Determination on Heavy Metals Content of Achyranthes bidentata Blume. through Inductively Coupled Plasma Mass Spectrometry (ICP-MS) 被引量:4
1
作者 李宇伟 王新民 +3 位作者 连瑞丽 魏志华 介晓磊 陈士林 《Agricultural Science & Technology》 CAS 2008年第5期145-149,共5页
[Objective] The inductively coupled plasma mass spectrometry(ICP-MS)was constructed to determine the contents of lead,cadmium,mercury and arsenic in Archyranthes bidentata Blume.[Method]Under the optimum operation con... [Objective] The inductively coupled plasma mass spectrometry(ICP-MS)was constructed to determine the contents of lead,cadmium,mercury and arsenic in Archyranthes bidentata Blume.[Method]Under the optimum operation condition of ICP-MS,the samples were digested by microwave.The element 114In was taken as an internal standard element to compensate body effect and ICP-MS method was used to determine the contents of lead,cadmium,mercury and arsenic.[Result]For the determined elements,the correlation coefficient(r)of standard curve was over 0.9995 and recovery rate was from 96.7% to 106.4% while RSD was less than 11.2%.The result of determination showed that the heavy metal content in Archyranthes bidentata Blume.beyond standard was serious.[Conclusion]The constructed ICP-MS method with simple operation,rapid response,accuracy and high sensitivity in this experiment could be used for quality control of Chinese medicinal materials by detecting heavy metal contents in different Chinese medicinal materials from original places. 展开更多
关键词 MICROWAVE DIGESTION inductively coupled plasma mass spectrometry(icp-ms) Achyranthes bidentata Blume. HEAVY metal
在线阅读 下载PDF
Inductively coupled plasma mass spectrometry (ICP-MS) and its application in life sciences
2
作者 徐谷峰 王红梅 《Plasma Science and Technology》 SCIE EI CAS CSCD 2001年第4期921-925,共5页
Inductively-coupled plasma mass spectrometry (ICP-MS) has made much progress since its birth in the late 1990s. This paper will give a rather systematic overview on the use of this technique in new devices and technol... Inductively-coupled plasma mass spectrometry (ICP-MS) has made much progress since its birth in the late 1990s. This paper will give a rather systematic overview on the use of this technique in new devices and technologies related to plasma source, sample-introducing device and detecting spectrometer etc. In this overview, an emphasis will be put on the evaluation of the ICP- MS technique in combination with a series of physical, chemical and biological techniques, such as laser ablation (LA), capillary electrophoresis (CE) and high performance liquid chromatograph (HPLC), along with their representative high accuracy and high sensitivity. Finally, comprehensive and fruitful applications of the ICP-MS and its combinative techniques in the detection of trace metallic elements and isotopes in complex biological and environmental samples will be revealed. 展开更多
关键词 icp-ms inductively coupled plasma mass spectrometry and its application in life sciences MS
在线阅读 下载PDF
Determination of impurity elements in MnZn ferrites by inductively coupled plasma mass spectrometry 被引量:3
