期刊文献+
共找到368篇文章
< 1 2 19 >
每页显示 20 50 100
Cerebral functional imaging of Waiguan (SJ 5) acupoint specificity using single-photon emission computed tomography 被引量:2
1
作者 Yong Huang Yangjia Lu +5 位作者 Ganlong Li Xinsheng Lai Hong Zhang Chunzhi Tang JunjunYang Gustav Wik 《Neural Regeneration Research》 SCIE CAS CSCD 2011年第6期428-434,共7页
The action of needling in acupoint therapy has to first be regulated and integrated by the brain, and then it affects the target organ and manifests its therapeutic effects, which is dependent on the specificity of th... The action of needling in acupoint therapy has to first be regulated and integrated by the brain, and then it affects the target organ and manifests its therapeutic effects, which is dependent on the specificity of the acupoints. The authors put forward the hypothesis of the "acupoint-related brain". Single-photon emission computed tomography was used to explore the activation of brain regions following true needling in true acupoint Waiguan (SJ 5), sham needling in true acupoint Waiguan, true needling in a sham point, and sham needling in a sham point. The relative specificity of Waiguan in normal persons was analyzed by observing changes in regional cerebral blood flow. Compared with the sham needling in true acupoint group and sham needling in the sham point group, acupuncture at Waiguan can activate brain regions controlling movement. Compared with true needling in the sham point group, acupuncture at Waiguan can also activate brain regions controlling movement. The results suggest that the specificity of needling at an acupoint is related to certain activated cerebral functional regions, which are associated with the clinical application of the acupoint. 展开更多
关键词 acupoint specificity Waiguan (SJ 5) NEEDLING sham needling sham point single-photon emission computed tomography
在线阅读 下载PDF
Indocyanine green plasma clearance rate and 99mTc-galactosyl human serum albumin single-photon emission computed tomography evaluated preoperative remnant liver
2
作者 Kentaro Iwaki Satoshi Kaihara +3 位作者 Ryosuke Kita Koji Kitamura Hiroki Hashida Kenji Uryuhara 《World Journal of Clinical Cases》 SCIE 2022年第25期8844-8853,共10页
BACKGROUND Preoperative evaluation of future remnant liver reserves is important for safe hepatectomy.If the remnant is small,preoperative portal vein embolization(PVE)is useful.Liver volume analysis has been the prim... BACKGROUND Preoperative evaluation of future remnant liver reserves is important for safe hepatectomy.If the remnant is small,preoperative portal vein embolization(PVE)is useful.Liver volume analysis has been the primary method of preoperative evaluation,although functional examination may be more accurate.We have used the functional evaluation liver using the indocyanine green plasma clearance rate(KICG)and 99mTc-galactosyl human serum albumin single-photon emission computed tomography(99mTc-GSA SPECT)for safe hepatectomy.AIM To analyze the safety of our institution’s system for evaluating the remnant liver reserve.METHODS We retrospectively reviewed the records of 23 patients who underwent preoperative PVE.Two types of remnant liver KICG were defined as follows:Anatomical volume remnant KICG(a-rem-KICG),determined as the remnant liver anatomical volume rate×KICG;and functional volume remnant KICG(frem-KICG),determined as the remnant liver functional volume rate based on 99mTc-GSA SPECT×KICG.If either of the remnant liver KICGs were>0.05,a hepatectomy was performed.Perioperative factors were analyzed.We defined the marginal group as patients with a-rem-KICG of<0.05 and a f-rem-KICG of>0.05 and compared the postoperative outcomes between the marginal and not marginal(both a-rem-KICG and f-rem-KICG>0.05)groups.RESULTS All 23 patients underwent planned hepatectomies.Right hepatectomy,right trisectionectomy and left trisectionectomy were in 16,6 and 1 cases,respectively.The mean of blood loss and operative time were 576 mL and 474 min,respectively.The increased amount of frem-KICG was significantly larger than that of a-rem-KICG after PVE(0.034 vs 0.012,P=0.0273).The not marginal and marginal groups had 17(73.9%)and 6(26.1%)patients,respectively.The complications of Clavian-Dindo classification grade II or higher and post-hepatectomy liver failure were observed in six(26.1%)and one(grade A,4.3%)patient,respectively.The 90-d mortality was zero.The marginal group had no significant difference in postoperative outcomes(prothrombin time/international normalised ratio,total bilirubin,complication,post-hepatectomy liver failure,hospital stay,90-d,and mortality)compared with the not-marginal group.CONCLUSION Functional evaluation of the remnant liver enabled safe hepatectomy and may extend the indication for hepatectomy after PVE treatment. 展开更多
