The multi-terminal direct current(DC)grid has extinctive superiorities over the traditional alternating current system in integrating large-scale renewable energy.Both the DC circuit breaker(DCCB)and the current flow ...The multi-terminal direct current(DC)grid has extinctive superiorities over the traditional alternating current system in integrating large-scale renewable energy.Both the DC circuit breaker(DCCB)and the current flow controller(CFC)are demanded to ensure the multiterminal DC grid to operates reliably and flexibly.However,since the CFC and the DCCB are all based on fully controlled semiconductor switches(e.g.,insulated gate bipolar transistor,integrated gate commutated thyristor,etc.),their separation configuration in the multiterminal DC grid will lead to unaffordable implementation costs and conduction power losses.To solve these problems,integrated equipment with both current flow control and fault isolation abilities is proposed,which shares the expensive and duplicated components of CFCs and DCCBs among adjacent lines.In addition,the complicated coordination control of CFCs and DCCBs can be avoided by adopting the integrated equipment in themultiterminal DC grid.In order to examine the current flow control and fault isolation abilities of the integrated equipment,the simulation model of a specific meshed four-terminal DC grid is constructed in the PSCAD/EMTDC software.Finally,the comparison between the integrated equipment and the separate solution is presented a specific result or conclusion needs to be added to the abstract.展开更多
The differences between the data integration of a dynamic database grid (DBG) and that of a distributed database system are analyzed, and three kinds of data integration strategies are given on the background of DBG...The differences between the data integration of a dynamic database grid (DBG) and that of a distributed database system are analyzed, and three kinds of data integration strategies are given on the background of DBG based on Peer to Peer (P2P) framework, including the centralized data integration (CDI) strategy, the distributed data integration (DDI) strategy and the filter-based data integration (FDDI) strategy. CDI calls all the database grid services (DGSs) at a single node, DDI disperses the DGSs to multiple nodes, while FDDI schedules the data integration nodes based on filtering the keywords returned from DGSs. The performance of these three integration strategies are compared with and analyzed by simulation experiments. FDDI is more evident for filtering the keywords with data redundancy increasing. Through the reduction of large amount of data transportation, it effectively shortens the executing time for the task and improves its efficiency.展开更多
We present a new derivative-free optimization algorithm based on the sparse grid numerical integration. The algorithm applies to a smooth nonlinear objective function where calculating its gradient is impossible and e...We present a new derivative-free optimization algorithm based on the sparse grid numerical integration. The algorithm applies to a smooth nonlinear objective function where calculating its gradient is impossible and evaluating its value is also very expensive. The new algorithm has: 1) a unique starting point strategy;2) an effective global search heuristic;and 3) consistent local convergence. These are achieved through a uniform use of sparse grid numerical integration. Numerical experiment result indicates that the algorithm is accurate and efficient, and benchmarks favourably against several state-of-art derivative free algorithms.展开更多
This study presents a comprehensive impact analysis of the rotor angle stability of a proposed international connection between the Philippines and Sabah,Malaysia,as part of the Association of Southeast Asian Nations(...This study presents a comprehensive impact analysis of the rotor angle stability of a proposed international connection between the Philippines and Sabah,Malaysia,as part of the Association of Southeast Asian Nations(ASEAN)Power Grid.This study focuses on modeling and evaluating the dynamic performance of the interconnected system,considering the high penetration of renewable sources.Power flow,small signal stability,and transient stability analyses were conducted to assess the ability of the proposed linked power system models to withstand small and large disturbances,utilizing the Power Systems Analysis Toolbox(PSAT)software in MATLAB.All components used in the model are documented in the PSAT library.Currently,there is a lack of publicly available studies regarding the implementation of this specific system.Additionally,the study investigates the behavior of a system with a high penetration of renewable energy sources.Based on the findings,this study concludes that a system is generally stable when interconnection is realized,given its appropriate location and dynamic component parameters.Furthermore,the critical eigenvalues of the system also exhibited improvement as the renewable energy sources were augmented.展开更多
