feature points,and the 3D human brain CT image is reconstructed with the salient feature point as center.Simulation results show that the method proposed in this paper can provide accuracy up to 100%when the signal-to-noise ratio is 0,and with the increase of signal-to-noise ratio,the accuracy provided by this method is stable at 100%.Comparison results show that the threshold segmentation method of multi-resolution 3D human brain CT image based on edge pixel grayscale feature decomposition is signicantly better than traditional methods in pathological feature estimation accuracy,and it effectively improves the rapid pathological diagnosis and positioning recognition abilities to CT images.展开更多
基金Ethics Committee of Affiliated Changzhou Second People’s Hospital of Nanjing Medical University(approval number KY039-01).
文摘BACKGROUND Anxiety is a common comorbidity in patients with Crohn’s disease(CD).Data on the imaging characteristics of brain microstructure and cerebral perfusion in CD with anxiety are limited.AIM To compare the imaging characteristics of brain microstructure and cerebral perfusion among CD patients with or without anxiety and healthy individuals.METHODS This prospective comparative study enrolled consecutive patients with active CD and healthy individuals who visited the study hospital between January 2022 and January 2023.Anxiety was measured using the Hospital Anxiety and Depression Scale-Anxiety.The imaging characteristics of brain microstructure and cerebral perfusion were measured by diffusion kurtosis imaging and intravoxel incoherent motion.RESULTSA total of 57 participants were enrolled. Among the patients with active CD, 16 had anxiety. Compared withhealthy individuals, patients with active CD demonstrated significantly lower radial kurtosis values in the rightcerebellar region 6, lower axial kurtosis (AK) values in the right insula, left superior temporal gyrus, and rightthalamus, and higher slow and fast apparent diffusion coefficients (ADCslow and ADCfast) in the bilateral frontal lobe,bilateral temporal lobe, and bilateral insular lobe (all P < 0.05). Compared with patients with CD without anxiety,patients with CD and anxiety exhibited significantly higher ADCslow values in the left insular lobe and lower AKvalues in the right insula and right anterior cuneus (all P < 0.05).CONCLUSIONThere are variations in brain microstructure and perfusion among CD patients with/without anxiety and healthyindividuals, suggesting potential use in assessing anxiety-related changes in active CD.
文摘Objective:This study focused on the clinical application value of dynamic CT perfusion imaging in stroke.Methods:A total of 92 patients with stroke were enrolled in this study.All patients were selected from December 2017 to December 2018 according to different diagnostic methods.They were randomly divided into two groups:the observation group and control group.The number of patients in each group was 46.The observation group mainly used dynamic CT perfusion imaging for diagnosis while the control group mainly used CT plain scan.The diagnostic effects of the two groups of patients and the hemodynamic parameters of the surrounding area of sub-acute hematoma and the acute phase of stroke in the observation group were compared.Results:The clinical diagnosis of the observation group was 95.65%while the clinical diagnosis of the control group was 69.57%.The observation group was higher than that of the control group and the difference was significant.In addition,the hemodynamic parameters of the acute phase of the observation group and the sub-acute hematoma were also varied.Conclusion:Dynamic CT perfusion imaging has significant clinical value in stroke,and it is worthy of further application.
文摘Summary: To study the dynamic changes of CT perfusion parameters during the first 12 h in the embolic cerebral ischemia models. Local cerebral ischemia model were established in 7 New Zealand white rabbits. All CT scans were performed with a GE Lightspeed 16 multislice CT. Following the baseline scan, further CT perfusion scans were performed at the same locations 20 min, 1-6 h and 8, 10 and 12 h after the embolus delivery. Maps of all parameters were obtained by CT perfusion software at each time point. The brains, taken 12 h after the scan, were sliced corresponding to the positions of the CT slices and stained by 2,3,5-triphenyltetrazolium chloride (TTC). On the basis of the TTC results, the ischemic sides were divided into 3 regions: core, penumbra and the relatively normal region. The changes of all parameters were then divided into 3 stages. In the first two hours (the first stage), the CBV dropped more remarkably in the core than in the penumbra but rose slightly in the relatively normal region while the CBF decreased and MTT, TTP extended in all regions to varying degrees. In the 2nd-5th h (the second stage), all the parameters fluctuated slightly around a certain level. In the 5th-12th h (the third stage), the CBV and CBF dropped, and MTT and TTP were prolonged or shortened slightly in the core and penumbra though much notably in the former while the CBV, CBF rose and MTT, TTP were shortened remarkably in the relatively normal region. We experimentally demonstrated that the location and extent of cerebral ischemia could be accurately assessed by CT perfusion imaging. The pathophysiology of the ischemia could be reflected by the CT perfusion to varying degrees.