关键词 99mTc-galactosyl human serum albumin single-photon emission computed tomography HEPATEctOMY Indocyanine green Indocyanine green plasma clearance rate Liver function evaluation Remnant liver reserve
在线阅读 下载PDF
Rest Thallium-201/Stress Technetium-99m Sestamibi Dual-Isotope Myocardial Perfusion Single-Photon Emission Computed Tomography in Detecting of Chronic Coronary Artery Disease
3
作者 Phuong Kim Huynh Lap Vu Cong +1 位作者 Xuan Quang Truong Canh Nguyen Xuan 《Journal of Pharmacy and Pharmacology》 2016年第5期183-191,共9页
To investigate diagnostic accuracy of 2-hour protocol of rest thallium-201/stress technetium-99m sestamibi dual-isotope myocardial perfusion SPECT in chronic coronary artery disease. Sixty-seven patients with suspecte... To investigate diagnostic accuracy of 2-hour protocol of rest thallium-201/stress technetium-99m sestamibi dual-isotope myocardial perfusion SPECT in chronic coronary artery disease. Sixty-seven patients with suspected CAD were enrolled in the prospective study. All patients underwent myocardial perfusion scintigraphy in SPECT with dual isotopes of T1-201 and dipyridamole stress Tc-99m sestamibi. Rest and stress imaging protocol were performed in 2 hours by dose of 3 mCi TI-201 and 25 mCi Tc-99m sestamibi. The acquisition parameters includes LEHR collimator, energy peak of 72 and 167 keV for T1-201 and 140 keV for Tc-99m, 180-degree rotation from RAO to LPO, matrix size 64x64, and 25second/frame/64 frames. The 20-segment model of left ventricle was used in automatic quantitation software. Coronary angiography was used as gold standard. CAD was defined as 50% of lumen stenosis on coronary angiography. Rest TI-201/stress tc-99m sestamibi dual-isotope SPECT demonstrated a sensitivity of 94.59% and specificity of 70%, positive predictive value of 79.54% and negative predictive value of 91.3% in detection of coronary artery disease. Sensitivity and specificity for detecting multi-vessel coronary artery disease were 82.75% and 81.57% for the left anterior descending, 77.77% and 91.83% for left circumflex and 94.11% and 82% for right coronary artery. 2-hour protocol of rest thallium-201/stress technetium-99m sestamibi dual-isotope myocardial perfusion SPECT has high sensitivity, specificity, positive predictive value and negative predictive value in detecting chronic coronary artery disease with greater than 50% stenosis assessed by coronary angiography Moreover, this imaging protocol gives high imaging quality, time-saving and convenience. 展开更多
关键词 MPS (myocardial perfusion scintigarphy) spect (single proton emission computed tomography CAD (coronary arterydisease) CA (coronary angiography).
在线阅读 下载PDF
Hepatic clearance measured with ^(99m)Tc-GSA single-photon emission computed tomography to estimate liver fibrosis 被引量:13
4
作者 Masahiko Taniguchi Atsutaka Okizaki +6 位作者 Kenji Watanabe Koji Imai Koichiro Uchida Takahiro Einama Noriyuki Shuke Naoyuki Miyokawa Hiroyuki Furukawa 《World Journal of Gastroenterology》 SCIE CAS 2014年第44期16714-16720,共7页
AIM: To evaluate the clinical utility of hepatic clearance(HC) measured with technetium-99m-diethylenetriaminepenta-acetic acid-galactosyl human serum albumin(99mTc-GSA) single-photon emission computed tomography(SPEC... AIM: To evaluate the clinical utility of hepatic clearance(HC) measured with technetium-99m-diethylenetriaminepenta-acetic acid-galactosyl human serum albumin(99mTc-GSA) single-photon emission computed tomography(SPECT) to estimate the degree of liver fibrosis.METHODS:Seventy-eight consecutive patients who underwent initial hepatectomy due to hepatocellular carcinoma were enrolled in this study.Indocyanine green clearance(ICG R15),quantitative indices estimated by 99mTc-GSA[the receptor index(LHL15 and HH15)and HC via SPECT analysis],and conventional liver function tests were performed before hepatectomy.Correlations among the quantitative indices for liver functional reserve,conventional liver function tests,andthe degree of liver fibrosis were evaluated.RESULTS:The degree of liver fibrosis was correlated with ICG R15,HH15,LHL15,and HC.HC showed the best correlation with conventional liver function tests.According to multivariate analysis,HC and LHL15 were significant independent predictors of severe fibrosis.HC was the most valuable index for predicting severe fibrosis.CONCLUSION:HC measured with 99mTc-GSA SPECT is a reliable index for assessing liver fibrosis before hepatectomy. 展开更多
关键词 FIBROSIS Technetium-99m-diethylenetri-aminepenta-acetic acid-galactosyl human serum albu-min single-photon emission computed tomography Hepatic clearance Liver resection
在线阅读 下载PDF