The Renewable Energy Grid Integration Week 2022 will be held on October 10-14 in Delft/The Hague,Netherlands.Two symposiums and a workshop will be held during the event,including the 6th E-Mobility Power System Integr...The Renewable Energy Grid Integration Week 2022 will be held on October 10-14 in Delft/The Hague,Netherlands.Two symposiums and a workshop will be held during the event,including the 6th E-Mobility Power System Integration Symposium,the 1st Hydrogen Power System Integration Symposium and the 21st Wind&Solar Integration Workshop.These events are supported by IEC,the Energy Systems Integration Group(ESIG),the Renewables Grid Initiative and the International Battery&Energy Storage Alliance(IBESA).展开更多
On the basis of three geological models and several orebody boundaries, a method of grid subdivision and integral has been proposed to calculate and evaluate the resources of cobalt-rich crusts on the seamounts in the...On the basis of three geological models and several orebody boundaries, a method of grid subdivision and integral has been proposed to calculate and evaluate the resources of cobalt-rich crusts on the seamounts in the central Pacific Ocean. The formulas of this method are deduced and the interface of program module is designed. The method is carried out in the software "Auto mapping system of submarine topography and geomorphology MBChart". This method and program will possibly become a potential tool to calculate the resources of seamounts and determine the target diggings for China' s next Five-year Plan.展开更多
With the continuous development of power electronic devices,intelligent control systems,and other technologies,the voltage level and transmission capacity of voltage source converter (VSC)-high-voltage direct current ...With the continuous development of power electronic devices,intelligent control systems,and other technologies,the voltage level and transmission capacity of voltage source converter (VSC)-high-voltage direct current (HVDC) technology will continue to increase,while the system losses and costs will gradually decrease.Therefore,it can be foreseen that VSC-HVDC transmission technology will be more widely applied in future large-scale renewable energy development projects.Adopting VSC-HVDC transmission technology can be used to overcome issues encountered by large-scale renewable energy transmission and integration projects,such as a weak local power grid,lack of support for synchronous power supply,and insufficient accommodation capacity.However,this solution also faces many technical challenges because of the differences between renewable energy and traditional synchronous power generation systems.Based on actual engineering practices that are used worldwide,this article analyzes the technical challenges encountered by integrating large-scale renewable energy systems that adopt the use of VSC-HVDC technology,while aiming to provide support for future research and engineering projects related to VSC-HVDC-based large-scale renewable energy integration projects.展开更多
Based on conventional static line rating method, the actual current carrying capability of overhead conductors cannot be judged. Due to continuous increment in electricity demand and the difficulties associated with n...Based on conventional static line rating method, the actual current carrying capability of overhead conductors cannot be judged. Due to continuous increment in electricity demand and the difficulties associated with new line constructions, the overhead lines are therefore required to be rated based on a method that should establish their real-time capability in terms of electricity transmission. The method used to determine the real-time ampacity of overhead conductors not only can enhance their transmission capacity but can also help in allowing excessive renewable generation in the electricity network. In this research work, the issues related to analyzing an impact of wind power on periodical loading of overhead line as well as finding its static and dynamic ampacities with line current are investigated in detail. Moreover, the investigation related to finding a suitable location for the construction of a 60 MW wind farm is taken on board. Thereafter, the wind park is integrated with a regional grid, owned by Fortum Distribution AB. In addition to that, the electricity generated from the wind park is also calculated in this project. Later on, the work is devoted to finding the static and dynamic line ratings for “VL3” overhead conductor by using IEEE-738-2006 standard. Furthermore, the project also deals with finding the line current and making its comparison with maximum capacity of overhead conductor (VL3) for loading it in such a way that no any violation of safe ground clearance requirements is observed at all. Besides, the line current, knowing the