3
作者 张萍 符靓 +1 位作者 马俊才 唐有根 《Journal of Central South University》 SCIE EI CAS CSCD 2015年第1期37-42,共6页
An inductively coupled plasma mass spectrometry(ICP-MS) method was developed for the determination of Na, Mg, Al,K, Ca, Ti, Cr, Co, Ni, Cu, Ga, As, Mo, Ag, Cd and Pb in MnZn ferrites. The sample was digested by HNO3+H... An inductively coupled plasma mass spectrometry(ICP-MS) method was developed for the determination of Na, Mg, Al,K, Ca, Ti, Cr, Co, Ni, Cu, Ga, As, Mo, Ag, Cd and Pb in MnZn ferrites. The sample was digested by HNO3+HCl with microwave digestion followed by dilution with ultrapure water, then the above 16 impurity elements in the solution were analyzed directly by ICP-MS. The impurity elements were introduced by the helium gas or hydrogen gas into the octopole reaction system(ORS) to eliminate the polyatomic interferences caused by the high salty matrixes. The matrix effect was minimized through matrix matching,and Be, Y and Rh were used as internal standard elements. The working parameters of the instrument were optimized. The results show that the method has good precision and high accuracy. The detection limits for the investigated elements are in the range of0.9-37.5 ng/L, the relative standard deviation of each element is within 1.1%-4.8%, and the recovery of each element is 90%-108%. 展开更多
关键词 inductively coupled plasma mass spectrometry(icp-ms MnZn ferrites octopole reaction system(ORS) impurity elements
在线阅读 下载PDF
Uncertainty Evaluation of Simultaneous Determination of Lead, Cadmium and Arsenic in Cosmetics by Inductively Coupled Plasma Mass Spectrometry 被引量:1
4
作者 Cui Xiaojiao Wang Hui +3 位作者 Zhou Peng Zhou Tanchun Cao Xiongjie Hu Yuge 《China Detergent & Cosmetics》 2020年第1期68-74,共7页
This study aimed to evaluate the uncertainty of simultaneous determination of lead(Pb),cadmium(Cd)and arsenic(As)in cosmetics by microwave digestion-inductively coupled plasma mass spectrometry(ICP-MS)with ^72Ge,^115I... This study aimed to evaluate the uncertainty of simultaneous determination of lead(Pb),cadmium(Cd)and arsenic(As)in cosmetics by microwave digestion-inductively coupled plasma mass spectrometry(ICP-MS)with ^72Ge,^115In and ^209Bi as internal standards.According to the method of Safety and Technical Standards for Cosmetics(2015),a mathematical model was established to evaluate the sources and components of uncertainty for the determination of lead,cadmium and arsenic in cosmetics.The results showed that the uncertainties in the determination of lead,cadmium,and arsenic elements in cosmetics were(10.1±0.6)mg/kg,k=2,(4.84±0.28)mg/kg,k=2,(2.04±0.18)mg/kg,k=2,respectively.The main factors that affect the uncertainty of determination results were standard substance,calibration curve,recovery and measurement repeatability. 展开更多
关键词 COSMETICS uncertainty inductively coupled plasma mass spectrometry(icp-ms) heavy metals
在线阅读 下载PDF
三重串联四极杆-电感耦合等离子体质谱(ICP-MS)法测定金属铜/镍/钴中的磷
5
作者 孙梦荷 刘春峰 +3 位作者 方迪 苏春风 董梦君 陈殿耿 《中国无机分析化学》 北大核心 2025年第3期406-413,共8页
