期刊文献+
共找到702篇文章
< 1 2 36 >
每页显示 20 50 100
Research on power electronic transformer applied in AC/DC hybrid distribution networks 被引量:15
1
作者 Yiqun Miao Jieying Song +6 位作者 Haijun Liu Zhengang Lu Shufan Chen Chun Ding Tianzhi Cao Linhai Cai Yuzhong Gong 《Global Energy Interconnection》 2018年第3期396-403,共8页
The AC/DC hybrid distribution network is one of the trends in distribution network development, which poses great challenges to the traditional distribution transformer. In this paper, a new topology suitable for AC/D... The AC/DC hybrid distribution network is one of the trends in distribution network development, which poses great challenges to the traditional distribution transformer. In this paper, a new topology suitable for AC/DC hybrid distribution network is put forward according to the demands of power grid, with advantages of accepting DG and DC loads, while clearing DC fault by blocking the clamping double sub-module(CDSM) of input stage. Then, this paper shows the typical structure of AC/DC distribution network that is hand in hand. Based on the new topology, this paper designs the control and modulation strategies of each stage, where the outer loop controller of input stage is emphasized for its twocontrol mode. At last, the rationality of new topology and the validity of control strategies are verified by the steady and dynamic state simulation. At the same time, the simulation results highlight the role of PET in energy regulation. 展开更多
关键词 AC/DC hybrid distribution network power electronic transformer(PET) Clamping double sub-module(CDSM) Energy router
在线阅读 下载PDF
A Discrete State Event Driven Simulation based Losses Analysis for Multi-terminal Megawatt Power Electronic Transformer 被引量:6
2
作者 Jialin Zheng Zhengming Zhao +3 位作者 Bochen Shi Zhujun Yu Jiahe Ju Zhiqiang Fan 《CES Transactions on Electrical Machines and Systems》 CSCD 2020年第4期275-284,共10页
At present,power electronic transformers(PETs)have been widely used in power systems.With the increase of PET capacity to the megawatt level.the problem of increased losses need to be taken seriously.As an important i... At present,power electronic transformers(PETs)have been widely used in power systems.With the increase of PET capacity to the megawatt level.the problem of increased losses need to be taken seriously.As an important indicator of power electronic device designing,losses have always been the focus of attention.At present,the losses are generally measured through experiments,but it takes a lot of time and is difficult to quantitatively analyze the internal distribution of PET losses.To solve the above problems,this article first qualitatively analyzes the losses of power electronic devices and proposes a loss calculation method based on pure simulation.This method uses the Discrete State Event Driven(DSED)modeling method to solve the problem of slow simulation speed of large-capacity power electronic devices and uses a loss calculation method that considers the operating conditions of the device to improve the calculation accuracy.For the PET prototype in this article,a losses model of the PET is established.The comparison of experimental and simulation results verifies the feasibility of the losses model.Then the losses composition of PET was analyzed to provide reference opinions for actual operation.It can help pre-analyze the losses distribution of PET,thereby providing a potential method for improving system efficiency. 展开更多
关键词 power electronic transformer(PET) losses analysis efficiency losses branch model discrete-state event-driven
在线阅读 下载PDF
Structured Microgrids (SμGs) and Flexible Electronic Large Power Transformers (FeLPTs) 被引量:4
3
作者 Don Tan 《CES Transactions on Electrical Machines and Systems》 CSCD 2020年第4期255-263,共9页
