期刊文献+
共找到3,091篇文章
< 1 2 155 >
每页显示 20 50 100
Echo contrast medium:How the use of contrast echocardiography(ultrasound contrast agents)can improve patient care
1
作者 Kevan English 《World Journal of Methodology》 2025年第3期32-37,共6页
Conventional echocardiography can sometimes pose a challenge to diagnosis due to sub-optimal images.Ultrasound contrast agents(UCAs)have been shown to drastically enhance imaging quality,particularly depicting the lef... Conventional echocardiography can sometimes pose a challenge to diagnosis due to sub-optimal images.Ultrasound contrast agents(UCAs)have been shown to drastically enhance imaging quality,particularly depicting the left ventricular endocardial borders.Their use during echocardiography has become a valuable tool in non-invasive diagnostics.UCAs provide higher-quality images that may ultimately reduce the length of hospital stays and improve patient care.The higher cost associated with UCAs in many situations has been an impediment to frequent use.However,when used as an initial diagnostic test,UCA during rest echocardiogram is more cost-effective than the traditional diagnostic approach,which frequently includes multiple tests and imaging studies to make an accurate diagnosis.They can be easily performed across multiple patient settings and provide optimal images that allow clinicians to make sound medical decisions.This consequently allows for better diagnostic accuracies and improvement in patient care. 展开更多
关键词 Ultrasound contrast agents ECHOcaRDIOGRAPHY Myocardial perfusion ULTRASOUND Left ventricle OPTISON DEFINITY SONAZOID Lumason
在线阅读 下载PDF
Near-Infrared Fluorescence Imaging Contrast Agents for Clinical Research: Limitations and Alternatives
2
作者 Serigne Moussa Badiane Elhadji A. L. Bathily +1 位作者 Fawrou Seye Louis A.D. Diouf 《Open Journal of Biophysics》 2024年第1期73-77,共5页
Introduction: Near-infrared fluorescence imaging is a technique that will establish itself in the short term at the international level because it is recognized for its potential to improve the performance of surgical... Introduction: Near-infrared fluorescence imaging is a technique that will establish itself in the short term at the international level because it is recognized for its potential to improve the performance of surgical interventions, its moderate investment and operating costs and its portability. Although the technology is now mature, there is currently the problem of the availability of contrast agents to be injected IV. The aim of this methodology article is to propose an alternative solution to the need for contrast agents for clinical research, particularly in oncology. Methodology: They consist of coupling a fluorescent marker in the form of an NHS derivative, such as IR DYE manufactured in compliance with GMP, with therapeutic monoclonal antibodies having marketing authorization for molecular imaging. For a given antibody, the marking procedure must be the subject of a validation file on the final preparation filtered on a sterilizing membrane at 0.22 μm. Once the procedure has been validated, it would be unnecessary to repeat the tests before each clinical research examination. A check of the marking by thin-layer chromatography (TLC) and place it in a sample bank at +4˚C for 1 month of each injected formulation would be sufficient for additional tests if necessary. Conclusion: Molecular near-infrared fluorescence imaging is experiencing development, the process of which could be accelerated by greater availability of clinical contrast agents. Alternative solutions are therefore necessary to promote clinical research in this area. These methods must be shared to make it easier for researchers. 展开更多
关键词 Fluorescence Imaging contrast agents Clinical Research
在线阅读 下载PDF
Correlation study of biological characteristics of non-small cell lung cancer A549 cells after transfecting plasmid by microbubble ultrasound contrast agent 被引量:3
3
作者 Xuan-Yan Guo Man-Lu +2 位作者 Xue-Qing Chen Fan-Ding He Ang-Li 《Asian Pacific Journal of Tropical Medicine》 SCIE CAS 2016年第6期564-567,共4页
Objective: To explore the role of the abnormal expression of miRNAs in the development process of non-small cell lung cancer and the feasibility of ultrasound microbubble-mediated gene therapy after transfecting antis... Objective: To explore the role of the abnormal expression of miRNAs in the development process of non-small cell lung cancer and the feasibility of ultrasound microbubble-mediated gene therapy after transfecting antisense miRNA-224 and miRNA-122 a plasmids into nonsmall cell lung cancer A549 cells. Methods: Antisense miRNA-224 and miRNA-122 a plasmids were transfected into non-small cell lung cancer A549 cells on the optimal ultrasound microbubble mediated condition. We set up a control group. The cell proliferation activity, apoptosis, invasion ability were detected by MTT assay, Annexin V-PE, Transwell invasion experiment and colony formation assay, respectively. Results: The expression of mi RNA-224 decreased and the expression of miRNA-122 a rose after the plasmids of target genes were transfected into non-small cell lung cancer A549 cells, and there were significant differences when compared with those of the control group(P<0.05). After the plasmids of