Significance of functional hepatic resection rate calculated using 3D CT/^(99m)Tc-galactosyl human serum albumin singlephoton emission computed tomography fusion imaging 被引量:6
5
作者 Yosuke Tsuruga Toshiya Kamiyama +6 位作者 Hirofumi Kamachi Shingo Shimada Kenji Wakayama Tatsuya Orimo Tatsuhiko Kakisaka Hideki Yokoo Akinobu Taketomi 《World Journal of Gastroenterology》 SCIE CAS 2016年第17期4373-4379,共7页
AIM: To evaluate the usefulness of the functional hepatic resection rate (FHRR) calculated using 3D computed tomography (CT)/<sup>99m</sup>Tc-galactosyl-human serum albumin (GSA) single-photon emission com... AIM: To evaluate the usefulness of the functional hepatic resection rate (FHRR) calculated using 3D computed tomography (CT)/<sup>99m</sup>Tc-galactosyl-human serum albumin (GSA) single-photon emission computed tomography (SPECT) fusion imaging for surgical decision making.METHODS: We enrolled 57 patients who underwent bi- or trisectionectomy at our institution between October 2013 and March 2015. Of these, 26 patients presented with hepatocellular carcinoma, 12 with hilar cholangiocarcinoma, six with intrahepatic cholangiocarcinoma, four with liver metastasis, and nine with other diseases. All patients preoperatively underwent three-phase dynamic multidetector CT and <sup>99m</sup>Tc-GSA scintigraphy. We compared the parenchymal hepatic resection rate (PHRR) with the FHRR, which was defined as the resection volume counts per total liver volume counts on 3D CT/<sup>99m</sup>Tc-GSA SPECT fusion images.RESULTS: In total, 50 patients underwent bisectionectomy and seven underwent trisectionectomy. Biliary reconstruction was performed in 15 patients, including hepatopancreatoduodenectomy in two. FHRR and PHRR were 38.6 &#x000b1; 19.9 and 44.5 &#x000b1; 16.0, respectively; FHRR was strongly correlated with PHRR. The regression coefficient for FHRR on PHRR was 1.16 (P &#x0003c; 0.0001). The ratio of FHRR to PHRR for patients with preoperative therapies (transcatheter arterial chemoembolization, radiation, radiofrequency ablation, etc.), large tumors with a volume of &#x0003e; 1000 mL, and/or macroscopic vascular invasion was significantly smaller than that for patients without these factors (0.73 &#x000b1; 0.19 vs 0.82 &#x000b1; 0.18, P &#x0003c; 0.05). Postoperative hyperbilirubinemia was observed in six patients. Major morbidities (Clavien-Dindo grade &#x02265; 3) occurred in 17 patients (29.8%). There was no case of surgery-related death.CONCLUSION: Our results suggest that FHRR is an important deciding factor for major hepatectomy, because FHRR and PHRR may be discrepant owing to insufficient hepatic inflow and congestion in patients with preoperative therapies, macroscopic vascular invasion, and/or a tumor volume of &#x0003e; 1000 mL. 展开更多
关键词 99mTc-galactosyl human serum albumin single-photon emission computed tomography HEPATEctOMY Functional hepatic resection rate Parenchymal hepatic resection rate
在线阅读 下载PDF
Qualitative visual trichotomous assessment improves the value of fluorine-18 fluorodeoxyglucose positron emission tomography/computed tomography in predicting the prognosis of diffuse large B-cell lymphoma 被引量:1
6
作者 Xu Zhang Wei Fan +6 位作者 Ying-Ying Hu Zhi-Ming Li Zhong-Jun Xia Xiao-Ping Lin Ya-Rui Zhang Pei-Yan Liang Yuan-Hua Li 《Chinese Journal of Cancer》 SCIE CAS CSCD 2015年第6期21-28,共8页
Introduction:Fluorine-18 fluorodeoxyglucose(18F-FDG)positron emission tomography/computed tomography(PET/CT)is a powerful tool for monitoring the response of diffuse large B-cell lymphoma(DLBCL)to therapy,but the crit... Introduction:Fluorine-18 fluorodeoxyglucose(18F-FDG)positron emission tomography/computed tomography(PET/CT)is a powerful tool for monitoring the response of diffuse large B-cell lymphoma(DLBCL)to therapy,but the criteria to interpret PET/CT results remain under debate.We investigated the value of post-treatment PET/CT in predicting the prognosis of DLBCL patients when interpreted according to qualitative visual trichotomous assessment(QVTA)criteria compared with the Deauvil e criteria.Methods:In this retrospective study,final PET/CT scans of DLBCL patients treated with rituximab-based regimens between October 2005 and November 2010 were interpreted using the Deauvil e and QVTA criteria.Survival curves were estimated using Kaplan-Meier analysis and compared using the log-rank test.Results:A total of 253 patients were enrol ed.The interpretation according to the Deauvil e criteria revealed that 181patients had negative PET/CT scan results and 72 had positive results.The 3 year overal survival(OS)rate was significantly higher in patients with negative scan results than in those with positive results(91.6%vs.57.5%,P<0.001).The72 patients with positive scan results according to the Deauville criteria were divided into two groups by the interpretation according to the QVTA criteria:29 had indeterminate results,and 43 had positive results.The 3 year OS rate was significantly higher in patients with indeterminate scan results than in those with positive results(91.2%vs.33.5%,P<0.001)but was similar between patients with negative and indeterminate scan results(91.6%vs.91.2%,P=0.921).Conclusions:Compared with the Deauvil e criteria,using the QVTA criteria for interpreting post-treatment PET/CT scans of DLBCL patients is likely to reduce the number of false positive results.The QVTA criteria are feasible for therapeutic outcome evaluation and can be used to guide risk-adapted therapy. 展开更多