针对传统萃取分光光度法在测定金属铜、镍、钴中磷含量时存在的预处理流程繁琐、耗时较长以及使用多种有害有机试剂对环境与健康构成潜在威胁的问题,通过引入质谱的动态反应模式(DRC),利用^(31)P^(+)与池中O_(2)的反应,通过在m/z=47处检... 针对传统萃取分光光度法在测定金属铜、镍、钴中磷含量时存在的预处理流程繁琐、耗时较长以及使用多种有害有机试剂对环境与健康构成潜在威胁的问题,通过引入质谱的动态反应模式(DRC),利用^(31)P^(+)与池中O_(2)的反应,通过在m/z=47处检测^(31)P^(+)的氧化物离子^(31)P^(16)O^(+),从而实现磷的定量分析,有效解决了多原子离子干扰这一关键难题。在DRC模式下,这一过程不仅提高了磷离子的检测特异性,还显著增强了信号强度,从而确保了分析结果的准确性。通过优化DRC系统工作条件,在O_(2)流速为0.9 mL/min的条件下获得^(31)P^(16)O^(+)的最佳信噪比。为了进一步克服金属铜、镍、钴基体可能产生的基体效应,采用标准加入法的测定方式,实验结果与国家标准方法分光光度法的比对结果高度一致。方法的线性范围为0.0001%~0.0050%,线性相关系数均在0.999 5以上。同时,金属铜、镍、钴中磷的检出限均低于0.3 ng/mL。在实际样品测定中,方法的相对标准偏差控制在4.1%~13.8%,回收率则在94.9%~118%,均符合分析化学的常规要求,方法具有良好的精密度和准确度。三重串联四极杆-电感耦合等离子体质谱(ICP-MS)法在测定金属铜、镍、钴样品中的磷含量方面展现出了卓越的性能,为金属材料中痕量元素的测定提供了一种高效、环保的新途径。 展开更多
关键词 三重串联四极杆电感耦合等离子体质谱仪(icp-ms/ms) 金属铜/镍/钴 DRC
在线阅读 下载PDF
氧气反应模式-四极杆ICP-MS定量高温合金中痕量元素及质谱干扰消除机理研究 被引量:2
6
作者 冯媛媛 周涛 +2 位作者 唐一川 张见营 李彭辉 《质谱学报》 EI CAS CSCD 北大核心 2024年第4期531-539,I0004,共10页
本研究建立了氧气反应模式-四极杆电感耦合等离子体质谱(Q-ICP-MS)法准确定量高温合金中痕量杂质元素,对不同碰撞/反应模式消除质谱干扰的效果进行研究。结果表明,氧气动态反应池(DRC-O_(2))模式下,目标元素Cd的多原子离子质谱干扰能够... 本研究建立了氧气反应模式-四极杆电感耦合等离子体质谱(Q-ICP-MS)法准确定量高温合金中痕量杂质元素,对不同碰撞/反应模式消除质谱干扰的效果进行研究。结果表明,氧气动态反应池(DRC-O_(2))模式下,目标元素Cd的多原子离子质谱干扰能够被有效去除;在优化气流为2 mL/min时,信噪比达到最高,检出限较标准模式(STD)降低了近3个数量级。此外,还研究了质谱干扰的消除机理,发现对于元素X(X=Rb、Nb、Mo、Cs、Ta、W或U),当X-O键能大于O-O键能时,质谱干扰组分XO转化成非干扰组分XOO为自发反应,因此,O_(2)充足时更容易生成XOO,从而消除XO干扰。在此基础上,采用高浓度基体模拟溶液(Mo、Nb、Ta、W)分别对痕量Cd、Ag、Au、Hg元素测量的方法学参数进行评估,方法检出限0.08~0.31μg/g、测量重复性相对标准偏差(RSD)2.3%~3.1%(n=6),加标回收率98%~103%,并进一步使用高温合金标准物质验证了方法的可靠性。最后,对3类典型牌号高温合金样品中的痕量杂质进行测量,证明该方法的分析速度快、检出限低、准确可靠,能够满足高温合金中主量Mo、Nb、Ta、W元素存在时被干扰杂质的测量要求。 展开更多
关键词 四极杆电感耦合等离子体质谱(Q-icp-ms) 高温合金 质谱干扰 痕量元素 机理研究
在线阅读 下载PDF
ICP-MS法分析过氧化氢、硝酸、硫酸中的金属杂质 被引量:3
7
作者 黄曜 黄郁芳 《质谱学报》 EI CAS CSCD 2005年第z1期15-16,共2页
Inductively coupled plasma mass spectrometry (ICP-MS) was used to detect trace metal impurities in reagents such as H2O2, HNO3and H2SO4. The limit of detection to metal elements can be down to 2-20 ng/L in H2O2 and HN... Inductively coupled plasma mass spectrometry (ICP-MS) was used to detect trace metal impurities in reagents such as H2O2, HNO3and H2SO4. The limit of detection to metal elements can be down to 2-20 ng/L in H2O2 and HNO3 and 0.1-1.0 ng/L in H2SO4. 展开更多
关键词 inductively coupled plasma mass spectrometry (icp-ms) metal IMPURITIES REAGENTS
在线阅读 下载PDF
ICP-MS测定硼矿区饮用水和尿样中的硼及多种元素
8
作者 杨红霞 李冰 《质谱学报》 EI CAS CSCD 2005年第z1期17-18,共2页
The application of inductively coupled plasma mass spectrometry (ICP-MS) for determination of boron in water and urine samples was described. The detect limit (3σ) was 0.057 μg/L. The precision of the method was les... The application of inductively coupled plasma mass spectrometry (ICP-MS) for determination of boron in water and urine samples was described. The detect limit (3σ) was 0.057 μg/L. The precision of the method was less than 2%. Multi-elements including Cr, Cu, Cd, Ba, Sr, Mn, Co, Tl, Li, Pb, Ca, Fe, K, Na, Mg, P, Si and Zn could be measured simultaneously. The method was successfully used in practice. 展开更多
关键词 inductively coupled plasma mass spectrometry (icp-ms) BORON water URINE
在线阅读 下载PDF