conductor temperature when it transmits the required electricity in the presence of wind power generation is also an important factor to be taken into consideration. Therefore, based on real-time ambient conditions with actual line loading and with the help of IEEE-738-2006 standard, the conductor temperature is also calculated in this project. At the end, an economic analysis is performed to evaluate the financial advantages related to applying the dynamic line ratings approach in place of traditional static line ratings technique across an overhead conductor (VL3) and to know how much beneficial it is to temporarily postpone the rebuilding and/or construction of a new transmission line. Furthermore, an economic analysis related to wind power system is taken into consideration as well to get familiar with the costs related to building and connecting a 60 MW wind farm with the regional grid.展开更多
Classical Chinese characters,presented through calligraphy,seal engraving,or painting,can exhibit different aesthetics and essences of Chinese characters,making them the most important asset of the Chinese people.Call...Classical Chinese characters,presented through calligraphy,seal engraving,or painting,can exhibit different aesthetics and essences of Chinese characters,making them the most important asset of the Chinese people.Calligraphy and seal engraving,as two closely related systems in traditional Chinese art,have developed through the ages.Due to changes in lifestyle and advancements in modern technology,their original functions of daily writing and verification have gradually diminished.Instead,they have increasingly played a significant role in commercial art.This study utilizes the Evaluation Grid Method(EGM)and the Analytic Hierarchy Process(AHP)to research the key preference factors in the application of calligraphy and seal engraving imagery.Different from the traditional 5-point equal interval semantic questionnaire,this study employs a non-equal interval semantic questionnaire with a golden ratio scale,distinguishing the importance ratio of adjacent semantic meanings and highlighting the weighted emphasis on visual aesthetics.Additionally,the study uses Importance-Performance Analysis(IPA)and Technique for Order Preference by Similarity to Ideal Solution(TOPSIS)to obtain the key preference sequence of calligraphy and seal engraving culture.Plus,the Choquet integral comprehensive evaluation is used as a reference for IPA comparison.It is hoped that this study can provide cultural imagery references and research methods,injecting further creativity into industrial design.展开更多
The purpose of this study was to clarify grid convergence property of three-dimensional measurement-integrated (3D-MI) simulation for a flow behind a square cylinder with Karman vortex street. Measurement-integrated (...The purpose of this study was to clarify grid convergence property of three-dimensional measurement-integrated (3D-MI) simulation for a flow behind a square cylinder with Karman vortex street. Measurement-integrated (MI) simulation is a kind of the observer in the dynamical system theory by using CFD scheme as a mathematical model of the system. In a former study, two-dimensional MI (2D-MI) simulation with a coarse grid system showed a fairly good result in comparison with a 2D ordinary (2D-O) simulation, but the results were degraded with grid refinement. In this study, 3D-MI simulation and three-dimensional ordinary (3D-O) simulation were performed with three grid systems of different grid resolutions, and their grid convergence properties were compared. As a result, all 3D-MI simulations reproduced the vortex shedding frequency identical to that of the experiment, and the flow fields obtained were very close, within 5% difference between the results, while the results of the 3D-O simulations showed variation of the solution under convergence. It is shown that the grid convergence property of 3D-MI simulation is monotonic and better than that of 3D-O simulation, whereas those of 2D-O and 2D-MI simulations for streamwise velocity fluctuation are divergent. The solution of 3D-MI simulation with a relatively coarse grid system properly reproduces the basic three-dimensional structure of the wake flow as well as the drag and lift coefficients.展开更多
灵活应用电转气(power to gas,P2G)系统中电解水和甲烷化两阶段产出的氢气和甲烷可促进综合能源系统(integratedenergysystem,IES)消纳盈余可再生能源。传统P2G系统只考虑将甲烷作为燃气机组的燃料,未充分利用氢气高电解率的特性,造成...灵活应用电转气(power to gas,P2G)系统中电解水和甲烷化两阶段产出的氢气和甲烷可促进综合能源系统(integratedenergysystem,IES)消纳盈余可再生能源。传统P2G系统只考虑将甲烷作为燃气机组的燃料,未充分利用氢气高电解率的特性,造成能量梯级转化次数增加,能量损耗提高。应用P2G系统两阶段分别产出的氢气和甲烷耦合气网注氢(hydrogen injection into gas grid,HIGG)技术以促进IES中可再生能源的消纳。基于能量枢纽的概念,将IES系统经济性优化调度转化为混合整数规划问题进行求解。通过两个场景的仿真分析说明,相比于仅应用甲烷的传统P2G系统,IES系统中应用P2G和HIGG技术能够降低部分能量梯级转化次数和成本投入,在经济性、环保性方面都有显著提高。展开更多
基金supported in part by Natural Science Foundation of Jiangsu Province under Grant BK20230255Natural Science Foundation of Shandong Province under Grant ZR2023QE281.