基金Supported by the National Natural Science Foundation of China (30671997)~~
文摘Imaging technologies are utilized to study the brain morphology and the functions of rat models of Parkinson disease (PD). Magnetic resonance imaging (MRI) and magnetic resonance angiography (MRA) are used to obtain morphological imaging data. Functional imaging data, such as the spectrum and blood flow changes are obtained by proton magnetic resonance spectroscopy (1H-MRS) and CT perfusion (CTP). Results show that PD rat models have no characteristic morphological imaging abnormalities, but exist regional cerebral blood flow (CBF) reductions and spectral changes in the striatum.
基金supported by the Youth Fund of the First Clinical College of Liaoning Medical University, No. 2010C20
文摘Thirty-four patients with cerebral infarction and 18 patients with transient ischemic attack were examined by multi-slice spiral CT scan, CT perfusion imaging, and CT angiography within 6 hours after onset. By CT perfusion imaging, 29 cases in the cerebral infarction group and 10 cases in the transient ischemic attack group presented with abnormal blood flow perfusion, which corresponded to the clinical symptoms. By CT angiography, various degrees of vascular stenosis could be detected in 41 patients, including 33 in the cerebral infarction group and eight in the transient ischemic attack group. The incidence of intracranial artery stenosis was higher than that of extracranial artery stenosis. The intracranial artery stenosis was located predominantly in the middle cerebral artery and carotid artery siphon, while the extracranial artery stenosis occurred mainly in the bifurcation of the common carotid artery and the opening of the vertebral artery. There were 34 cases (83%) with convict vascular stenosis and perfusion abnormalities, and five cases (45%) with perfusion abnormalities but without convict vascular stenosis. The incidence of cerebral infarction in patients with National Institutes of Health Stroke Scale scores 〉 5 points during onset was significantly higher than that in patients with National Institutes of Health Stroke Scale scores 〈 5 points. These experimental findings indicate that the combined application of various CT imaging methods allows early diagnosis of acute ischemic cerebrovascular disease, which can comprehensively analyze the pathogenesis and severity of acute ischemic cerebrovascular disease at the morphological and functional levels.
文摘目的:分析Brain Time Stack图像融合技术在CT中的应用。方法:选取2021年3月—2022年9月衡水市第四人民医院收治的50例CT检查患者作为研究对象。所有患者进行CT检查并进行Brain Time Stack后处理。比较四组不同部位CT值、标准差(SD)、信噪比(SNR)。比较四组图像主观质量评分。分析不同部位CT值、SD、SNR与图像主观质量评分的相关性。结果:B组的延髓、额叶灰质、额叶白质、小脑内侧、小脑外侧、颞肌肌肉CT值明显低于A组;C组的延髓、脑室、额叶白质、小脑内侧、小脑外侧、颞肌肌肉CT值高于A组;D组延髓、额叶灰质、颞肌肌肉CT值明显低于A组,脑室、额叶白质、小脑外侧CT值明显高于A组;C组延髓、额叶灰质、额叶白质、小脑内侧、小脑外侧、颞肌肌肉CT值明显高于B组;D组延髓、脑室、额叶白质、小脑内侧、小脑外侧、颞肌肌肉CT值明显高于B组;D组延髓、额叶灰质、额叶白质、小脑内侧、小脑外侧、颞肌肌肉CT值明显低于C组;D组脑室CT值明显高于C组,差异有统计学意义(P<0.05)。B组、C组、D组延髓、脑室、额叶灰质、额叶白质、小脑内侧、小脑外侧、颞肌肌肉SD值明显低于A组;C组延髓、脑室、额叶白质、小脑内侧、小脑外侧、颞肌肌肉SD值均明显高于B组;C组额叶灰质SD明显低于B组;D组延髓、脑室、额叶灰质、额叶白质、小脑内侧、小脑外侧、肌肉SD均明显低于B组、C组,差异有统计学意义(P<0.05)。B组、C组、D组延髓、脑室、额叶灰质、额叶白质、小脑内侧、小脑外侧、颞肌肌肉SNR均明显高于A组;C组、D组延髓、额叶灰质、额叶白质、小脑内侧、小脑外侧、颞肌肌肉SNR值明显高于B组;C组、D组脑室SNR明显低于B组;D组延髓、脑室、额叶灰质、额叶白质、小脑内侧、小脑外侧、颞肌肌肉SNR明显高于C组,差异有统计学意义(P<0.05)。D组图像主观质量评分最高,差异有统计学意义(P<0.05)。延髓、脑室、额叶灰质、额叶白质、小脑内侧、小脑外侧及颞肌肌肉SD与主观质量评分呈明显负相关,SNR与主观质量评分间呈明显正相关,差异有统计学意义(P<0.05)。结论:利用Brain Time Stack图像融合技术对头部CT扫描检查图像处理,动脉期结合前一期及后一期的图像数据在处理后具有更好的质量和更少的噪音。