关键词 正电子发射断层扫描 计算机断层扫描 B细胞淋巴瘤 脱氧葡萄糖 定性视觉 预后 预测 评估
在线阅读 下载PDF
ASSESSMENT OF MYOCARDIAL VIABILITY WITH CONTRAST-ENHANCED MAGNETIC RESONANCE IMAGING AND COMPARISON WITH SINGLE-PHOTON EMISSION COMPUTED TOMOGRAPHY
7
作者 Yi-ning Wang Zheng-yu Jin +6 位作者 Zhu-hua Zhang Ling-yan Kong Li-bo Chen Lu Zhou Hong-yi Sun Heng Zhang Qi Miao 《Chinese Medical Sciences Journal》 CAS CSCD 2006年第4期239-244,共6页
Objective To compare contrast-enhanced magnetic resonance imaging (ceMRI) with nuclear metabolic imaging for the assessment of myocardial viability in patients with chronic ischemic heart disease. Methods Twenty pa... Objective To compare contrast-enhanced magnetic resonance imaging (ceMRI) with nuclear metabolic imaging for the assessment of myocardial viability in patients with chronic ischemic heart disease. Methods Twenty patients with suspected chronic ischemic heart disease underwent ceMRI and technetium-99m sestamibi single-photon emission computed tomography (SPECT). Patients with positive SPECT results also underwent 18 F-fluorodeoxyglucose (FDG) SPECT. In a 17-segment model, the segmental extent of hyperenhancement (SEH) by ceMRI was compared with segmental FDG and sestamibi uptake by SPECT. Correlation between the extent of hyperenhancement by ceMRI and left ventricular function was analyzed. Seven patients got negative results both in ceMRI and technetium-99m sestamibi SPECT. The rest 13 patients with positive results then underwent ^18F-FDG SPECT. In 221 segments of 13 patients, SEH was (2. 1±8.2)%, (25.0±13.7 )%, and (57. 7±23.6 )% in segments with normal metabolism/perfusion, metabolism/perfusion mismatch, and matched defects, respectively, and there were significant differences between either two of them ( all P 〈 0.05). By receiver operating characteristic curve analysis, the area under the curve was 0. 95 for the differentiation between viable and non-viable segments. At the cutoff value of 34%, SEH optimally differentiated viable from non-viable segments defined by SPECT. Using this threshold, the sensitivity and specificity of ceMRI to detect non-viable myocardium as defined by SPECT were 92% and 93%, respectively. Hyperenhancement size by ceMRI was correlated negatively with the left ventricular ejection fraction ( r = - 0.90, P 〈 0.01 ) and positively with left ventricular volumes ( r = 0. 62 for end-diastolic volume, r = 0.75 for end-systolic volume, both P 〈 0.05 ). Conclusion CeMRI allows assessment of myocardial viability with a high accuracy in patients with chronic ischemic heart disease. 展开更多
关键词 magnetic resonance imaging single-photon emission computed tomography myocardialviability
在线阅读 下载PDF
Impact of random and scattered coincidences from outside of field of view on positron emission tomography/computed tomography imaging with different reconstruction protocols
8
作者 Mahak Osouli Alamdari Pardis Ghafarian +2 位作者 Arman Rahmim Mehrdad Bakhshayesh‑Karam Mohammad Reza Ay 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2023年第12期40-52,共13页
Image quality in positron emission tomography(PET)is affected by random and scattered coincidences and reconstruction protocols.In this study,we investigated the effects of scattered and random coincidences from outsi... Image quality in positron emission tomography(PET)is affected by random and scattered coincidences and reconstruction protocols.In this study,we investigated the effects of scattered and random coincidences from outside the field of view(FOV)on PET image quality for different reconstruction protocols.Imaging was performed on the Discovery 690 PET/CT scanner,using experimental configurations including the NEMA phantom(a body phantom,with six spheres of different sizes)with a signal background ratio of 4:1.The NEMA phantom(phantom I)was scanned separately in a one-bed position.To simulate the effect of random and scatter coincidences from outside the FOV,six cylindrical phantoms with various diameters were added to the NEMA phantom(phantom II).The 18 emission datasets with mean intervals of 15 min were acquired(3 