文摘The multi-terminal direct current(DC)grid has extinctive superiorities over the traditional alternating current system in integrating large-scale renewable energy.Both the DC circuit breaker(DCCB)and the current flow controller(CFC)are demanded to ensure the multiterminal DC grid to operates reliably and flexibly.However,since the CFC and the DCCB are all based on fully controlled semiconductor switches(e.g.,insulated gate bipolar transistor,integrated gate commutated thyristor,etc.),their separation configuration in the multiterminal DC grid will lead to unaffordable implementation costs and conduction power losses.To solve these problems,integrated equipment with both current flow control and fault isolation abilities is proposed,which shares the expensive and duplicated components of CFCs and DCCBs among adjacent lines.In addition,the complicated coordination control of CFCs and DCCBs can be avoided by adopting the integrated equipment in themultiterminal DC grid.In order to examine the current flow control and fault isolation abilities of the integrated equipment,the simulation model of a specific meshed four-terminal DC grid is constructed in the PSCAD/EMTDC software.Finally,the comparison between the integrated equipment and the separate solution is presented a specific result or conclusion needs to be added to the abstract.
基金Supported by the National High-Technology Re-search and Development Program of China(2003AA414210) the National Natural Science Foundation of China (60573090)
文摘The differences between the data integration of a dynamic database grid (DBG) and that of a distributed database system are analyzed, and three kinds of data integration strategies are given on the background of DBG based on Peer to Peer (P2P) framework, including the centralized data integration (CDI) strategy, the distributed data integration (DDI) strategy and the filter-based data integration (FDDI) strategy. CDI calls all the database grid services (DGSs) at a single node, DDI disperses the DGSs to multiple nodes, while FDDI schedules the data integration nodes based on filtering the keywords returned from DGSs. The performance of these three integration strategies are compared with and analyzed by simulation experiments. FDDI is more evident for filtering the keywords with data redundancy increasing. Through the reduction of large amount of data transportation, it effectively shortens the executing time for the task and improves its efficiency.
文摘We present a new derivative-free optimization algorithm based on the sparse grid numerical integration. The algorithm applies to a smooth nonlinear objective function where calculating its gradient is impossible and evaluating its value is also very expensive. The new algorithm has: 1) a unique starting point strategy;2) an effective global search heuristic;and 3) consistent local convergence. These are achieved through a uniform use of sparse grid numerical integration. Numerical experiment result indicates that the algorithm is accurate and efficient, and benchmarks favourably against several state-of-art derivative free algorithms.
文摘This study presents a comprehensive impact analysis of the rotor angle stability of a proposed international connection between the Philippines and Sabah,Malaysia,as part of the Association of Southeast Asian Nations(ASEAN)Power Grid.This study focuses on modeling and evaluating the dynamic performance of the interconnected system,considering the high penetration of renewable sources.Power flow,small signal stability,and transient stability analyses were conducted to assess the ability of the proposed linked power system models to withstand small and large disturbances,utilizing the Power Systems Analysis Toolbox(PSAT)software in MATLAB.All components used in the model are documented in the PSAT library.Currently,there is a lack of publicly available studies regarding the implementation of this specific system.Additionally,the study investigates the behavior of a system with a high penetration of renewable energy sources.Based on the findings,this study concludes that a system is generally stable when interconnection is realized,given its appropriate location and dynamic component parameters.Furthermore,the critical eigenvalues of the system also exhibited improvement as the renewable energy sources were augmented.