target genes were transfected into A549 cells, the growth of antisense miRNA-224 and miRNA-122 a were inhibited, and the differences were significant as compared with the control group(P < 0.05). Besides, the inhibition of miRNA-122 a group was the most significant and there was statistically significant difference as compared with miRNA-224 group(t =-4.694, P = 0.009). After the plasmids of target genes were transfected into A549 cells, the proportion of apoptotic cells increased, the invasive cells were decreased and the clone ability reduced, and also there was a significant difference as compared with those of the control group(P < 0.05). What's more, the apoptotic peak appeared in miRNA-122 a group. Its invasion ability decreased most obviously(40.25 ± 3.97/visual field), the number of clone ability was 104.93 ± 4.87 and the inhibitory effect was the most obviously. There was statistically significant difference as compared with other groups(P < 0.05). Conclusions: A549 cells transfected by ultrasound microbubble-mediated antisense miRNA-224 and mi RNA-122 a plasmids possessed good transfection efficiency. The cell growth, invasion and colony forming abilities of transfected A549 cells were suppressed, which laid a solid foundation for the gene therapy of non-small cell lung cancer. 展开更多
关键词 MICROBUBBLE ultrasound contrast agent MiR-224 MiR-122a NON-SMALL cell LUNG cancer
在线阅读 下载PDF
Application of Low Tube Voltage, Low-concentration Contrast Agent Using a 320-row CT in Coronary CT Angiography: Evaluation of Image Quality, Radiation Dose and Iodine Intake 被引量:11
4
作者 Yue-ying PAN Shu-chang ZHOU +4 位作者 Yu-jin WANG Qian LI Ting-ting ZHU Chun-xia LIU Han-xiong GUAN 《Current Medical Science》 SCIE CAS 2020年第1期178-183,共6页
The effect of low voltage and low concentration contrast agent on image quality of coronary CT angiography,radiation dose and iodine intake was evaluated.A total of 121 patients with body mass index(BMI)<26 kg/m2 a... The effect of low voltage and low concentration contrast agent on image quality of coronary CT angiography,radiation dose and iodine intake was evaluated.A total of 121 patients with body mass index(BMI)<26 kg/m2 and heart rate(HR)<70 beats/min were randomly divided into four groups:group A(n=31,80 kVp,270 mgl/mL);group B(n=33,100 kVp,270 mgl/mL);group C(h=30,100 kVp,320 mgl/mL);group D(w=27,100 kVp,400 mgl/mL).The automatic current modulation system and the iterative algorithm for reconstruction were adopted in each group.The CT values and SD values of the aortic root(AR),subcutaneous fat,left coronary artery opening(LCA),and right coronary artery opening(RCA)were measured in all groups,the signalto-noise ratio(SNR)and contrast noise ratio(CNR)were calculated,and effective radiation dose and iodine intake were recorded.The subjective assessment for image quality was performed by two physicians using a 4-point scale.The results were compared using the one-way ANOVA and rank sum tests.The image quality of the four groups met the clinical diagnostic requirements.The CT values of AR in groups A,B,C,and D were 537.6±71.4,447.2±81.9,445.2±64.9 and 518.5±94.9 Hu,respectively,with no significant difference between group A and group D,or between group B and group C,while CT values in groups B and C were significantly lower than those in groups A and D(P<0.05).In groups A,B,C,and D,the LCA SNR values were 22.7±9.1,23.3±9.1,23.3±7.7 and 26.6±8.9,and the RCA CNR values were 26.9±9.&28.5±11.4,27.7土&8 and 32」±10.6,respectively.The AR visual scores in groups A,B,C and D were 3.8±0.2,3.9±0.3,3.9±0.3 and 4.0±0.3,respectively.There were no significant differences in SNR,CNR and visual score among the four groups(P>0.05).The radiation doses in groups A,B,C and D were 2.6±1.4,3.6±1.&4.9±3.5 and 4.9±2.8 mSv,respectively.The radiation dose in group A was significantly less than that in the rest three groups(P<0.05).The iodine intakes in groups A,B,C and D were 14.9±1.5,15.0±1.5,17.7±2.0 and 18.1±2.5 g,respectively.There was no significant difference in the intake of iodine between groups C and D,or between groups A and B,while iodine intake in groups A and B were significantly reduced as compared with that in groups C and D(P<0.05).It was concluded that for patients with low BMI and controlled HR,compared to 100 kVp tube voltage combined with multiple concentration contrast agents,80 kVp combined with 270 mgl/mL contrast agent is enough to ensure the quality of the images,and can reduce the radiation dose significantly,while reducing the amount of iodine intake notably,thus reducing the incidence of adverse reaction. 展开更多
关键词 tube voltage contrast agent coronary CT angiography radiation dose iodine intake
在线阅读 下载PDF
A contrast study on different gasifying agents of underground coal gasification at Huating Coal Mine 被引量:13
5
作者 WANG Zuo-tang HUANG Wen-gang +1 位作者 ZHANG Peng XIN Lin 《Journal of Coal Science & Engineering(China)》 2011年第2期181-186,共6页