min/scan).The emission data were reconstructed using different techniques.The image quality parameters were evaluated by both phantoms.Variations in the signal-to-noise ratio(SNR)in a 28-mm(10-mm)sphere of phantom II were 37.9%(86.5%)for ordered-subset expectation maximization(OSEM-only),36.8%(81.5%)for point spread function(PSF),32.7%(80.7%)for time of flight(TOF),and 31.5%(77.8%)for OSEM+PSF+TOF,respectively,indicating that OSEM+PSF+TOF reconstruction had the lowest noise levels and lowest coefficient of variation(COV)values.Random and scatter coincidences from outside the FOV induced lower SNR,lower contrast,and higher COV values,indicating image deterioration and significantly impacting smaller sphere sizes.Amongst reconstruction protocols,OSEM+PSF+TOF and OSEM+PSF showed higher contrast values for sphere sizes of 22,28,and 37 mm and higher contrast recovery coefficient values for smaller sphere sizes of 10 and 13 mm. 展开更多
关键词 Positron emission tomography/computed tomography(PET/ct) Random coincidences Scatter coincidences·Time of flight(TOF) Point spread function(PSF) Field of view(FOV) Noise equivalent count rate(NECR) Signal-toNoise ratio(SNR)
在线阅读 下载PDF
Evaluation of response to gemcitabine plus cisplatin-based chemotherapy using positron emission computed tomography for metastatic bladder cancer
9
作者 HakanÖztürk İnançKarapolat 《World Journal of Clinical Cases》 SCIE 2023年第36期8447-8457,共11页
BACKGROUND The purpose of the present study was to examine retrospectively the contribution of 18Fluorodeoxyglucose positron emission tomography computed tomography(18FDG-PET/CT)to the evaluation of response to first-... BACKGROUND The purpose of the present study was to examine retrospectively the contribution of 18Fluorodeoxyglucose positron emission tomography computed tomography(18FDG-PET/CT)to the evaluation of response to first-line gemcitabine plus cispla-tin-based chemotherapy in patients with metastatic bladder cancer.AIM To evaluate the response to Gemcitabine plus Cisplatin-based chemotherapy using 18FDG-PET/CT imaging in patients with metastatic bladder cancer.METHODS Between July 2007 and April 2019,79 patients underwent 18FDG-PET/CT imaging with the diagnosis of Metastatic Bladder Carcinoma(M-BCa).A total of 42 pa-tients(38 male,4 female)were included in the study,and all had been admi-nistered Gemcitabine plus Cisplatin-based chemotherapy.After completion of the therapy,the patients underwent a repeat 18FDG-PET/CT scan and the results were compared with the PET/CT findings before chemotherapy according to European Organisation for the Research and treatment of cancer criteria.Mean age was 66.1 years and standard deviation was 10.7 years(range:41–84 years).RESULTS Of the patients,seven(16.6%)were in complete remission,17(40.5%)were in partial remission,six(14.3%)had a stable disease,and 12(28.6%)had a pro-gressive disease.The overall response rate was 57.1 percent.CONCLUSION 18FDG-PET/CT can be considered as a successful imaging tool in evaluating response to first-line chemotherapy for metastatic bladder cancer.Anatomical and functional data obtained from PET/CT scans may be useful in the planning of secondline and thirdline chemotherapy. 展开更多
关键词 Metastatic bladder cancer Response to chemotheraphy Positron emission tomography computed tomography 18FDG-PET/ct
在线阅读 下载PDF
^(99m)Tc窗宽设置对SPECT图像质量和定量准确性影响的模型研究
10
作者 杨鑫 侯瞻 +5 位作者 杨双臣 宋国庆 秦亚楠 田丛娜 胡玉敬 边艳珠 《中国医疗设备》 2025年第1期15-19,共5页
目的探讨不同采集能窗宽度对单光子发射断层显像仪(Single Photon Emission Computed Tomography,SPECT)图像质量和定量准确性的影响。方法利用美国国家电气制造商协会/国际电工委员会(NEMA/IEC)质控模型,在6个小球和体模腔内分别灌注32... 目的探讨不同采集能窗宽度对单光子发射断层显像仪(Single Photon Emission Computed Tomography,SPECT)图像质量和定量准确性的影响。方法利用美国国家电气制造商协会/国际电工委员会(NEMA/IEC)质控模型,在6个小球和体模腔内分别灌注320和10 kBq/mL ^(99m)TcO_(4)-溶液(球体-本底比为32∶1),主能峰为140 keV,窗宽分别设置为5%、10%、15%、20%;测量不同直径小球的最大摄取值和平均放射性计数值,并于热球旁本底区拷贝相同体积的感兴趣区,自动测量本底平均放射性计数值及标准差;计算本底变异系数(Coefficient of Variation,CV)、球体和背景本底的对比度(Contrast)、小球恢复系数和绝对误差,并对图像进行定量评估。结果随着小球直径增加,各小球的CV值和Contrast逐渐增加。CV值在5%窗宽采集条件下明显高于其他3组,且5%与10%,5%与15%,5%与20%间差异均有统计学意义(P<0.05),其余组两两比较差异均无统计学意义(P>0.05)。Contrast随着采集窗宽的增加而减小,且总体差异有统计学意义(F=15.730,P<0.05)。4种窗宽采集条件下所得恢复系数总体差异有统计学意义(F=10.670,P<0.05),所得的恢复系数平均值20%窗宽时最大,15%窗宽时次之,5%窗宽时最小。4种采集条件下所得绝对误差总体差异有统计学意义(F=11.370,P<0.05),所得的绝对误差平均值15%窗宽时最小,10%窗宽时次之,5%窗宽时最大。结论不同窗宽采集会对SPECT图像质量和定量准确性造成影响。15%窗宽时采集图像CV值较小,Contrast较高,放射性浓度比值较接近真实值,绝对误差最小,推荐临床采集使用。 展开更多
关键词 体层摄影术 单光子发射断层显像仪(spect) 图像质量 定量准确性 窗宽
在线阅读 下载PDF
^(18)F-fluorodeoxyglucose positron emission tomography/computed tomography in intrahepatic cholangiocarcinoma: could it be a new paradigm?
11
作者 Masakatsu Tsurusaki Ryohei Kozuki Atsushi Urase 《Hepatobiliary Surgery and Nutrition》 SCIE 2024年第2期379-381,共3页