文摘The Renewable Energy Grid Integration Week 2022 will be held on October 10-14 in Delft/The Hague,Netherlands.Two symposiums and a workshop will be held during the event,including the 6th E-Mobility Power System Integration Symposium,the 1st Hydrogen Power System Integration Symposium and the 21st Wind&Solar Integration Workshop.These events are supported by IEC,the Energy Systems Integration Group(ESIG),the Renewables Grid Initiative and the International Battery&Energy Storage Alliance(IBESA).
基金This study was supported by Projects under contract Nos DY105 China's 0cean-03-01-01 and DY105-03-01-07the National Natural Science Foundation of China under contract No.40506017the Youth Foundation of Marine High-tech Project of China under contract No.2002AA616010.
文摘On the basis of three geological models and several orebody boundaries, a method of grid subdivision and integral has been proposed to calculate and evaluate the resources of cobalt-rich crusts on the seamounts in the central Pacific Ocean. The formulas of this method are deduced and the interface of program module is designed. The method is carried out in the software "Auto mapping system of submarine topography and geomorphology MBChart". This method and program will possibly become a potential tool to calculate the resources of seamounts and determine the target diggings for China' s next Five-year Plan.
基金State Grid Corporation of China Science and Technology Project: Research on Power Transmission of Largescale Renewable Energy Base by VSC-LCC hybrid HVDC(No. NY71-19-037)
文摘With the continuous development of power electronic devices,intelligent control systems,and other technologies,the voltage level and transmission capacity of voltage source converter (VSC)-high-voltage direct current (HVDC) technology will continue to increase,while the system losses and costs will gradually decrease.Therefore,it can be foreseen that VSC-HVDC transmission technology will be more widely applied in future large-scale renewable energy development projects.Adopting VSC-HVDC transmission technology can be used to overcome issues encountered by large-scale renewable energy transmission and integration projects,such as a weak local power grid,lack of support for synchronous power supply,and insufficient accommodation capacity.However,this solution also faces many technical challenges because of the differences between renewable energy and traditional synchronous power generation systems.Based on actual engineering practices that are used worldwide,this article analyzes the technical challenges encountered by integrating large-scale renewable energy systems that adopt the use of VSC-HVDC technology,while aiming to provide support for future research and engineering projects related to VSC-HVDC-based large-scale renewable energy integration projects.
文摘Based on conventional static line rating method, the actual current carrying capability of overhead conductors cannot be judged. Due to continuous increment in electricity demand and the difficulties associated with new line constructions, the overhead lines are therefore required to be rated based on a method that should establish their real-time capability in terms of electricity transmission. The method used to determine the real-time ampacity of overhead conductors not only can enhance their transmission capacity but can also help in allowing excessive renewable generation in the electricity network. In this research work, the issues related to analyzing an impact of wind power on periodical loading of overhead line as well as finding its static and dynamic ampacities with line current are investigated in detail. Moreover, the investigation related to finding a suitable location for the construction of a 60 MW wind farm is taken on board. Thereafter, the wind park is integrated with a regional grid, owned by Fortum Distribution AB. In addition to that, the electricity generated from the wind park is also calculated in this project. Later on, the work is devoted to finding the static and dynamic line ratings for “VL3” overhead conductor by using IEEE-738-2006 standard. Furthermore, the project also deals with finding the line current and making its comparison with maximum capacity of overhead conductor (VL3) for loading it in such a way that no any violation of safe ground clearance requirements is observed at all. Besides, the line current, knowing the conductor temperature when it transmits the required electricity in the presence of wind power generation is also an important factor to be taken into consideration. Therefore, based on real-time ambient conditions with actual line loading and with the help of IEEE-738-2006 standard, the conductor temperature is also calculated in this project. At the end, an economic analysis is performed to evaluate the financial advantages related to applying the dynamic line ratings approach in place of traditional static line ratings technique across an overhead conductor (VL3) and to know how much beneficial it is to temporarily postpone the rebuilding and/or construction of a new transmission line. Furthermore, an economic analysis related to wind power system is taken into consideration as well to get familiar with the costs related to building and connecting a 60 MW wind farm with the regional grid.