To optimize the technological parameter of underground coal gasification (UCG), the experimental results of air gasification, air-steam gasification, oxygen-enrichment steam gasification, pure oxygen steam gasificat... To optimize the technological parameter of underground coal gasification (UCG), the experimental results of air gasification, air-steam gasification, oxygen-enrichment steam gasification, pure oxygen steam gasification and two-stage gasification were studied contrastively based on field trial at the Huating UCG project. The results indicate that the average low heat value of gas from air experiment is the lowest (4.1 MJ/Nm3) and the water gas from two-stage gasification experiment is the highest (10.72 MJ/Nm3). The gas productivity of air gasification is the highest and the pure oxygen steam gasification is the lowest. The gasification efficiency of air gasification, air-steam gasification, oxygen-enriched steam gasification, pure oxygen steam gasification and two-stage gasification is listed in ascending order, ranging from 69.88% to 84.81%. Described a contract study on results of a field test using steam and various levels of oxygen enrichment of 21%, 32%, 42% and 100%. The results show that, with the increasing of O2 content in gasifying agents, the gas caloricity rises, and the optimal O2 concentration range to increase the gas caloricity is 30%-40%. Meanwhile, the consumption of O2 and steam increase, and the air consumption and steam decomposition efficiency fall. 展开更多
关键词 contrast study gasifying agent underground coal gasification (UCG) field trial
在线阅读 下载PDF
Contrast-enhanced ultrasound using SonoVue mixed with oral gastrointestinal contrast agent to evaluate esophageal hiatal hernia: Report of three cases and a literature review 被引量:7
6
作者 Jing-Yu Wang Yan Luo +4 位作者 Wen-Ying Wang Shi-Cheng Zheng Lian He Chun-Yan Xie Li Peng 《World Journal of Clinical Cases》 SCIE 2021年第11期2679-2687,共9页
BACKGROUND Due to a thicker abdominal wall in some patients,ultrasound artifacts from gastrointestinal gas and surrounding tissues can interfere with routine ultrasound examination,precluding its ability to display or... BACKGROUND Due to a thicker abdominal wall in some patients,ultrasound artifacts from gastrointestinal gas and surrounding tissues can interfere with routine ultrasound examination,precluding its ability to display or clearly show the structure of a hernial sac(HS)and thereby diminishing diagnostic performance for esophageal hiatal hernia(EHH).Contrast-enhanced ultrasound(CEUS)imaging using an oral agent mixture allows for clear and intuitive identification of an EHH sac and dynamic observation of esophageal reflux.CASE SUMMARY In this case series,we report three patients with clinically-suspected EHH,including two females and one male with an average age of 67.3±16.4 years.CEUS was administered with an oral agent mixture(microbubble-based SonoVue and gastrointestinal contrast agent)and identified a direct sign of supradiaphragmatic HS(containing the hyperechoic agent)and indirect signs[e.g.,widening of esophageal hiatus,hyperechoic mixture agent continuously or intermittently reflux flowing back and forth from the stomach into the supradiaphragmatic HS,and esophagus-gastric echo ring(i.e.,the“EG”ring)seen above the diaphragm].All three cases received a definitive diagnosis of EHH by esophageal manometry and gastroscopy.Two lesions resolved upon drug treatment and one required surgery.The recurrence rate in follow-up was 0%.The data from these cases suggest that the new non-invasive examination method may greatly improve the diagnosis of EHH.CONCLUSION CEUS with the oral agent mixture can facilitate clear and intuitive identification of HS and dynamic observation of esophageal reflux. 展开更多
关键词 SONOVUE Oral gastrointestinal contrast agent contrast-enhanced ultrasound GASTROINTESTINAL Hiatal hernia case report
在线阅读 下载PDF
Non-thermal ablation of rabbit liver VX2 tumor by pulsed high intensity focused ultrasound with ultrasound contrast agent:Pathological characteristics 被引量:6
7
作者 Cheng-Wen Zhou Fa-Qi Li +3 位作者 Yan Qin Chun-Mei Liu Xiao-Lin Zheng Zhi-Biao Wang 《World Journal of Gastroenterology》 SCIE CAS CSCD 2008年第43期6743-6747,共5页
AIM: To investigate the pathological characteristics of non-thermal damage induced by pulsed high intensity focused ultrasound (PHIFU) combined with ultrasound contrast agent (UCA), SonoVue (Bracco SpA, Milan, I... AIM: To investigate the pathological characteristics of non-thermal damage induced by pulsed high intensity focused ultrasound (PHIFU) combined with ultrasound contrast agent (UCA), SonoVue (Bracco SpA, Milan, Italy) in rabbit liver VX2 tumor. METHODS: Liver VX2 tumor models were established in 20 rabbits, which were divided randomly into PHIFU combined with ultrasound contrast agent group (PHIFU + UCA group) and sham group. In the PHIFU + UCA group, 0.2 mL of SonoVue was injected intravenously into the tumor, followed by ultrasound exposure of Isp 5900 W/cm^2. The rabbits were sacrificed one day after ultrasound exposure. Specimens of the exposed tumor tissues were obtained and observed pathologically under light microscope and transmission electron microscope. The remaining tumor tissues were sent for 2,3,5-Triphenyltetrazolium chloride (TTC) staining. RESULTS: Before Trc staining, tumor tissues in both the sham and the PHIFU + UCA groups resembled gray fish meat, After TIC staining, the tumor tissues were uniformly stained red, with a clear boundary between tumor tissue and normal tissue, Histological examination showed signs of tumor cell injury in PHIFU + UCA group, with cytoplasmic vacuoles of various sizes, chromatin margination and karyopyknosis. Electron microscopic examination revealed tumor cell volume reduction, karyopyknosis, chromatin margination, intercellular space widening, the presence of high electro'n-density apoptotic bodies and vacuoles in cytoplasm. CONCLUSION: The non-thermal effects of PHIFU combined with UCA can be used to ablate rabbit liver VX2 tumors. 展开更多