Determination of Pb, Cr, Ni and Mn in Tap Water of Riyadh Metropolitan City Using ICP-MS after Preconcentration with Multiwalled Carbon Nanotubes 被引量:1
9
作者 A. Ahmad K. Omer H.M. Al-Swaidan 《Journal of Environmental Science and Engineering》 2010年第8期26-35,共10页
The determination of toxic metals in water using multiwalled carbon nanotubes (MWNTs) as a solid-phase extraction adsorbent prior to their determination by inductively coupled plasma mass spectrometry (ICP-MS) has... The determination of toxic metals in water using multiwalled carbon nanotubes (MWNTs) as a solid-phase extraction adsorbent prior to their determination by inductively coupled plasma mass spectrometry (ICP-MS) has been investigated. Standard addition method was applied for the calibration using aqueous solutions. Multiwalled carbon nanotubes (MWNTs) absorb these metals at pH 8.0, HNO3 of 1.0 mol-Ll is used for complete elusion of these metals from MWNTs. Previously investigated parameters have been applied for the determination of Pb, Cr, Ni and Mn in tap water samples. Fifteen tap water samples from different locations of Riyadh metropolitan area have been determined by ICP-MS after preconcentration with MWNTs. 展开更多
关键词 Multiwalled carbon nanotubes solid phase extraction PTFE micro-column heavy metals inductively coupled plasma mass spectrometry (icp-ms).
在线阅读 下载PDF
Determination of Fe, Cu, and Zn in Water Samples by Microcolumn Packed with Multiwalled Carbon Nanotubes as a Solid Phase Extraction Adsorbent Using ICP-MS
10
作者 A. Ahmad H.M. Al-Swaidan 《Journal of Environmental Science and Engineering》 2011年第4期410-419,共10页
The heavy metals determination in tap water samples using microcolumn packed with multiwalled carbon nanotubes (MWNTs) as a solid-phase extraction adsorbent before to their determination by inductively coupled plasm... The heavy metals determination in tap water samples using microcolumn packed with multiwalled carbon nanotubes (MWNTs) as a solid-phase extraction adsorbent before to their determination by inductively coupled plasma mass spectrometry (ICP-MS) has been studied. Standard addition method was applied for the calibration using aqueous solutions. The metals ions absorption were achieved by multiwalled carbon nanotubes (MWNTs) at pH 8.0, and then these retained metals on MWNTs column were eluted by 1.0 mol.L^-1 HNO3. The analytical parameters for the determination ofFe, Cu, and Zn in tap water samples which have been investigated previously were applied. Fifteen tap water samples were collected from different locations of Riyadh metropolitan area and then determined the concentration ofFe, Cu, and Zn by ICP-MS after preconcentration with MWNTs. The concentration range for Fe, Cu, and Zn measured (μg/L) in water samples are 23.37-137.91, 2.12-121.36, and 14.43-202.47 respectively. The level of Fe exceeded the limits set by WHO and SASO for drinking water. 展开更多
关键词 Multiwalled carbon nanotubes (MWNTs) solid phase extraction (SPE) heavy metals nitric acid (HNO3) PTFE micro-column inductively coupled plasma mass spectrometry (icp-ms).