Intrahepatic cholangiocarcinoma(iCCA)is the second most common type of liver cancer after hepatocellular carcinoma,accounting for 15%of all primary liver neoplasms.In particular,iCCA is the most lethal tumor of these ... Intrahepatic cholangiocarcinoma(iCCA)is the second most common type of liver cancer after hepatocellular carcinoma,accounting for 15%of all primary liver neoplasms.In particular,iCCA is the most lethal tumor of these types,with the greatest increase in incidence in Western countries over the last decade(1,2).Local resection is the only treatment that can achieve cure,but resection rates remain low and survival is still limited to less than 1 year in the presence of locally unresectable or distant metastases(3).Its incidence and mortality have increased in recent years,and the total number of new cases is expected to increase up to 10-fold over the next two to three decades.In recent years,new treatments for iCCA have been developed and overall survival has improved. 展开更多
关键词 Intrahepatic cholangiocarcinoma(iCCA) STAGING ^(18)F-fluorodeoxyglucose positron emission tomography/computed tomography(^(18)F-FDG PET/ct)
原文传递
应用瑞加诺生负荷D-SPECT评价定量血流分数在经皮冠状动脉介入治疗中的作用 被引量:2
12
作者 李柳 李晓燕 +3 位作者 高志超 郑庆厚 赵甫刚 王硕 《西安交通大学学报(医学版)》 CAS CSCD 北大核心 2024年第3期443-448,共6页
目的应用瑞加诺生负荷动态单光子发射计算机断层扫描(dynamic single-photon emission computed tomography,D-SPECT)评价定量血流分数(quantitative flow ratio,QFR)在经皮冠状动脉介入治疗(percutaneous coronary intervention,PCI)... 目的应用瑞加诺生负荷动态单光子发射计算机断层扫描(dynamic single-photon emission computed tomography,D-SPECT)评价定量血流分数(quantitative flow ratio,QFR)在经皮冠状动脉介入治疗(percutaneous coronary intervention,PCI)中的作用。方法选择2021年6月31日至2023年6月31日在河北医科大学第一医院心内科住院行择期PCI术的200例不稳定型心绞痛患者,年龄(57.56±8.23)岁,按照随机数字表法分为常规组(n=100)和QFR组(n=100),试验采用双盲法进行。常规组根据医师经验行PCI术治疗,QFR组根据QFR测定结果行PCI治疗。所有入选患者术前及PCI术后7 d,应用瑞加诺生负荷D-SPECT,分别采集短轴、垂直长轴、水平长轴的图像,计算心肌17节段分布下心肌灌注总积分、心肌缺血总节段数情况。结果PCI术前两组患者心肌缺血节段数(7.59±3.14 vs.7.48±3.36,P=0.811)、心肌灌注总积分(15.87±7.61 vs.15.63±5.97,P=0.860)差异无统计学意义,QFR组PCI术后7 d的心肌缺血节段数(5.58±3.36 vs.6.51±2.14,P=0.020)和心肌灌注总积分(10.55±4.41 vs.12.96±6.50,P=0.002)显著优于常规组(P<0.05)。结论应用QFR指导PCI可以更好改善患者心肌缺血程度。 展开更多
关键词 瑞加诺生 动态单光子发射计算机断层扫描(D-spect) 经皮冠状动脉介入治疗(PCI) 定量血流分数(QFR)
在线阅读 下载PDF
疑诊原发性甲状旁腺功能亢进症的患者术前^(99m)Tc-MIBI SPECT/CT显像结果的影响因素分析 被引量:1
13
作者 郭月红 黄京伟 +1 位作者 张腾 杨敏福 《首都医科大学学报》 CAS 北大核心 2024年第1期31-35,共5页
目的探讨疑诊原发性甲状旁腺功能亢进症(primary hyperparathyroidism,PHPT)的患者术前^(99m)Tc-甲氧基异丁基异腈(methoxyisobutylisonitrile,MIBI)单光子发射计算机断层扫描/计算机断层扫描(single-photon emission computed tomograp... 目的探讨疑诊原发性甲状旁腺功能亢进症(primary hyperparathyroidism,PHPT)的患者术前^(99m)Tc-甲氧基异丁基异腈(methoxyisobutylisonitrile,MIBI)单光子发射计算机断层扫描/计算机断层扫描(single-photon emission computed tomography/computed tomography,SPECT/CT)(以下简称MIBI SPECT/CT)显像结果的影响因素。方法将2019年1月至2023年8月于首都医科大学附属北京朝阳医院疑诊PHPT并在术前完善甲状旁腺MIBI SPECT/CT显像的257例患者作为研究对象。比较MIBI SPECT/CT显像阳性组和阴性组的实验室检查、病理特征及影像特征。采用多因素Logistic回归分析MIBI SPECT/CT显像结果的影响因素。结果单因素分析显示,与阴性组相比,血清总钙、血清甲状旁腺激素(parathyroid hormone,PTH)、碱性磷酸酶(alkaline phosphatase,ALP)水平在阳性组显著升高(P<0.05);病灶的病理类型、最大径、体积及位置在两组间差异有统计学意义(P<0.05)。多因素Logistic回归分析显示,术前血清PTH水平、病灶病理类型、位置及最大径与MIBI SPECT/CT显像结果阳性显著相关(P<0.05)。结论疑诊PHPT患者术前MIBI SPECT/CT显像结果受多重因素影响,术前血清PTH水平、病灶病理类型、位置及最大径是MIBI SPECT/CT显像结果的独立影响因素。 展开更多
关键词 原发性甲状旁腺功能亢进症(PHPT) ^(99m)Tc-甲氧基异丁基异腈(MIBI) spect/ct
在线阅读 下载PDF
Perioperative Evaluation of Cerebral Blood Flow Using ^123I-labeled N-isopropyl-p-iodoamphetamine Single-Photon Emission Computed Tomography without Blood Sampling in Patients Who Underwent Carotid Artery Stenting
14
作者 Naoki Matsumoto Rei Enatsu +5 位作者 Yasuzumi Matsui Hiroyuki Ikeda Norikazu Yamana Masashi Oda Masaaki Saiki Osamu Narumi 《Chinese Medical Journal》 SCIE CAS CSCD 2016年第13期1616-1618,共3页
The evaluation of regional cerebral vascular reserve (rCVR) with single-photon emission computed tomography (SPECT) is useful for predicting cerebral hyperperfusion following carotid artery stenting (CAS) and ca... The evaluation of regional cerebral vascular reserve (rCVR) with single-photon emission computed tomography (SPECT) is useful for predicting cerebral hyperperfusion following carotid artery stenting (CAS) and carotidendarterectomy (CEA). 展开更多
关键词 Carotid Artery Stenosis Carotid Artery Stenting N-isopropyl-p-iodoamphetamine-Rest and True Acetazolamide Images Estimated Method Using Dynamic Acquisition single-photon emission computed tomography
原文传递
Correlations of single photon emission computed tomography joints scan and bone metabolic markers in active rheumatoid arthritis
15
作者 高海燕 《China Medical Abstracts(Internal Medicine)》 2017年第1期14-15,共2页