关键词 Pulsed high intensity focused ultrasound Ultrasound contrast agent Non-thermal effects Rabbitliver VX2 tumors HISTOPATHOLOGY
在线阅读 下载PDF
Gilbert syndrome combined with prolonged jaundice caused by contrast agent:Case report 被引量:1
8
作者 Jian-Dan Qian Feng-Qin Hou +2 位作者 Tai-Ling Wang Chen Shao Gui-Qiang Wang 《World Journal of Gastroenterology》 SCIE CAS 2018年第13期1486-1490,共5页
This case highlights a patient with Gilbert syndrome who underwent endoscopic retrograde cholangiopancreatography(ERCP) with removal of bile duct stones, who then experienced an unexplained increase in bilirubin, with... This case highlights a patient with Gilbert syndrome who underwent endoscopic retrograde cholangiopancreatography(ERCP) with removal of bile duct stones, who then experienced an unexplained increase in bilirubin, with total bilirubin(TBIL) levels increasing from 159.5 μmol/L to 396.2 μmol/L and to a maximum of 502.8 μmol/L after 9 d. Following the decrease in the TBIL level, enhanced magnetic resonance cholangiopancreatography(MRCP) was performed to exclude any possible remaining choledocholithiasis. Nevertheless, the serum bilirubin level increased again, with TBIL levels rising from 455.7 μmol/L to 594.8 μmol/L and a maximum level of 660.3 μmol/L with no remaining bile duct stones. A liver biopsy showed severe bile duct cholestasis with no inflammation. Based on the exclusion of other potential causes of hyperbilirubinemia and the fact that both instances of increased bilirubin occurred after ERCP and MRCP, the contrast agents iopromide and gadoterate meglumine were suspected to be the causes of the hyperbilirubinemia. As of the writing of this report, the patient's bilirubin levels have spontaneously returned to baseline levels. In summary,ERCP and MRCP utilizing the contrast agents iopromide and gadoterate meglumine may possibly induce prolonged hyperbilirubinemia. 展开更多
关键词 contrast agent IOPROMIDE Gadoterate MEGLUMINE Gilbert SYNDROME JAUNDICE
在线阅读 下载PDF
Optimized energy thresholds in a spectral computed tomography scan for contrast agent imaging 被引量:1
9
作者 Kai-Xin Huang Zhi Deng +1 位作者 Xiao-Fei Xu Yu-Xiang Xing 《Nuclear Science and Techniques》 SCIE CAS CSCD 2019年第3期15-27,共13页
Spectral computed tomography(CT) based on photon counting detectors(PCDs) is a well-researched topic in the field of X-ray imaging. When PCD is applied in a spectral CT system, the PCD energy thresholds must be carefu... Spectral computed tomography(CT) based on photon counting detectors(PCDs) is a well-researched topic in the field of X-ray imaging. When PCD is applied in a spectral CT system, the PCD energy thresholds must be carefully selected, especially for K-edge imaging, which is an important spectral CT application. This paper presents a threshold selection method that yields better-quality images in K-edge imaging. The main idea is to optimize the energy thresholds ray-by-ray according to the targeted component coefficients, followed by obtaining an overall optimal energy threshold by frequency voting. A low-dose pre-scan is used in practical implementations to estimate the line integrals of the component coefficients for the basis functions. The variance of the decomposed component coefficients is then minimized using the Cramer–Rao lower bound method with respect to the energy thresholds. The optimal energy thresholds are then used to take a full scan and gain better image reconstruction with less noise than would be given by a full scan using the non-optimal energy thresholds. Simulations and practical experiments on imaging iodine and gadolinium solutions, which are commonly used as contrast agents in medical applications, were used to validate the method. The noise was significantly reduced with the same dose relative to the non-optimal energy thresholds in both simulations and in practical experiments. 展开更多
关键词 SPECTRAL CT contrast agent IMAGING Cramer-Rao LOWER BOUND Thresholds optimization Kedge
在线阅读 下载PDF
Study on Multi-density Contrast Agent Fillers of Duct Casting Based on CT Three-Dimensional Reconstruction 被引量:5
10
作者 黄海龙 陈进军 +2 位作者 王瑜 陈小宇 龚达聪 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2017年第2期300-306,共7页