在线阅读 下载PDF
微波消解ICP-MS/MS测定沥青中25种无机元素
11
作者 王行智 张文 +2 位作者 陈婷 白雪 田振 《石油沥青》 2023年第2期25-29,共5页
通过优化微波消解程序和仪器条件,采用电感耦合等离子体串联质谱对沥青中25种无机元素含量分析,同时作方法学考察.结果表明,在一定线性范围内,测定的25种无机元素线性关系良好,相关系数在0.9990~1.0000之间;检出限为0.025~1.550μg/L,... 通过优化微波消解程序和仪器条件,采用电感耦合等离子体串联质谱对沥青中25种无机元素含量分析,同时作方法学考察.结果表明,在一定线性范围内,测定的25种无机元素线性关系良好,相关系数在0.9990~1.0000之间;检出限为0.025~1.550μg/L,定量限为0.083~5.166μg/L,加标回收率在85.26%~111.5%之间,各元素精密度(n=6)在0.94%~6.10%之间.此方法操作便捷、灵敏度好,可同时对沥青中25种元素快速分析测定,适于沥青中无机元素的日常分析检验. 展开更多
关键词 沥青 无机元素 微波消解 串联四极杆电感耦合等离子体质谱法
在线阅读 下载PDF
电感耦合等离子体发射光谱与质谱分析技术和应用研究进展
12
作者 冯先进 郑国经 《中国无机分析化学》 北大核心 2025年第3期353-362,共10页
电感耦合等离子体发射光谱(ICP-OES)和电感耦合等离子体质谱(ICP-MS)分析技术都是以ICP为激发源或离子源的无机元素分析技术,在仪器操作、标准物质的配制及进样方式上均有相似之处,成为无机元素测定的得力工具,其溶液进样方式具有朔源... 电感耦合等离子体发射光谱(ICP-OES)和电感耦合等离子体质谱(ICP-MS)分析技术都是以ICP为激发源或离子源的无机元素分析技术,在仪器操作、标准物质的配制及进样方式上均有相似之处,成为无机元素测定的得力工具,其溶液进样方式具有朔源性而被各个领域的标准分析方法所采纳,ICP-OES/MS分析方法在标准化方面得到了较快发展。对近年来ICP-OES仪器的现状、分析功能的发展及其应用上的进展进行综述,对ICP-MS分析技术的发展、四极杆电感耦合等离子体质谱分析(ICP-QMS)仪器的进展以及在纳米颗粒分析、生物化学、形态分析、地质年代学等领域中应用的进展进行评述。ICP-OES/MS作为无机元素分析强有力的实用工具,必将在材料研制、工业检测、食品安全、环境监测、医疗卫生防控、石油化工、新能源等行业中,成为无机元素分析测定的主要手段。 展开更多
关键词 电感耦合等离子体发射光谱 电感耦合等离子体质谱 微型化 智能化 串联四极杆质谱
在线阅读 下载PDF
串联四极杆电感耦合等离子体质谱测定石脑油中痕量硫
13
作者 朱乾华 刘宏伟 黄建华 《石油学报(石油加工)》 EI CAS CSCD 北大核心 2024年第6期1707-1713,共7页
基于串联四极杆电感耦合等离子质谱(ICP-MS)建立了测定石脑油中痕量硫(S)的分析方法。石脑油经有机溶剂简单稀释后直接采用串联四极杆ICP-MS进行测定。在MS/MS模式下,选择N_(2)O作为反应气,基于S^(+)与N_(2)O分别发生O原子转移反应和N... 基于串联四极杆电感耦合等离子质谱(ICP-MS)建立了测定石脑油中痕量硫(S)的分析方法。石脑油经有机溶剂简单稀释后直接采用串联四极杆ICP-MS进行测定。在MS/MS模式下,选择N_(2)O作为反应气,基于S^(+)与N_(2)O分别发生O原子转移反应和N原子转移反应消除质谱干扰,优化了利用质量转移反应消除干扰的分析条件。通过与传统的O_(2)反应模式进行对比分析显示了该方法具有良好的分析性能,采用标准参考物质验证了该方法的准确性和可靠性。结果表明:在N_(2)O流速为0.25 mL/min条件下,S质量分数的检出限(LOD)分别为19.6 ng/kg(^(32)S)和23.5 ng/kg(^(34)S);相对标准偏差(RSD)小于4.5%;回收率为96.3%~104.0%。所建立的分析方法,样品处理简单,分析灵敏度高,准确性和精密度好,适用于石脑油中痕量S的快速测定。 展开更多