Objective To explore the correlation between quantitative value of joint bone scan by single photon emission computed tomography(SPECT)and serum bone metabolic markers in patients with active rheumatoid arthritis(RA).... Objective To explore the correlation between quantitative value of joint bone scan by single photon emission computed tomography(SPECT)and serum bone metabolic markers in patients with active rheumatoid arthritis(RA).Methods Clinical data of 60 newly diagnosed RA patients were retrospectively collected in Department 展开更多
关键词 BONE Correlations of single photon emission computed tomography joints scan and bone metabolic markers in active rheumatoid arthritis spect PINP
原文传递
富于巨细胞型骨肉瘤SPECT/CT影像学表现 被引量:2
16
作者 赵颖 李培岭 刘玉珂 《罕少疾病杂志》 2024年第3期87-89,共3页
目的探讨分析富于巨细胞型骨肉瘤(GCRO)的影像学特征,以提高对该病的诊断水平。方法回顾性分析我院经过病理证实的2例GCRO患者资料并进行文献总结,总结该病的临床、病理及影像特征,并随访最终结局。结果男性患者1例,38岁,股骨旁GCRO,女... 目的探讨分析富于巨细胞型骨肉瘤(GCRO)的影像学特征,以提高对该病的诊断水平。方法回顾性分析我院经过病理证实的2例GCRO患者资料并进行文献总结,总结该病的临床、病理及影像特征,并随访最终结局。结果男性患者1例,38岁,股骨旁GCRO,女性患者1例,76岁,股骨近端髓腔型GCRO。(1)骨旁GCRO的影像表现:病变位于骨旁,DR表现为骨旁软组织内钙化影,形态不规则;CT表现为骨旁密度不均匀的肿块,内见位于肿块基底部的不规则团状钙化或骨化影,肿块约包绕股骨干的90%;全身骨显像及SPECT/CT融合图像表现为肿块内放射性核素异常浓聚。(2)髓腔型GCRO的影像表现:病变位于股骨近端,CT表现为膨胀性偏心性溶骨性骨质破坏,边缘不连,未见明显骨膜反应;全身骨显像及SPECT/CT图像表现为病变区边缘及中心区的不规则状放射性核素异常浓聚;结论GCRO罕见,影像学易误诊,常规影像学检查具有一定的特征性影像学表现,SPECT/CT结合常规影像学检查有助于诊断,确诊需结合多种影像学资料和组织病理学检查。 展开更多
关键词 巨细胞 骨肉瘤 体层摄影术 X线计算机 spect/ct
在线阅读 下载PDF
Study of hydraulic fracture growth behavior in heterogeneous tight sandstone formations using CT scanning and acoustic emission monitoring 被引量:10
17
作者 Nai-Zhen Liu Yu-Shi Zou +2 位作者 Xin-Fang Ma Ning Li Shan Wu 《Petroleum Science》 SCIE CAS CSCD 2019年第2期396-408,共13页
Tortuous hydraulic fractures(HFs) are likely to be created in heterogeneous formations such as conglomerates, which may cause sand plugging, ultimately resulting in poor stimulation efficiency. This study aims to expl... Tortuous hydraulic fractures(HFs) are likely to be created in heterogeneous formations such as conglomerates, which may cause sand plugging, ultimately resulting in poor stimulation efficiency. This study aims to explore HF growth behavior in conglomerate through laboratory fracturing experiments under true tri-axial stresses combined with computed tomography scanning and acoustic emission(AE) monitoring. The effects of gravel size, horizontal differential stress, and AE focal mechanisms were examined. Especially, the injection pressure and the AE response features during HF initiation and propagation in conglomerate were analyzed. Simple HFs with narrow microfractures are created in conglomerate when the gravels are considerably smaller than the specimen, whereas complex fractures are created when the gravels are similar in size to the specimen, even under high horizontal differential stresses. Breakdown pressure and AE rates are high when a HF is initiated from the high-strength gravel. A large pressure decline after the breakdown may indicate the creation of a planar and wide HF. Analyzing the focal mechanism indicates that the shear mechanism generally dominates with an increase in the HF complexity. Tensile events are likely to occur during HF initiation and are located around the wellbore. Shear events occur mainly around the nonplanar and complex matrix/gravel interfaces. 展开更多
关键词 CONGLOMERATE GRAVEL HYDRAULIC FRActURING Propagation mechanism computed tomography (ct) Acoustic emission (AE)
在线阅读 下载PDF
Acoustic emission characterization of microcracking in laboratory-scale hydraulic fracturing tests 被引量:9
18
作者 Jesse Hampton Marte Gutierrez +2 位作者 Luis Matzar Dandan Hu Luke Frash 《Journal of Rock Mechanics and Geotechnical Engineering》 CSCD 2018年第5期805-817,共13页
Understanding microcracking near coalesced fracture generation is critically important for hydrocarbon and geothermal reservoir characterization as well as damage evaluation in civil engineering structures. Dense and ... Understanding microcracking near coalesced fracture generation is critically important for hydrocarbon and geothermal reservoir characterization as well as damage evaluation in civil engineering structures. Dense and sometimes random microcracking near coalesced fracture formation alters the mechanical properties of the nearby virgin material. Individual microcrack characterization is also significant in quantifying the material changes near the fracture faces (i.e. damage). Acoustic emission (AE) monitoring and analysis provide unique information regarding the microcracking process temporally, and infor- mation concerning the source characterization of individual microcracks can be extracted. In this context, laboratory hydraulic fracture tests were carried out while monitoring the AEs from several piezoelectric transducers. In-depth post-processing of the AE event data was performed for the purpose of under- standing the individual source mechanisms. Several source characterization techniques including moment tensor inversion, event parametric analysis, and volumetric deformation analysis were adopted. Post-test fracture characterization through coring, slicing and micro-computed tomographic imaging was performed to determine the coalesced fracture location and structure. Distinct differences in fracture characteristics were found spatially in relation to the openhole injection interval. Individual microcrack AE analysis showed substantial energy reduction emanating spatially from the injection interval. It was quantitatively observed that the recorded AE signals provided sufficient information to generalize the damage radiating spatially away from the injection wellbore. 展开更多