The three-dimensional visualization model of human body duct is based on virtual anatomical structure reconstruction with duct angiography,which realizes virtual model transferred from two-dimensional,planar and stati... The three-dimensional visualization model of human body duct is based on virtual anatomical structure reconstruction with duct angiography,which realizes virtual model transferred from two-dimensional,planar and static images into three-dimensional,stereoscopic and dynamic ones repectively.In recent years,the multi-duct segmentation and division of the same specimen(or organ) is the focus of attention shared by surgeons and clinical anatomists.On the basis of 4.22 g/cm3 body bone density,this study has screened out metal oxide contract agent with different density for infusion and modeling,as well as compared and analyzed the effects of three-dimensional image of CT virtual bronchoscopy(CTVB),three-dimensional image of CT maximum intensity projection and three-dimensional model.This experiment result showed synchronously infusing multi-duct of same specimen(or organ) with contrast agent in different densities could reconstruct three-dimensional models of all ducts once only and adjust threshold to develop single or multiple ducts.It was easier to segment and observe the duct structure,anastomosis,directions and crossing in different parts,which was beyond comparison with three-dimensional image of CTVB.Although the existing three-dimensional duct reconstruction techniques still cannot be applied in living bodies temporarily,this study focused on a creative design of ducts segmentation in different density,which proposed a new experimental idea for developing multi-duct three-dimensional model in living body in the future.It will play a significant role in disease diagnosis and individual design in surgical treatment program.Therefore,this study observes the three-dimensional status of human duct with the application of contrast agent fillers in different density,combined with three-dimensional reconstruction technology.It provides an innovative idea and method for constructing three-dimensional model of digital multi-duct specimen,and the ultimate goal is to develop the digitized virtual human and precise medical treatment better and faster. 展开更多
关键词 bronchi of pig lung three-dimensional reconstruction contrast agent density difference duct casting
在线阅读 下载PDF
Lactoferrin-Conjugated Polylactic Acid Nanobubbles Encapsulated Perfluoropentane as a Contrast Agent for Ultrasound/Magnetic Resonance Dual-Modality Imaging 被引量:1
11
作者 Liqiong Ding Pingsheng Li +3 位作者 Liu He Fengnan Xu Jieqiong Ding Binhua Luo 《Journal of Renewable Materials》 SCIE EI 2022年第3期767-780,共14页
The development of contrast agents that can be activated by multiple modes is of great significance for tumor diagnosis.In this study,the lactoferrin(Lf)-conjugated polylactic acid(PLLA)nanobubbles(Lf-PLLA NBs)were us... The development of contrast agents that can be activated by multiple modes is of great significance for tumor diagnosis.In this study,the lactoferrin(Lf)-conjugated polylactic acid(PLLA)nanobubbles(Lf-PLLA NBs)were used to encapsulate liquid perfluoropentane(PFP)with the double emulsion method,creating PFP loaded(PFP/Lf-PLLA)NBs for the ultrasound/magnetic resonance dual-modality imaging of subcutaneous tumor.The parti-cle diameter and stability of nanobubbles were investigated by photon correlation spectroscopy.The biocompat-ibility of nanobubbles was preliminarily evaluated by cell proliferation and migration assay,hemolysis rate,and blood biochemistry analysis.A B-mode clinical ultrasound real-time imaging system was used to perform ultra-sonic imaging in vivo.Magnetic resonance imaging in vivo was applied with a clinical 3.0 T magnetic resonance imaging(MRI)scanner system.The mean particle diameter of PFP/Lf-PLLA NBs was 320.2±4.1 nm with a low polydispersity index(PDI,0.145±0.025),and the NBs were negatively charged(−11.4±0.4 mV).The transmis-sion electron microscopy(TEM)results showed that PFP/Lf-PLLA NBs exhibited highly monodispersed and pos-sessed an obvious spherical structure of nanocapsules.Nanobubbles had good stability at 4°C.Different concentrations of the PFP/Lf-PLLA NBs solution had no effect on the cell in cytotoxicity and cell migration,and the results of hemolysis rate and blood biochemistry assay also indicated the good biocompatibility of NBs.On the ultrasound/magnetic resonance imaging of tumor-bearing mice,PFP/Lf-PLLA NBs showed signifi-cantly enhanced contrast ability of tumor tissue.Therefore,PFP/Lf-PLLA NBs had great potential to be a contrast agent for tumor dual-modality imaging in vivo. 展开更多
关键词 LACTOFERRIN polylactic acid NANOBUBBLES contrast agent ultrasound/magnetic resonance imaging
在线阅读 下载PDF
Dynamics of an ultrasound contrast agent microbubble near spherical boundary in ultrasound field
12
作者 Ji-Wen Hu Lian-Mei Wang +3 位作者 Sheng-You Qian Wen-Yi Liu Ya-Tao Liu Wei-Rui Lei 《Chinese Physics B》 SCIE EI CAS CSCD 2019年第11期204-209,共6页
The goal of this article is to establish the conditions of excitation where one has to deal with ultrasound contrast agent(UCA) microbubbles pulsating near biological tissues with spherical boundary in ultrasound fiel... The goal of this article is to establish the conditions of excitation where one has to deal with ultrasound contrast agent(UCA) microbubbles pulsating near biological tissues with spherical boundary in ultrasound field for targeted drug delivery and cavitation-enhanced thrombolysis, etc., and contributes to understanding of mechanisms at play in such an interaction. A modified model is presented for describing microbubble dynamics near a spherical boundary(including convex boundary and concave boundary) with an arbitrary-sized aperture angle. The novelty of the model is such that an oscillating microbubble is influenced by an additional pressure produced by the sound reflection from the boundary wall. It is found that the amplitude of microbubble oscillation is positively correlated to the curve radius of the wall and negatively correlated to the aperture angle of the wall and the sound reflection coefficient. Moreover, the natural frequency of the microbubble oscillation for such a compliable wall increases with the wall compliance, but decreases with the reduction of the wall size, indicating distinct increase of the natural frequency compared to a common rigid wall. The proposed model may allow obtaining accurate information on the radiation force and signals that may be used to advantage in related as drug delivery and contrast agent imaging. 展开更多