Structured microgrids(SμGs)and Flexible electronic large power transformers(FeLPTs)are emerging as two essential technologies for renewable energy integration,flexible power transmission,and active control.SμGs prov... Structured microgrids(SμGs)and Flexible electronic large power transformers(FeLPTs)are emerging as two essential technologies for renewable energy integration,flexible power transmission,and active control.SμGs provide the integration of renewable energy and storage to balance the energy demand and supply as needed for a given system design.FeLPT’s flexibility for processing,control,and re-configurability offers the capability for flexible transmission for effective flow control and enable SμGs connectivity while still keeping multiscale system level control.Early adaptors for combined heat and power have demonstrated significant economic benefits while reducing environmental foot prints.They bring tremendous benefits to utility companies also.With storage and active control capabilities,a 300-percent increase in bulk transmission and distribution lines are possible without having to increase capacity.SμGs and FeLPTs will also enable the utility industry to be better prepared for the emerging large increase in base load demand from electric transportation and data centers.This is a win-win-win situation for the consumer,the utilities(grid operators),and the environment.SμGs and FeLPTs provide value in power substation,energy surety,reliability,resiliency,and security.It is also shown that the initial cost associated with SμG and FeLPTs deployment can be easily offset with reduced operating cost,which in turn reduces the total life-cycle cost by 33%to 67%. 展开更多
关键词 Terms-Structured microgrids flexible electronic large power transformers energy systems renewable integration grid modernization active control life-cycle cost
在线阅读 下载PDF
New Progress of Power Electronic On-Load Tap Changing Distributing Transformer
4
作者 ZHANG Pinxiu ZHAO Yulin 《Journal of Northeast Agricultural University(English Edition)》 CAS 2009年第1期64-68,共5页
At present, the widely applied mechanical on-load tap-changer is not suitable for the 10 kV power distribution network. Along with the development of power electronic technology, there has the report on on-load tap ch... At present, the widely applied mechanical on-load tap-changer is not suitable for the 10 kV power distribution network. Along with the development of power electronic technology, there has the report on on-load tap changing (OLTC) distributing transformer based on the power electronic technology. In this paper, the analysis on the characteristic of several kinds of non-contacts OLTC distributing transformer was carried on. The result indicates that OLTC distributing transformer based on the solid state relay has the broad applied prospect in the 10 kV medium distribution network. 展开更多
关键词 powers electronics non-contact OLTC transformeR SSR
在线阅读 下载PDF
Optical fiber-based power and data delivery system for high voltage electronic current transformer
5
作者 邱红辉 段雄英 邹积岩 《Journal of Shanghai University(English Edition)》 CAS 2008年第3期268-273,共6页
This paper describes a prototype power delivery system developed for high voltage electronic current transformer (ECT) that uses laser light to transfer power to and communicates with the primary converter. The desi... This paper describes a prototype power delivery system developed for high voltage electronic current transformer (ECT) that uses laser light to transfer power to and communicates with the primary converter. The design is based on optical-to-electrical power converters, solid-state diode lasers and optical fibers. Command signals are transmitted via the same up-fiber used to send power from secondary power supply to primary converter. The upward data transmission is completed during the brief interruption of power delivery without affecting steady power-supply. A simple comparator added to the primary converter can take the command data. Experimental results show that the fibers can provide reliable up-link for data transmission at 200 kb/s from the secondary to the primary converter. Based on the delivery system, the secondary converter can control three auxiliary channels to provide additional information. These monitoring channels are used in a time-multiplexing mode to provide information about the operation temperature, voltage and current at the remote unit for monitoring the ECT. This preventive maintenance or built-in test can increase reliability by giving early warning for necessary maintenance request. 展开更多