关键词 石脑油 串联四极杆电感耦合等离子体质谱 氧化氮 氮原子转移
在线阅读 下载PDF
ICP-QQQ-MS法分析婴幼儿谷物辅助食品中镉含量的干扰及其校正 被引量:1
14
作者 蔡玮 赵博 +4 位作者 赵少雷 陈欢欢 李潇 逯海 韦超 《食品科学》 EI CAS CSCD 北大核心 2024年第14期234-239,共6页
建立三重串联四极杆电感耦合等离子体质谱(inductively coupled plasma triple quadrupole mass spectrometry,ICP-QQQ-MS)法测定婴幼儿谷物辅助食品中镉(Cd)含量的方法。研究单四极杆氦气碰撞模式(SQ-He)、串联四极杆氦气碰撞模式(QQQ-... 建立三重串联四极杆电感耦合等离子体质谱(inductively coupled plasma triple quadrupole mass spectrometry,ICP-QQQ-MS)法测定婴幼儿谷物辅助食品中镉(Cd)含量的方法。研究单四极杆氦气碰撞模式(SQ-He)、串联四极杆氦气碰撞模式(QQQ-He)、串联四极杆氧气反应模式(QQQ-O_(2))3种碰撞/反应模式下质谱测量中存在的各类干扰,并进行逐一分析、消除。结果显示,抗基体、抗氧化物和多原子离子干扰能力均为QQQ-O_(2)>QQQ-He>SQ-He,采用QQQ-O_(2)模式联合标准加入法可获得更为准确的干扰消除效果。通过引入干扰校正方程,有效解决由于同量异位素锡(Sn)干扰导致的Cd同位素丰度比与天然丰度比不一致问题。QQQ-O_(2)模式下同位素稀释质谱法与标准加入法测量Cd的结果等效一致,证明婴幼儿谷物辅助食品中Cd测量时受到的基体效应和质谱干扰被有效消除。所建方法为使用ICP-QQQ-MS准确测定复杂基体样品中Cd提供重要参考。 展开更多
关键词 三重串联四极杆电感耦合等离子体质谱 质谱干扰 同位素稀释质谱 基体效应
在线阅读 下载PDF
ICP-MS/MS测定镍基高温合金中痕量金、汞和硒的质谱干扰消除 被引量:1
15
作者 王昭颖 陈雄飞 +4 位作者 徐彦 墨淑敏 张芳 童坚 刘英 《分析试验室》 EI CAS CSCD 北大核心 2024年第8期1183-1189,共7页
采用单四极杆质谱(ICP-MS)无法消除第二代镍基单晶高温合金CMSX-4中合金元素Ta,W,Ni及载气Ar所形成的多原子离子对痕量杂质元素Au,Hg和Se产生的质谱干扰。本研究基于三重四极杆-电感耦合等离子体质谱(ICP-MS/MS)技术,通过考察不同碰撞/... 采用单四极杆质谱(ICP-MS)无法消除第二代镍基单晶高温合金CMSX-4中合金元素Ta,W,Ni及载气Ar所形成的多原子离子对痕量杂质元素Au,Hg和Se产生的质谱干扰。本研究基于三重四极杆-电感耦合等离子体质谱(ICP-MS/MS)技术,通过考察不同碰撞/反应模式(No Gas模式、He模式、O_(2)原位质量模式、O_(2)质量转移模式)下的质谱干扰消除效果,建立了CMSX-4中痕量杂质元素Au,Hg和Se的测定方法。结果表明,采用O_(2)原位质量模式能够有效消除Ta O^(+)对Au^(+)和WO^(+)对Hg^(+)的质谱干扰;采用O_(2)质量转移模式能够消除Ni O^(+)和ArAr^(+)对Se^(+)的质谱干扰。综合考虑3种待测元素的信号强度及背景等效浓度,确定O_(2)流速为0.60 m L/min。通过考察内标元素对基体效应的校正效果,选择^(133)Cs为测定Au和Hg的内标元素、^(103)Rh为测定Se的内标元素。在优化条件下,建立了Au,Hg和Se的工作曲线,线性相关系数均为0.9991,方法检出限为0.11~0.29 ng/m L。分别对3个添加水平的镍基高温合金样品独立测定9次,相对标准偏差(RSD)为2.0%~9.5%。Au和Hg的加标回收率为96.1%~107.2%。采用本方法对镍基高温合金有证标准物质中的Se的质量浓度进行测定,经t检验表明测定结果与标准值无显著性差异。 展开更多
