An ultrahigh performance liquid chromatography-triple quadrupole tandem mass spectrometry(UPLC-MS/MS)was established to quickly and accurately determine the content of oleuropein in cosmetics.The samples were extracte...An ultrahigh performance liquid chromatography-triple quadrupole tandem mass spectrometry(UPLC-MS/MS)was established to quickly and accurately determine the content of oleuropein in cosmetics.The samples were extracted with methanol-aqueous solution,and the mobile phase with methanol-formic acid solution(0.1 mol/L)=40∶60 was separated by Agilent ZORBAX Eclipse Plus C18(2.1 mm×50 mm×1.8μm-Micron)column temperature 30℃,flow rate 0.3 mL/min.The MS end was detected by electrospray negative mode ionization(ESI-)and multiple reaction monitoring(MRM)mode.The results show a good linear relationship in the range of 0.002~5 mg/L,with a correlation coefficient R2 of 0.999,5.Method recovery range from 84.2%~107.6%and the relative standard deviation RSD is 5.8%.The detection time is 5 min,the detection limit is 0.000,6 mg/L,and the limit of quantification is 0.002 mg/L.This method has the advantages of convenient operation,low quantification limit,high precision and good repeatability,and is suitable for measuring the content of oleuropein in many kinds of cosmetics.展开更多
A simultaneous method was successfully established and validated for the separation and determination of bu- prenorphine (BP), its primary metabolite, nor-buprenorphine (NBP) and a proposed co-formulate, naloxone ...A simultaneous method was successfully established and validated for the separation and determination of bu- prenorphine (BP), its primary metabolite, nor-buprenorphine (NBP) and a proposed co-formulate, naloxone (NLX) in human plasma. The method used buprenorphine-d4 (BP-D4), nor-buprenorphine-d3 (NBP-D3), naltrexone (NTX) as internal standards (ISs). 100 μL of plasma sample fortified with the ISs was cleaned up by solid-phase extraction (SPE), and was then separated on a Waters AcquityTM BEH C18 column with gradient elution using methanol and water (containing 0.2% formic) at a flow rate of 0.25 mL·min^-1. The mass spectrometer was used for detection and was operated in the positive electrospray ionization with multiple reaction monitoring (MRM) mode. The three compounds were effectively separated in 5 min. The linear ranges of the compounds were 0.1--25, 0.25--25 and 0.05--25 ng·mL^-1 for BP, NBP and NLX, respectively, with r≥0.9935. The method had high sensitivity (the lim- its of detection were 0.02, 0.1 and 0.01 ng.mL-1 for BP, NBP and NLX, respectively) and high recoveries (≥97.6%). The result was shown to be linear and satisfactorily met current acceptance criteria for validation of bio- analytical method: intra and inter assay precisions within the required limits of ≤25% RSD. The LOQs fulfilled the LOQ requirements: precision≤25% RSD, and was fully validated according to the State Food and Drug Administration (SFDA) regulations. The results demonstrated that ultra-high performance liquid chromatography- tandem mass spectrometer (UPLC-MS/MS) with SPE was a powerful detection tool and contributed to pharmaceutical analysis in biological matrices.展开更多