关键词 high voltage electronic current transformer (ECT) optical power supply delivery system photovoltaic powerconverters supervisory functions
在线阅读 下载PDF
Dual-Timescale Control for Power Electronic Zigzag Transformer 被引量:1
6
作者 Chunpeng Zhang Zhengming Zhao 《CES Transactions on Electrical Machines and Systems》 2017年第3期315-321,共7页
Power electronic zigzag transformer is an attractive solution for the flexible interconnection of smart distribution networks.It is constituted by slow-response and low-precision thyristor converters and fast-response... Power electronic zigzag transformer is an attractive solution for the flexible interconnection of smart distribution networks.It is constituted by slow-response and low-precision thyristor converters and fast-response and high-accuracy voltage source converters.This paper models its primary circuit and addresses its basic operation mechanism.Then a dual-timescale control scheme is investigated to realize the coordinated regulation of both types of converter.A simulation case is established in PSCAD containing interconnected mid-voltage distribution networks.Simulations with poor-and well-matched control timescales are both carried out.And accordingly,the power flow controllability under these conditions is compared.When the shorter control timescale is no more than tenth of the longer one,the power electronic zigzag transformer will operate with satisfying performances. 展开更多
关键词 power electronic transformer thyristor converter voltage source converter dual-timescale control flexible interconnection
在线阅读 下载PDF
Design of Transformer Magnetic Bias Protection Device in High Power Electronic Equipments
7
作者 Xi Lei Guizhi Xu Zhanfeng Deng 《Journal of Electrical Engineering》 2014年第2期75-81,共7页
As the power electronics technology is widely used in the power system, it may also bring the DC component to the transformer operation, resulting in DC bias and may cause great harm to the transformer. In this articl... As the power electronics technology is widely used in the power system, it may also bring the DC component to the transformer operation, resulting in DC bias and may cause great harm to the transformer. In this article, the device to protect transformer from DC magnetic bias is designed. On the basis of load DC current, a magnetic bias protection device is developed by combination of current sensor, electric information collection circuit, signal filtering circuit, signal modulating circuits, fault feature judging circuit, automatic range tracking circuit, intelligent logic synthesis unit and implementation output circuit. By operating in temperature-rise test equipment in the high power electronic lab, the device is proved with reliability, high sensitivity and worthy of promotion and application. 展开更多
关键词 power electronic device transformeR magnetic bias PROTECTION design.
在线阅读 下载PDF
Unbalanced Load Simulation of Electronic Power Transformer in Distribution System
8
作者 Wang Dan Mao Chengxiong +3 位作者 Lu Jiming Fan Shu Cao Jiewei Wang Ben(Translated) 《Electricity》 2006年第1期38-43,共6页
A control scheme of electronic power transformer (EPT) in a three-phase four-wire distribution system, which included an input section, an isolating section and an output section, was researched under unbalanced loads... A control scheme of electronic power transformer (EPT) in a three-phase four-wire distribution system, which included an input section, an isolating section and an output section, was researched under unbalanced loads. The simple and appropriate control scheme was developed through analyzing the system requirements of the primary side and the load requirements of the secondary side. In the input section, a dual-loop control in synchronous rotating d-q coordinates was introduced, and in the output section, a dual-loop control based on instantaneous output voltage was used. Load characteristics of EPT were investigated by using Matlab/Simulink software. Simulation results showed that, with the proposed control scheme, the EPT has good performances and the sinusoidal input current and constant output voltage can be realized under both balanced and unbalanced loads. 展开更多