关键词 ULTRASOUND contrast agent(Uca) MICROBUBBLE SPHERIcaL BOUNDARY ULTRASOUND natural frequency
在线阅读 下载PDF
Nanomaterials incorporated ultrasound contrast agents for cancer theranostics
13
作者 Lei Fu Heng-Te Ke 《Cancer Biology & Medicine》 SCIE CAS CSCD 2016年第3期313-324,共12页
Nanotechnology provides various nanomaterials with tremendous functionalities for cancer diagnostics and therapeutics.Recently, theranostics has been developed as an alternative strategy for efficient cancer treatment... Nanotechnology provides various nanomaterials with tremendous functionalities for cancer diagnostics and therapeutics.Recently, theranostics has been developed as an alternative strategy for efficient cancer treatment through combination of imaging diagnosis and therapeutic interventions under the guidance of diagnostic results. Ultrasound(US) imaging shows unique advantages with excellent features of real-time imaging, low cost, high safety and portability, making US contrast agents(UCAs)an ideal platform for construction of cancer theranostic agents. This review focuses on the development of nanomaterials incorporated multifunctional UCAs serving as theranostic agents for cancer diagnostics and therapeutics, via conjugation of superparamagnetic iron oxide nanoparticles(SPIOs), Cu S nanoparticles, DNA, si RNA, gold nanoparticles(GNPs), gold nanorods(GNRs), gold nanoshell(GNS), graphene oxides(GOs), polypyrrole(PPy) nanocapsules, Prussian blue(PB) nanoparticles and so on to different types of UCAs. The cancer treatment could be more effectively and accurately carried out under the guidance and monitoring with the help of the achieved theranostic agents. Furthermore, nanomaterials incorporated theranostic agents based on UCAs can be designed and constructed by demand for personalized and accurate treatment of cancer, demonstrating their great potential to address the challenges of cancer heterogeneity and adaptation, which can provide alternative strategies for cancer diagnosis and therapeutics. 展开更多
关键词 caNCER THERANOSTICS ultrasound contrast agents NANOMATERIALS NANOMEDICINE
在线阅读 下载PDF
Dynamic Assessment of the Focal Hepatic Lesion in Rats Using Ultrasonic Contrast Agent
14
作者 张超 邓又斌 +1 位作者 黄道中 张青萍 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2006年第3期332-333,368,共3页
The focal hepatic lesion caused by local injection of absolute alcohol in rats was evaluated with ultrasonic contrast agent and pathologic examination. Twenty adult Wistar rats weighing about 200 g were injected with ... The focal hepatic lesion caused by local injection of absolute alcohol in rats was evaluated with ultrasonic contrast agent and pathologic examination. Twenty adult Wistar rats weighing about 200 g were injected with absolute alcohol (0. 05-0. 1 mL each one) on the exterior left lobe of the liver under the monitoring of ultrasound. Pulse inversion harmonic imaging was used to evaluate the focal lesion after bolus injection of ultrasonic contrast agent (0. 05 mL/200 g) through caudal vein. Seven days later, the focal lesion was studied again as before. The exterior left lobe of liver with focal lesion was incised and underwent pathologic examination. The results showed that all of the focal lesions could be defined clearly after bolus injection of the ultrasonic contrast agent under the mode of pulse inversion harmonic imaging. There was good correlation between the size of the focal lesion measured by ultrasound on the 7th day after the "ablation" under the mode of pulse inversion harmonic imaging and that gotten by pathologic examination (P=0.39). The focus size measured by ultrasound right after the ablation was larger than that gotten by pathologic examination (P=0. 002). It was concluded that ultrasonic contrast agent plus pulse inversion harmonic imaging could be used to assess the size of the focal hepatic lesion caused by local injection of absolute alcohol in rats. 展开更多
关键词 pulse inversion harmonic imaging ultrasonic contrast agent PATHOLOGY
在线阅读 下载PDF
The Applicability of Gd-DTPA Magnetic Resonance Imaging Contrast Agent for the Evaluation of Blood Compartment Flow Distribution in Hollow Fiber Hemodialyzers
15
作者 Bimali Sanjeevani Weerakoon Toshiaki Osuga 《Journal of Biomedical Science and Engineering》 2015年第11期789-796,共8页