[目的]建立同时检测配合饲料中64种药物的超高效液相色谱-三重四极杆串联质谱(ultra-high performance liquid chromatography-triple quadrupole tandem mass spectrometry,UHPLC-MS/MS)法,提高非法添加物的检测效率。[方法]采用Waters...[目的]建立同时检测配合饲料中64种药物的超高效液相色谱-三重四极杆串联质谱(ultra-high performance liquid chromatography-triple quadrupole tandem mass spectrometry,UHPLC-MS/MS)法,提高非法添加物的检测效率。[方法]采用Waters HSS T3型色谱柱(2.1 mm×100 mm,1.8μm)进行分离,流动相A为0.1%甲酸水溶液,流动相B为含0.1%甲酸的乙腈溶液,梯度洗脱,流速为0.40 mL/min,进样量为2μL;采用电喷雾离子源正离子扫描模式进行检测,多反应监测模式进行信号采集。比较4种样品提取溶剂以及2种固相萃取柱处理对目标药物的回收率,确定样品前处理的最佳方法。利用建立的UHPLC-MS/MS法对宁夏回族自治区不同来源的100批次配合饲料样品进行64种药物检测。[结果]配合饲料样品均质后,用含0.2%甲酸的乙腈水溶液(乙腈∶水=8∶2,V/V)提取,利用Oasis PRiME HLB型固相萃取柱对样品净化,多数目标药物的回收率在60%以上。64种药物在浓度为5.0~200.0μg/L的范围内线性关系良好,相关系数(R)均大于0.99;不同药物的定量限在5.0~10.0μg/kg;阳性添加5.0、20.0、50.0μg/kg 3个浓度的平均回收率在41.00%~120.49%,批内相对标准偏差(RSD)在0.54%~15.94%,批间RSD在1.25%~13.64%。在100个批次的配合饲料样品中均未检出目标药物。[结论]建立的UHPLC-MS/MS法线性关系良好、回收率高、精密度好,具有较高的重现性和较好的可操作性,可用于配合饲料中非法添加64种药物的筛查。展开更多
文摘An ultrahigh performance liquid chromatography-triple quadrupole tandem mass spectrometry(UPLC-MS/MS)was established to quickly and accurately determine the content of oleuropein in cosmetics.The samples were extracted with methanol-aqueous solution,and the mobile phase with methanol-formic acid solution(0.1 mol/L)=40∶60 was separated by Agilent ZORBAX Eclipse Plus C18(2.1 mm×50 mm×1.8μm-Micron)column temperature 30℃,flow rate 0.3 mL/min.The MS end was detected by electrospray negative mode ionization(ESI-)and multiple reaction monitoring(MRM)mode.The results show a good linear relationship in the range of 0.002~5 mg/L,with a correlation coefficient R2 of 0.999,5.Method recovery range from 84.2%~107.6%and the relative standard deviation RSD is 5.8%.The detection time is 5 min,the detection limit is 0.000,6 mg/L,and the limit of quantification is 0.002 mg/L.This method has the advantages of convenient operation,low quantification limit,high precision and good repeatability,and is suitable for measuring the content of oleuropein in many kinds of cosmetics.
文摘A simultaneous method was successfully established and validated for the separation and determination of bu- prenorphine (BP), its primary metabolite, nor-buprenorphine (NBP) and a proposed co-formulate, naloxone (NLX) in human plasma. The method used buprenorphine-d4 (BP-D4), nor-buprenorphine-d3 (NBP-D3), naltrexone (NTX) as internal standards (ISs). 100 μL of plasma sample fortified with the ISs was cleaned up by solid-phase extraction (SPE), and was then separated on a Waters AcquityTM BEH C18 column with gradient elution using methanol and water (containing 0.2% formic) at a flow rate of 0.25 mL·min^-1. The mass spectrometer was used for detection and was operated in the positive electrospray ionization with multiple reaction monitoring (MRM) mode. The three compounds were effectively separated in 5 min. The linear ranges of the compounds were 0.1--25, 0.25--25 and 0.05--25 ng·mL^-1 for BP, NBP and NLX, respectively, with r≥0.9935. The method had high sensitivity (the lim- its of detection were 0.02, 0.1 and 0.01 ng.mL-1 for BP, NBP and NLX, respectively) and high recoveries (≥97.6%). The result was shown to be linear and satisfactorily met current acceptance criteria for validation of bio- analytical method: intra and inter assay precisions within the required limits of ≤25% RSD. The LOQs fulfilled the LOQ requirements: precision≤25% RSD, and was fully validated according to the State Food and Drug Administration (SFDA) regulations. The results demonstrated that ultra-high performance liquid chromatography- tandem mass spectrometer (UPLC-MS/MS) with SPE was a powerful detection tool and contributed to pharmaceutical analysis in biological matrices.