关键词 三重四极杆-电感耦合等离子体串联质谱(icp-ms/ms) CMSX-4镍基单晶高温合金 痕量杂质元素 质谱干扰消除
原文传递
微波消解-三重四级杆电感耦合等离子体质谱法同时测定地球化学土壤中锗、砷、硒、镉、锡、碲 被引量:1
16
作者 隋东 杨林 +2 位作者 邹国庆 周武权 李海娟 《化学分析计量》 CAS 2024年第5期60-65,共6页
建立微波消解-三重四极杆电感耦合等离子体质谱法测定地球化学土壤中的锗、砷、硒、镉、锡、碲。在4mL硝酸-1 mL氢氟酸体系下,采用微波消解样品,利用三重四极杆电感耦合等离子体质谱仪的氧气反应模式和氦气碰撞模式去除干扰,氧气、氦气... 建立微波消解-三重四极杆电感耦合等离子体质谱法测定地球化学土壤中的锗、砷、硒、镉、锡、碲。在4mL硝酸-1 mL氢氟酸体系下,采用微波消解样品,利用三重四极杆电感耦合等离子体质谱仪的氧气反应模式和氦气碰撞模式去除干扰,氧气、氦气流量分别为0.25 mL/min和4 mL/min。通过向样品溶液中加入甲醇,使硒、碲检测灵敏度分别提高了约90%、40%;选用高灵敏截取锥嵌片,使硒、碲检测灵敏度均提高了约30%。锗、砷、硒、镉、锡、碲6种元素的质量浓度在一定范围内与荷质比强度线性关系良好,相关系数均大于0.999,方法检出限为0.005~0.16 mg/kg。采用所建方法对标准物质GBW 07403、GBW 07404和GBW 07405a进行测定,测定平均值均在标准值范围内,测定结果的相对标准偏差为2.45%~6.21%(n=12)。该方法操作简便、成本低、污染小,具有实际应用前景。 展开更多
关键词 土壤 微波消解 三重四级杆电感耦合等离子体质谱法 甲醇增敏 高灵敏嵌片
在线阅读 下载PDF
微波消解处理-三重四级杆电感耦合等离子体质谱测定土壤样品中硒量 被引量:1
17
作者 邓碧霞 《化工设计通讯》 CAS 2024年第2期137-140,共4页
土壤样品中Se含量测试时,微波消解可以充分消解样品且试剂使用量较少,测试结果同参考值相吻合,测试相对误差RE在-3.2%~-4.0%之间,RSD在2.3%~4.6%之间。三重四级杆电感耦合等离子体质谱测试土壤样品中Se时,其本身抗干扰能力较强,采用He... 土壤样品中Se含量测试时,微波消解可以充分消解样品且试剂使用量较少,测试结果同参考值相吻合,测试相对误差RE在-3.2%~-4.0%之间,RSD在2.3%~4.6%之间。三重四级杆电感耦合等离子体质谱测试土壤样品中Se时,其本身抗干扰能力较强,采用He气作为碰撞气体,采用碰撞模式时测试效果更好,测试精密度RSD在0.8%~4.6%之间,相对误差RE在-1.3%~3.8%之间。使用氧气作为碰撞气体,可以使溶液中Se离子碰撞结合成质量更大的测试目标物Se.O(98),从而进一步排除干扰,测试结果同参考值更加吻合。经实际样品测试验证,采用微波消解进行前处理,电感耦合等离子体质谱仪在氧气碰撞模式下测试土壤样品中的硒测试精密度RSD在0.8%~4.9%之间,加标回收率在96.7%~102.8%之间,方法稳定可靠。 展开更多
关键词 微波消解 三重四级杆 电感耦合等离子体质谱 土壤样品 硒量
在线阅读 下载PDF
微波消解-三重串联电感耦合等离子体质谱法同时测定大气颗粒物中重金属和稀土元素
18
作者 刘永林 周萍 +3 位作者 王佳 蔡鹏 郭洪壮 万博阳 《广州化工》 CAS 2024年第24期87-91,共5页