关键词 Acoustic emission (AE) Microcracking Hydraulic fracturing Laboratory-scale testing Moment tensor analysis Fracture coalescence computed tomography ct imaging
在线阅读 下载PDF
^(18)F-FCH PET/CT在原发与继发性甲状旁腺功能亢进中的对比研究
19
作者 费子航 王政杰 +1 位作者 勾亚婷 庞华 《放射学实践》 北大核心 2025年第1期107-113,共7页
目的:对比^(18)F-FCH PET/CT在原发性甲状旁腺功能亢进(PHPT)与继发性甲状旁腺功能亢进(SHPT)中的应用价值,并比较18F-FCH PET/CT影像参数在两者间的差异。方法:回顾性搜集行^(18)F-FCH PET/CT显像的甲状旁腺亢进症患者50例(PHPT 28例,S... 目的:对比^(18)F-FCH PET/CT在原发性甲状旁腺功能亢进(PHPT)与继发性甲状旁腺功能亢进(SHPT)中的应用价值,并比较18F-FCH PET/CT影像参数在两者间的差异。方法:回顾性搜集行^(18)F-FCH PET/CT显像的甲状旁腺亢进症患者50例(PHPT 28例,SHPT 22例)。通过t检验或非参数检验、Spearman相关性分析比较其临床生化指标、^(18)F-FCH PET/CT显像参数及其诊断效能等方面的差异,比较^(18)F-FCH PET/CT相关参数在PHPT与SHPT间的差异,同时探讨临床生化指标与PET参数间的相关性。结果:血钙、血磷、甲状旁腺激素、降钙素、MTV总和、TLFM总和在PHPT与SHPT两组间差异有统计学意义(P均<0.05),而SUV_(max)差异无统计学意义(P=0.072)。^(18)F-FCH PET/CT检测PHPT更具优势,其诊断敏感度(分别为96.8%和74.6%)和阳性预测值(分别为96.8%和89.8%)均高于SHPT。血磷水平、SUV_(mean)总和鉴别诊断PHPT与SPHT的效能优于其他指标,其截断值分别为1.175(AUC=0.918)、3.4(AUC=0.8417)。PTH与SUV_(max)、MTV总和、TLFM总和等PET参数存在正相关性,其余临床指标与PET参数无明显相关性。结论:部分^(18)F-FCH PET/CT影像参数及临床生化指标在PHPT与SHPT间差异有统计学意义,且PET/CT影像参数对PHPT的检测效能明显高于SHPT。在甲状旁腺功能亢进患者中,甲状旁腺激素与SUV_(max)、MTV总和、TLFM总和具有正相关性。 展开更多
关键词 甲状旁腺功能亢进症 ^(18)F-FCH PET/ct 正电子发射计算机体层成像 体层摄影术 X线计算机
在线阅读 下载PDF
The influence of ^(18)F-fluorodeoxyglucose positron emission tomography/computed tomography on the N-and M-staging and subsequent clinical management of intrahepatic cholangiocarcinoma 被引量:6
20
作者 Youpei Lin Huanhuan Chong +14 位作者 Guohe Song Chenhao Zhang Liangqing Dong Ling Aye Fei Liang Shuaixi Yang Mengsu Zeng Guangyu Ding Shu Zhang Jieyi Shi Aiwu Ke Xiaoying Wang Jian Zhou Jia Fan Qiang Gao 《Hepatobiliary Surgery and Nutrition》 SCIE 2022年第5期684-695,I0002-I0007,共18页
Background:Intrahepatic cholangiocarcinoma(ICC)is a highly metastatic cancer.^(18)F-fluorodeoxyglucose positron emission tomography/computed tomography(^(18)F-FDG PET/CT)enables sensitive tumor and metastasis detectio... Background:Intrahepatic cholangiocarcinoma(ICC)is a highly metastatic cancer.^(18)F-fluorodeoxyglucose positron emission tomography/computed tomography(^(18)F-FDG PET/CT)enables sensitive tumor and metastasis detection.Our aim is to evaluate the influence of pre-treatment PET/CT on the N-and M-staging and subsequent clinical management in ICC patients.Methods:Between August 2010 and August 2018,660 consecutive ICC patients,without prior anti-tumor treatments nor other malignancies,were enrolled.The diagnostic performance of PET/CT on the N-and M-staging was compared with conventional imaging,and the preoperative staging accuracy and treatment re-allocation by PET/CT were retrospectively calculated.Survival difference was compared between patients receiving PET/CT or not after propensity score matching.Results:Patients were divided into group A(n=291)and group B(n=369)according to whether PET/CT was performed.Among 291 patients with both PET/CT and conventional imaging for staging in group A,PET/CT showed significantly higher sensitivity(83.0%vs.70.5%,P=0.001),specificity(88.3%vs.74.9%,P<0.001)and accuracy(86.3%vs.73.2%,P<0.001)than conventional imaging in diagnosing regional lymph node metastasis,as well as higher sensitivity(87.8%vs.67.6%,P<0.001)and accuracy(93.5%vs.89.3%,P=0.023)in diagnosing distant metastasis.Overall,PET/CT improved the accuracy of preoperative staging from 60.1%to 71.8%(P<0.001),and modified clinical treatment strategy in 5.8%(17/291)of ICC patients,with unique roles in different tumor-node-metastasis(TNM)stages.High tumor-to-non-tumor ratio(TNR)predicted poor overall survival[hazard ratio(HR)=2.17;95%confidence interval(CI):1.49-3.15;P<0.001].Furthermore,patients performing PET/CT had longer overall survival compared with those without PET/CT(HR=0.74;95%CI:0.58-0.93;P=0.011)after propensity score matching.Conclusions:PET/CT was valuable for diagnosing regional lymph node metastasis and distant metastasis in ICC patients,and facilitated accurate tumor staging and optimal treatment allocation. 展开更多
关键词 Intrahepatic cholangiocarcinoma(ICC) STAGING positron emission tomography/computed tomography(PET/ct) clinical management
原文传递
上一页 1 2 19 下一页 到第
使用帮助 返回顶部