Observation of flow distribution pattern in the hemodialyzers is significant as it is a valuable in-dication of the performance of these modules. Therefore, in this study, a feasible non-destructive Magnetic Resonance... Observation of flow distribution pattern in the hemodialyzers is significant as it is a valuable in-dication of the performance of these modules. Therefore, in this study, a feasible non-destructive Magnetic Resonance Imaging (MRI) technique is proposed to characterize the flow distribution in the blood compartment of hemodialyzers using Gd-DTPA MRI contrast agent. The distribution of flow is qualitatively observed in two commercial clinical dialyzers through an in-vitro experiment. The contrast enhanced T1 weighted images are acquired along the dialyzer length using Spin Echo (SE) pulse sequence after an injection of 0.5 mmol/L Gd-DTPA solution into the blood compartment. Although relatively uniform flow distribution pattern over the spatial volume of transverse images, close the dialyzer inlet is observed, the heterogeneity of flow distribution can be identified towards the blood outlet port. Furthermore, the signal intensity profiles formed by the injected Gd-DTPA are gradually decreased towards the outlet port. These results of the study suggest that although no advanced techniques and protocols available, MRI and Gd-DTPA contrast agent can be utilized to characterize the flow distribution within a dialyzer qualitatively. 展开更多
关键词 Hemodialyzer Magnetic Resonance Imaging GD-DTPA contrast agent
在线阅读 下载PDF
Microbubble ultrasound contrast agent with three esters and carboxylic methyl cellulose as main shell materials: Its preparation and imaging evaluation
16
作者 杜永峰 万明习 周晓东 《Journal of Medical Colleges of PLA(China)》 CAS 2003年第2期109-114,共6页
Objective: To study on the preparation process of a new surfactant-based microbubble ultrasound contrast agent and to evaluate its contrast effects in vivo. Methods: Microbubble ultrasound contrast agent with three es... Objective: To study on the preparation process of a new surfactant-based microbubble ultrasound contrast agent and to evaluate its contrast effects in vivo. Methods: Microbubble ultrasound contrast agent with three ester surfactants and other additives as its shell materials was prepared by sonication. Sulfur hexafluoride was adopted as the inner gas of the microbubbles. New methods through the combination of optical microscope and some softwares were used to measure the size distribution and the concentration of the microbubbles. Some parameters such as the pH value of the phosphate buffer, quantity of the carboxylic methyl cellulose in the shell materials, selection of the ultrasound power and process time, were studied. Six hybirded dogs were used to verify the in vivo contrast imaging of the contrast agent using second harmonic power Doppler modality. Safety and persistent time of the agent inner animal body were also investigated. Results: Ultrasound contrast agent prepared in the experiment had an average microbubble diameter of 3.95 microns with concentration of 3.6×109 microbubbles per millilitre. Carboxylic methyl cellulose was found as an important shell material which had obviously effect on the microbubble stability and production even with a little quantity. The buffer pH value also had a key role on the microbubble formation and the final production. When the buffer pH value reached 7.4, there was no microbubble produced. Under the approximate microbubble production, process time could be shorten with the increasing ultrasound power. The obvious ultrasound contrast imaging effects were detected in the dog's heart chamber and liver as well as kidney using only one millilitre agent when diluted. The agent was found safe to the dogs. At the same time, persistent time of the agent was found over 20 min in the dog's body. Conclusion: The new ultrasound contrast agent prepared in the experiment has high microbubble production and concentration, narrow microbubble size distribution ranging in several microns, well stability, little dosage needed in the contrast, well safety to the dogs and long persistent time, obvious contrast imaging effect in the dog's heart chamber, kidney and liver. These experiment data indicate that the new ultrasound contrast agent with three ester surfactants and carboxylic methyl cellulose as its main shell materials can be further developed for clinical purposes. 展开更多
关键词 ultrasound imaging ultrasound contrast agent MICROBUBBLE
在线阅读 下载PDF
The combined time-frequency analysis of the acoustic signals backscattered from ultrasonic contrast agents in the evaluation of the blood perfusion
17
作者 李彬 万明习 王素品 《Journal of Medical Colleges of PLA(China)》 CAS 2004年第4期222-224,共3页
Objective: To analyze the non-periodic, unstable and even chaotic echoes scattered from microbubbles which are extremely sensitive and may easily collapse, fragment or shrink when ultrasound contrast agents are expose... Objective: To analyze the non-periodic, unstable and even chaotic echoes scattered from microbubbles which are extremely sensitive and may easily collapse, fragment or shrink when ultrasound contrast agents are exposed to ultrasound (US) irradiation. Methods: The combined time-frequency analysis was applied to the original signals instead of the traditional Fourier spectral analysis technique. Results: The results obtained from simulation as well as experiment showed that the subharmonic, 2nd harmonic and ultra harmonic of the microbubbles occurred during the oscillation and varied with time. The dependence on the incident ultrasonic amplitude and microbubble parameters were established. Conclusion: The transient echoes backscattered from the ultrasound agent in the evaluation of the blood perfusion can be analyzed thoroughly by the technique of combined-frequency analysis and the time detail of the frequency contents can be revealed. 展开更多