关键词 electronic power transformer distribution system unbalanced load
在线阅读 下载PDF
Voltage Profile Enhancement and Power Loss Reduction with Economic Feasibility Using Small Capacity Distribution Transformers 被引量:1
9
作者 Rasool M.Imran Mohammed R.Saeed +5 位作者 Mohammed Amer Mohammed Osama A.Suhry Ihsan H.Abdulqadder Hasan Wahhab Salih Mohammed R.Almallah Firas M.F.Flaih 《Energy Engineering》 EI 2022年第6期2447-2467,共21页
Usually,rural areas can be electrified via three-phase distribution transformers with relatively large capacities.In such areas,low voltage lines are used for long distances,which cause power losses and voltage drop f... Usually,rural areas can be electrified via three-phase distribution transformers with relatively large capacities.In such areas,low voltage lines are used for long distances,which cause power losses and voltage drop for different types of consumers.Reducing losses and improving voltage profiles in rural distribution networks are significant challenges for electricity distribution companies.However different solutions were proposed in the literature to overcome these challenges,most of them face difficulties when applied in the conventional distribution network.To address the above issues,an applicable solution is proposed in this paper by installing a number of small-capacity distribution transformers instead of every single large-capacity transformer in rural areas.The proposed approach is implemented in the branch network of Al-Hoqool village,which belongs to the Nineveh distribution network.The network has been inspected on-site,drawn,and analyzed using the electrical systems analysis program(ETAP).The analysis showed that using the single-phase pole-mounted transformers can improve the voltage in the network’s end by 29%and enhance the voltage profile for all consumers.The analysis has also demonstrated that the modification can reduce the total power losses by 78%compared to the existing network.Concerning the economic aspect,the payback period for the proposed network is assigned to be 20 months. 展开更多
关键词 single-phase pole-mounted transformer three-phase transformer power losses voltage profile distribution networks
在线阅读 下载PDF
High Voltage High Frequency Power Transformer for Pulsed Power Applications 被引量:2
10
作者 T. Filchev A. Watson J. Clare P. Wheeler F. Carastro 《Journal of Energy and Power Engineering》 2011年第10期960-965,共6页
This paper presents a new topology for a High Voltage (HV) 50 kV, High Frequency (HF) 20 kHz, multi-cored transformer suitable for use in pulsed power application systems. The main requirements are: high voltage ... This paper presents a new topology for a High Voltage (HV) 50 kV, High Frequency (HF) 20 kHz, multi-cored transformer suitable for use in pulsed power application systems. The main requirements are: high voltage capability, small size and weight. The HV, HF transformer is the main critical block of a high frequency power converter system. The transformer must have high electrical efficiency and in the proposed approach has to be optimized by the number of the cores. The transformer concept has been investigated analytically and through software simulations and experiments. This paper introduces the transformer topology and discusses the design procedure. Experimental measurements to predict core losses are also presented. The losses of epoxy coated nanocrystalline are compared to the losses in a new uncoated core. 展开更多
关键词 transformeR nanocrystalline soft magnetic material power electronics pulsed power.
在线阅读 下载PDF
Low-voltage ride through of multi-port power electronic trans-former
11
作者 Wusong Wen Zhengming Zhao +1 位作者 Shiqi Ji Liqiang Yuan 《iEnergy》 2022年第2期243-256,共14页