运用特氟龙滤膜采集样品,通过微波消解大气颗粒物,研究建立三重串联电感耦合等离子体质谱法同时测定大气颗粒物中16种重金属和16种稀土元素的方法。在MS/MS模式下,使用氦气、氧气为碰撞气/反应气,通过优化仪器参数条件,引入Rh、Ir为内... 运用特氟龙滤膜采集样品,通过微波消解大气颗粒物,研究建立三重串联电感耦合等离子体质谱法同时测定大气颗粒物中16种重金属和16种稀土元素的方法。在MS/MS模式下,使用氦气、氧气为碰撞气/反应气,通过优化仪器参数条件,引入Rh、Ir为内标元素,利用氦气原位质量、氧气原位质量和氧气质量转移,有效地克服了基体环境对待测元素的质谱干扰。研究结果表明:该方法的检出限为0.1~145 ng/L,加标回收率在90.3%~104.3%之间,测定精度(RSD)<6.0%。模拟大气颗粒物样品土壤标准物质(GBW07407a)实际测定值与推荐值一致。该方法具有试剂消耗量小、环境污染少、操作简单、检测快速、同时多元素测定等优点。为环境监测和安全风险评估提供了科学方法和理论依据。 展开更多
关键词 大气颗粒物 重金属元素 稀土元素 微波消解 三重串联电感耦合等离子体质谱
在线阅读 下载PDF
三重串联电感耦合等离子体质谱法直接测定高纯氧化钕中14种稀土杂质元素 被引量:26
19
作者 吴伟明 刘和连 郑腾飞 《分析化学》 SCIE EI CAS CSCD 北大核心 2015年第5期697-702,共6页
建立了三重串联电感耦合等离子体质谱(ICP-MS/MS)法直接测定高纯钕中的14种稀土杂质元素的方法。采用氧气和氨气反应池在串联质谱MS/MS模式,有效克服了基体对待测元素的干扰。通过优化仪器参数得到Tb,Dy和Ho的背景等效浓度分别为22,40... 建立了三重串联电感耦合等离子体质谱(ICP-MS/MS)法直接测定高纯钕中的14种稀土杂质元素的方法。采用氧气和氨气反应池在串联质谱MS/MS模式,有效克服了基体对待测元素的干扰。通过优化仪器参数得到Tb,Dy和Ho的背景等效浓度分别为22,40和4 ng/L。在选定的条件下,样品加标0.5μg/L14种混合稀土标样测得的回收率为88.6%~98.6%,使用仪器标准配置的耐高盐进样系统(HMI)测得2 h信号值的相对标准偏差(RSD)为1.3%~4.1%。本方法简单实用,能够满足纯度为5N(99.999%)及以上的高纯钕中14种杂质元素的直接测定。 展开更多
关键词 三重串联电感耦合等离子体质谱(icp-ms/ms) 高纯钕 稀土元素(REE) 干扰
在线阅读 下载PDF
ICP-MS/MS直接测定高纯Eu_2O_3中超痕量的铥、砷、硅 被引量:11
20
作者 徐芝亮 吴海燕 +1 位作者 张智怡 刘永林 《中国稀土学报》 CAS CSCD 北大核心 2016年第4期453-459,共7页
运用三重串联电感耦合等离子质谱(ICP-MS/MS)仪直接测定高纯Eu_2O_3中超痕量的Tm,As和Si。采用H_2的原位质量法和O_2质量转移法,有效克服了基体对待测元素的干扰。通过优化仪器参数得到Tm,As和Si的背景等效浓度分别为0.0005763,0.08435,... 运用三重串联电感耦合等离子质谱(ICP-MS/MS)仪直接测定高纯Eu_2O_3中超痕量的Tm,As和Si。采用H_2的原位质量法和O_2质量转移法,有效克服了基体对待测元素的干扰。通过优化仪器参数得到Tm,As和Si的背景等效浓度分别为0.0005763,0.08435,8.268μg·L^(-1)。在选定条件下,样品加标回收率为95.74%~103.82%,相对标准偏差(RSD)为0.22%~4.38%。本方法简单实用,能够满足纯度99.999%以上的高纯Eu_2O_3中杂质元素的快速测定。 展开更多
关键词 三重串联电感耦合等离子质谱(icp-ms/ms) 高纯Eu2O3 铥、砷、硅 干扰
原文传递