关键词 ultrasound contrast agent HARMONIC combined time-frequency analysis
在线阅读 下载PDF
Prevention and Nursing of Adverse Reaction of Iodine Contrast Agent in CT Enhanced Scanning
18
作者 DING Jianhua 《外文科技期刊数据库(文摘版)医药卫生》 2021年第12期362-364,共5页
Objective: to explore the clinical protective measures against adverse reactions of iodine contrast agent in CT enhanced scanning. Methods: to choose between August 2018 to August 2019 in our hospital 78 routine CT en... Objective: to explore the clinical protective measures against adverse reactions of iodine contrast agent in CT enhanced scanning. Methods: to choose between August 2018 to August 2019 in our hospital 78 routine CT enhanced scan in patients with application of iodine contrast agents as the research object, and randomly divided into control group and group them, and were given routine nursing intervention and comprehensive nursing intervention, compared two groups of patients after nursing satisfaction and adverse reaction rate, and so on and so forth. Results: the nursing satisfaction and adverse reaction rates in the study group were 97.44% and 5.13%, respectively, which were significantly better than those in the control group (74.36% and 25.64%, P<0.05). Conclusion: during the clinical application of CT enhanced scanning technology, if iodine contrast agent is to be used, clinical comprehensive nursing intervention should be paid attention to, so as to better improve nursing satisfaction and reduce the rate of adverse reactions, which is worthy of clinical promotion and popularization. 展开更多
关键词 CT enhanced scanning technology iodine contrast agent adverse reactions nursing measures
在线阅读 下载PDF
Application of Low Iodine Concentration Contrast Agent in CTA Examination of Children with Congenital Heart Disease
19
作者 JIANGWenhong 《外文科技期刊数据库(文摘版)医药卫生》 2022年第7期048-051,共4页
Objective: to apply low iodine concentration contrast agent in CTA examination of children with congenital heart disease, and to analyze and study its diagnostic effect. Methods: taking the period from March 2021 to M... Objective: to apply low iodine concentration contrast agent in CTA examination of children with congenital heart disease, and to analyze and study its diagnostic effect. Methods: taking the period from March 2021 to March 2022 as the study period, 80 children with suspected congenital heart disease treated in our hospital were enrolled. The routine iodine contrast agent scanning examination (370mgl/ml) was performed in group A, and the low concentration iodine contrast agent scanning examination (270mgl/ml) was performed in group B. the value of CTA images, the clarity of CTA images, and the uniformity of contrast agents in the two groups were observed and analyzed. Results: there was no significant difference in the CT value of cardiac cavity between the two groups (P > 0.05);There was no significant difference in CT value between the two groups (P > 0.05);The image clarity of group B was higher than that of group A (P;There was no significant difference in the uniformity of contrast medium between the two groups (P > 0.05). Conclusion: the application of CTA with low concentration iodine contrast agent in the diagnosis of children with congenital heart disease can not only reduce the renal burden of children, but also obtain higher definition CTA images, which is worthy of clinical promotion and application. 展开更多
关键词 low iodine concentration contrast agent congenital heart disease CTA examination CHILDREN
在线阅读 下载PDF
Nonlinear response of ultrasound contrast agent microbubbles:From fundamentals to applications
20
作者 滕旭东 郭霞生 +1 位作者 屠娟 章东 《Chinese Physics B》 SCIE EI CAS CSCD 2016年第12期49-56,共8页
Modelling and biomedical applications of ultrasound contrast agent (UCA) microbubbles have attracted a great deal of attention. In this review, we summarize a series of researches done in our group, including (i) ... Modelling and biomedical applications of ultrasound contrast agent (UCA) microbubbles have attracted a great deal of attention. In this review, we summarize a series of researches done in our group, including (i) the development of an all-in-one solution of characterizing coated bubble parameters based on the light scattering technique and flow cytometry; (ii) a novel bubble dynamic model that takes into consideration both nonlinear shell elasticity and viscosity to eliminate the dependences of bubble shell parameters on bubble size; (iii) the evaluation of UCA inertial cavitation threshold and its relationship with shell parameters; and (iv) the investigations of transfection efficiency and the reduction of cytotoxicity in gene delivery facilitated by UCAs excited by ultrasound exposures. 展开更多
关键词 ultrasound contrast agents MICROBUBBLES nonlinear response inertial cavitation DNA transfec- tion
全文增补中
上一页 1 2 155 下一页 到第
使用帮助 返回顶部