A low-voltage ride-through(LVRT)control strategy for the multi-port power electronic transformer(PET)based on power co-regulation is proposed.During the sag and recovery of the grid-side voltage of the medium-voltage ... A low-voltage ride-through(LVRT)control strategy for the multi-port power electronic transformer(PET)based on power co-regulation is proposed.During the sag and recovery of the grid-side voltage of the medium-voltage ac(MVac)port,the grid-connected active power of the low-voltage ac(LVac)port,rather than the power from external renewable energy sources(e.g.,photovoltaic(PV)),is adjusted quickly to rebalance the power flowing across all ports,thereby preventing overcurrent and overvoltage.Moreover,a power-coordinate-frame-based LVRT mode classification is designed,and a total of six LVRT modes are classified to meet the LVRT requirements in all power configuration scenarios of the PET.In this way,the PET is endowed with the LVRT capability in both power-generation and power-consumption states,which is significantly different from traditional power generation systems such as PV or wind power.Furthermore,by optimizing the active power regulation path during LVRT transition,the overcurrent problem caused by the grid-voltage sag-depth detection delay is overcome.Finally,the effectiveness of the proposed control scheme is verified by experiments on a hardware-in-the-loop platform. 展开更多
关键词 Active-power regulation path optimization low-voltage ride through(LVRT) LVRT mode classification power electronic transformer(PET)
在线阅读 下载PDF
Low-Frequency Stability Analysis of Power Electronic Traction Transformer Based Train-Network System 被引量:1
12
作者 Yi Hong Yang Li +1 位作者 Zhikang Shuai Hanyu Yang 《CSEE Journal of Power and Energy Systems》 SCIE EI CSCD 2024年第4期1608-1617,共10页
Power electronic traction transformers(PETTs)will be increasingly applied to locomotives in the future for their small volume and light weight.However,similar to conventional trains,PETTs behave as constant power load... Power electronic traction transformers(PETTs)will be increasingly applied to locomotives in the future for their small volume and light weight.However,similar to conventional trains,PETTs behave as constant power loads and may cause low-frequency oscillation(LFO)to the train-network system.To solve this issue,a mathematical model of the PETT is firstly proposed and verified based on the extended describing function(EDF)method in this paper.In the proposed model,the LLC converter is simplified to an equivalent circuit consisting of a capacitor and a resistor in parallel.It is further demonstrated that the model can apply to various LLC converters with different topologies and controls.Particularly,when the parameter differences between cells are not obvious,the PETT can be simplified to a single-phase rectifier(i.e.,conventional train)by equivalent transformation.Based on the model of PETT,the system low-frequency stability and influential factors are analyzed by using the generalized Nyquist criterion.Lastly,the correctness and accuracy of theoretical analyses are validated by off-line and hardware-in-the-loop simulation results. 展开更多
关键词 Extended describing function method impedance model low-frequency oscillation power electronic traction transformer train-network system
原文传递
Towards a (More) Electronic Transmission and Distribution (eT&D)
13
作者 Don Tan Damir Novosel 《CES Transactions on Electrical Machines and Systems》 2017年第1期15-25,共11页
The challenges and the path towards a(more)electronic transmission and distribution(eT&D)is presented in this paper.The challenges are first identified together with key stakeholders in the drive for grid moderniz... The challenges and the path towards a(more)electronic transmission and distribution(eT&D)is presented in this paper.The challenges are first identified together with key stakeholders in the drive for grid modernization.A fundamental question is then asked about the investment priority.Six basic characteristics are reviewed,leading to the composition of structured microgrids as the basic functional cell of a modern grid.One example of fractal radial structure and one fractal meshed