基金This work is supported in partial by Major State Basic Research Project (No. G19990328, Parallel Computations of the Large-Scale Reservoir Simulation (2003-2004) (Cooperated with China National 0ffshore 0il Corporation), and National Natural Science Foundation Project (No. 60303020, 2004.1-2006.12).
文摘Classical Chinese characters,presented through calligraphy,seal engraving,or painting,can exhibit different aesthetics and essences of Chinese characters,making them the most important asset of the Chinese people.Calligraphy and seal engraving,as two closely related systems in traditional Chinese art,have developed through the ages.Due to changes in lifestyle and advancements in modern technology,their original functions of daily writing and verification have gradually diminished.Instead,they have increasingly played a significant role in commercial art.This study utilizes the Evaluation Grid Method(EGM)and the Analytic Hierarchy Process(AHP)to research the key preference factors in the application of calligraphy and seal engraving imagery.Different from the traditional 5-point equal interval semantic questionnaire,this study employs a non-equal interval semantic questionnaire with a golden ratio scale,distinguishing the importance ratio of adjacent semantic meanings and highlighting the weighted emphasis on visual aesthetics.Additionally,the study uses Importance-Performance Analysis(IPA)and Technique for Order Preference by Similarity to Ideal Solution(TOPSIS)to obtain the key preference sequence of calligraphy and seal engraving culture.Plus,the Choquet integral comprehensive evaluation is used as a reference for IPA comparison.It is hoped that this study can provide cultural imagery references and research methods,injecting further creativity into industrial design.
文摘The purpose of this study was to clarify grid convergence property of three-dimensional measurement-integrated (3D-MI) simulation for a flow behind a square cylinder with Karman vortex street. Measurement-integrated (MI) simulation is a kind of the observer in the dynamical system theory by using CFD scheme as a mathematical model of the system. In a former study, two-dimensional MI (2D-MI) simulation with a coarse grid system showed a fairly good result in comparison with a 2D ordinary (2D-O) simulation, but the results were degraded with grid refinement. In this study, 3D-MI simulation and three-dimensional ordinary (3D-O) simulation were performed with three grid systems of different grid resolutions, and their grid convergence properties were compared. As a result, all 3D-MI simulations reproduced the vortex shedding frequency identical to that of the experiment, and the flow fields obtained were very close, within 5% difference between the results, while the results of the 3D-O simulations showed variation of the solution under convergence. It is shown that the grid convergence property of 3D-MI simulation is monotonic and better than that of 3D-O simulation, whereas those of 2D-O and 2D-MI simulations for streamwise velocity fluctuation are divergent. The solution of 3D-MI simulation with a relatively coarse grid system properly reproduces the basic three-dimensional structure of the wake flow as well as the drag and lift coefficients.
文摘灵活应用电转气(power to gas,P2G)系统中电解水和甲烷化两阶段产出的氢气和甲烷可促进综合能源系统(integratedenergysystem,IES)消纳盈余可再生能源。传统P2G系统只考虑将甲烷作为燃气机组的燃料,未充分利用氢气高电解率的特性,造成能量梯级转化次数增加,能量损耗提高。应用P2G系统两阶段分别产出的氢气和甲烷耦合气网注氢(hydrogen injection into gas grid,HIGG)技术以促进IES中可再生能源的消纳。基于能量枢纽的概念,将IES系统经济性优化调度转化为混合整数规划问题进行求解。通过两个场景的仿真分析说明,相比于仅应用甲烷的传统P2G系统,IES系统中应用P2G和HIGG技术能够降低部分能量梯级转化次数和成本投入,在经济性、环保性方面都有显著提高。