基金supported in part by Science and Technology Program of Guangdong (No. 2018B030333001)the State’s Key Project of Research and Development Plan (Nos. 2017YFC0109202,2017YFA0104302 and 2017YFC0107900)the National Natural Science Foundation (Nos. 81530060 and 61871117)
文摘Cerebral perfusion computed tomography(PCT)is an important imaging modality for evaluating cerebrovascular diseases and stroke symptoms.With widespread public concern about the potential cancer risks and health hazards associated with cumulative radiation exposure in PCT imaging,considerable research has been conducted to reduce the radiation dose in X-ray-based brain perfusion imaging.Reducing the dose of X-rays causes severe noise and artifacts in PCT images.To solve this problem,we propose a deep learning method called NCS-Unet.The exceptional characteristics of non-subsampled contourlet transform(NSCT)and the Sobel filter are introduced into NCS-Unet.NSCT decomposes the convolved features into high-and low-frequency components.The decomposed high-frequency component retains image edges,contrast imaging traces,and noise,whereas the low-frequency component retains the main image information.The Sobel filter extracts the contours of the original image and the imaging traces caused by the contrast agent decay.The extracted information is added to NCS-Unet to improve its performance in noise reduction and artifact removal.Qualitative and quantitative analyses demonstrated that the proposed NCS-Unet can improve the quality of low-dose cone-beam CT perfusion reconstruction images and the accuracy of perfusion parameter calculations.
文摘In order to effectively improve the pathological diagnosis capability and feature resolution of 3D human brain CT images,a threshold segmentation method of multi-resolution 3D human brain CT image based on edge pixel grayscale feature decomposition is proposed in this paper.In this method,first,original 3D human brain image information is collected,and CT image filtering is performed to the collected information through the gradient value decomposition method,and edge contour features of the 3D human brain CT image are extracted.Then,the threshold segmentation method is adopted to segment the regional pixel feature block of the 3D human brain CT image to segment the image into block vectors with high-resolution feature points,and the 3D human brain CT image is reconstructed with the salient feature point as center.Simulation results show that the method proposed in this paper can provide accuracy up to 100%when the signal-to-noise ratio is 0,and with the increase of signal-to-noise ratio,the accuracy provided by this method is stable at 100%.Comparison results show that the threshold segmentation method of multi-resolution 3D human brain CT image based on edge pixel grayscale feature decomposition is signicantly better than traditional methods in pathological feature estimation accuracy,and it effectively improves the rapid pathological diagnosis and positioning recognition abilities to CT images.