structure are presented.The likely evolution path is then proposed together with basic technology sets.Specific foundation technologies are discussed in detail,including adiabatic power conversion,3MC technology,medium voltage conversion,distribution-level electronic power transformer and FACTs hardware integration,and back-to-back converters as a universal interconnect element.The rapidly emerging on-wire sensing technology is also discussed.It is pointed out that the distribution-level large electronic power transformer will provide a key component to enable hybrid ac/dc grid flow control and ancillary support for a flexible electronic transmission and distribution(eT&D)systems. 展开更多
关键词 All things grid connected electric power systems electronic transmission&distribution(eT&D) energy solutions flexible electronic transmission systems(FETS) grid modernization large electronic power transformers 3MC converters renewable energy.
在线阅读 下载PDF
Power electronic transformer with adaptive PLL technique for voltage-disturbance ride through 被引量:7
14
作者 Jianhua WANG Fangfang LUO +5 位作者 Qing DUAN Zhendong JI Binshi GU Jun YOU Wei GU Jianfeng ZHAO 《Journal of Modern Power Systems and Clean Energy》 SCIE EI 2018年第5期1090-1102,共13页
The power electronic transformer(PET) has recently emerged as a type of power converter. It features the basic functions of power conversion and isolation as well as additional functions related to power quality contr... The power electronic transformer(PET) has recently emerged as a type of power converter. It features the basic functions of power conversion and isolation as well as additional functions related to power quality control. A novel PET for a distribution grid called a flexible power distribution unit is proposed in this paper, and the energy exchange mechanism between the network and the load is revealed. A 30 kW 600 VAC/220 VAC/110 VDC medium-frequency isolated prototype is developed and demonstrated. This paper also presents key control strategies of the PET for electrical distribution grid applications,especially under grid voltage disturbance conditions.Moreover, stability issues related to the grid-connected three-phase PET are discussed and verified with an impedance-based analysis. The PET prototype is tested, and it passes the voltage-disturbance ride-through function. The experimental results verify the power quality control abilities of the PET. 展开更多
关键词 power electronic transformer Mediumfrequency isolation Voltage-disturbance RIDE THROUGH power quality Stability
原文传递
A Three-phase Integrated Power Electronic Transformer with the Capability of DC Fault Clearance 被引量:5
15
作者 Yunfei Xu Guangfu Tang +2 位作者 Weiguo Li Guoliang Zhao Zhanfeng Deng 《CSEE Journal of Power and Energy Systems》 SCIE CSCD 2021年第4期785-796,共12页
This paper presents a three-phase integrated power electronic transformer(PET)topology with the capability of DC fault clearance based on the investigation of PET topology.The proposed PET has three ports of high-volt... This paper presents a three-phase integrated power electronic transformer(PET)topology with the capability of DC fault clearance based on the investigation of PET topology.The proposed PET has three ports of high-voltage AC,high-voltage DC and low-voltage DC,which can achieve the flexible access of distributed energy resources・The power unit of the PET adopts a three-phase integrated topology,and the single-phase fluctuating power in the DC-link capacitor is reduced by a 4-port DC/DC converter,thereby reducing the capacitance of the DC-link capacitor;Meanwhile,the power unit uses the clamp double sub-module(CDSM)to allow for self-clearing of the short-circuit fault on the high-voltage DC side.Finally,this paper verifies the proposed PET through an EMT simulation and experimental prototype. 展开更多
关键词 DC fault clearing experimental verification power electronic transformer three phase integration
原文传递
A novel low voltage ride through strategy for cascaded power electronic transformer 被引量:13
16
作者 Jiexiang Han Xiangping Kong +2 位作者 Peng Li Zhe Zhang Xianggen Yin 《Protection and Control of Modern Power Systems》 2019年第1期239-250,共12页
In view of the operating characteristics for voltage sags of AC side of the power electronic transformer(PET),a low-voltage ride through(LVRT)strategy adapted to bidirectional power exchange of PET is proposed for the... In view of the operating characteristics for voltage sags of AC side of the power electronic transformer(PET),a low-voltage ride through(LVRT)strategy adapted to bidirectional power exchange of PET is proposed for the purposes of maintaining the system stability,assisting the system voltage recovery and protecting PET safety.During the asymmetric voltage sag,the negative sequence current of PET is eliminated to ensure the symmetry of the injected current.According to the degree of positive sequence voltage sag,the reactive current injection is provided to assist in voltage recovery.According to the PET active power condition before the voltage sag,the level and direction of which are maintained as far as possible without exceeding the limit,for which the disturbance to the AC and DC grids is reduced.Finally,the effectiveness of the proposed LVRT strategy is verified by simulation model. 展开更多
关键词 power electronic transformer Low-voltage ride through Control strategy Current instruction value
原文传递
A Critical Topology Review of Power Electronic Transformers:In View of Efficiency 被引量:5
17
作者 Guidong Zhang Jie Chen +1 位作者 Bo Zhang Yun Zhang 《Chinese Journal of Electrical Engineering》 CSCD 2018年第2期90-95,共6页
Design of power electronic transformers is a hot research topic and its efficiency improvement is a critical problem all over the world.It is also the largest barrier hindering the application of power electronic tran... Design of power electronic transformers is a hot research topic and its efficiency improvement is a critical problem all over the world.It is also the largest barrier hindering the application of power electronic transformers in industry.In this paper,the state of power electronic transformers is fully presented in terms of efficiency improvements.It is followed by the efficiency modeling of several typical topologies,and their detailed analysis and comparisons.Then,the corresponding industrial application scope of these topologies is presented,providing theoretical guidance for their industrial applications. 展开更多
关键词 power electronic transformer TOPOLOGY EFFICIENCY MODELING
原文传递
考虑波动功率耦合的电力电子变压器电容电压纹波抑制方法研究
18
作者 牛春豪 徐永海 《电测与仪表》 北大核心 2025年第1期208-216,共9页
级联型电力电子变压器通常采用大电容来抑制子模块的电容电压波动,这严重限制了电力电子变压器功率密度的提高。针对这一问题,文中首先推导了二倍频波动电压的产生机理和波动功率的耦合原理,然后从输入阻抗的角度对波动功率不能自然流... 级联型电力电子变压器通常采用大电容来抑制子模块的电容电压波动,这严重限制了电力电子变压器功率密度的提高。针对这一问题,文中首先推导了二倍频波动电压的产生机理和波动功率的耦合原理,然后从输入阻抗的角度对波动功率不能自然流入后级的原因进行了分析,进而提出了一种实时调整隔离级输入电流的电容电压纹波抑制策略,有效地降低了电容电压波动幅值,最后在PSCAD/EMTDC中搭建仿真模型,并与传统控制策略进行对比,验证了所提策略的有效性。 展开更多
关键词 波动功率耦合 级联型电力电子变压器 纹波抑制 电容优化
在线阅读 下载PDF
基于端口功率协调的双电源输入PET暂降耐受能力提升方法
19
作者 张腾飞 王光华 +3 位作者 高龙 李静 徐永海 王冲 《电力工程技术》 北大核心 2025年第1期92-103,共12页
双电源输入级联型电力电子变压器(dual power supply cascaded-type power electronic transformer,DPSC-PET)与两路供电电源相连,运行可靠性高、方式灵活,在中低压配电网中应用前景广泛,深入研究其电压暂降耐受能力与调节方法,对于维... 双电源输入级联型电力电子变压器(dual power supply cascaded-type power electronic transformer,DPSC-PET)与两路供电电源相连,运行可靠性高、方式灵活,在中低压配电网中应用前景广泛,深入研究其电压暂降耐受能力与调节方法,对于维持暂降期间DPSC-PET的高效能量传输、保证系统优质供电具有重要意义。首先,分析DPSC-PET的拓扑与控制策略;其次,针对引起系统传输功率缺额最严重的三相对称电压暂降,分析DPSC-PET暂降耐受能力限制因素;然后,从功率平衡角度出发,提出一种不同输入侧发生暂降时DPSC-PET耐受能力实时分析与双输入端口功率协同调节方法,以实现暂降下低压直流母线电压恢复,提升DPSC-PET应对暂态扰动的能力;最后,搭建DPSC-PET仿真模型,对不同输入侧发生不同程度的电压暂降场景进行仿真。结果表明,所提调节方法能有效提升DPSC-PET的暂降耐受能力。 展开更多
关键词 双电源输入 电力电子变压器(PET) 电压暂降 耐受能力 直流母线电压 功率平衡
在线阅读 下载PDF
含源电网中复合储能式电子变压器声纹机械的协调控制
20
作者 吴海涵 李俊妮 +2 位作者 王维佳 孙飞 宋彦 《储能科学与技术》 北大核心 2025年第2期714-716,共3页
随着电网技术的不断发展,含源电网中复合储能式电力电子变压器的应用日益广泛。然而,在实际运行中,储能式电力电子变压器面临着电网电压跌落或中断等挑战,这对其稳定性和电能质量提出了更高要求。本文综述了基于声纹识别的变压器协调控... 随着电网技术的不断发展,含源电网中复合储能式电力电子变压器的应用日益广泛。然而,在实际运行中,储能式电力电子变压器面临着电网电压跌落或中断等挑战,这对其稳定性和电能质量提出了更高要求。本文综述了基于声纹识别的变压器协调控制以及监控策略,首先分析了复合储能式电子变压器的原理结构组成以及当前环境下的技术特征;然后以此为基础,进一步探讨了声纹识别技术在储能电子变压器的应用实况,最后综述了声纹识别技术下的变压器协调控制与监控策略。希望可以为后续研究提供一定理论借鉴。 展开更多
关键词 含源电网 复合储能式电力电子变压器 声纹识别 协调控制
在线阅读 下载PDF