期刊文献+
共找到6篇文章
< 1 >
每页显示 20 50 100
Vibration control of the finite L-shaped beam structures based on the active and reactive power flow 被引量:2
1
作者 LIU ChunChuan LI FengMing +1 位作者 TANG Liang HUANG WenHu 《Science China(Physics,Mechanics & Astronomy)》 SCIE EI CAS 2011年第2期310-319,共10页
This paper analyzes the physical meaning of the active and reactive power flow in the finite L-shaped beams and studies the active vibration control of the structures based on the active and reactive power flow.The tr... This paper analyzes the physical meaning of the active and reactive power flow in the finite L-shaped beams and studies the active vibration control of the structures based on the active and reactive power flow.The traveling wave approach is used to calculate the structural dynamic responses.Because the error of control force is inevitable in practical applications,the effects of the error of control force on the control results are studied.The study indicates that the error of control force has pronounced influence on the control results of the acceleration and reactive power flow.It is obvious that the reactive power flow can represent the vibration strength component of the complex intensity,and the active power flow strongly depends on the structural damping of the finite beams. 展开更多
关键词 finite L-shaped beam active power flow reactive power flow active vibration control traveling wave method
原文传递
UPFC setting to avoid active power flow loop considering wind power uncertainty
2
作者 Shenghu LI Ting WANG 《Frontiers in Energy》 SCIE CSCD 2023年第1期165-175,共11页
The active power loop flow(APLF)may be caused by impropriate network configuration,impropriate parameter settings,and/or stochastic bus powers.The power flow controllers,e.g.,the unified power flow controller(UPFC),ma... The active power loop flow(APLF)may be caused by impropriate network configuration,impropriate parameter settings,and/or stochastic bus powers.The power flow controllers,e.g.,the unified power flow controller(UPFC),may be the reason and the solution to the loop flows.In this paper,the critical existence condition of the APLF is newly integrated into the simultaneous power flow model for the system and UPFC.Compared with the existing method of alternatively solving the simultaneous power flow and sensitivity-based approaching to the critical existing condition,the integrated power flow needs less iterations and calculation time.Besides,with wind power fluctuation,the interval power flow(IPF)is introduced into the integrated power flow,and solved with the affine Krawcyzk iteration to make sure that the range of active power setting of the UPFC not yielding the APLF.Compared with Monte Carlo simulation,the IPF has the similar accuracy but less time. 展开更多
关键词 active power loop flow(APLF) unified power flow controller(UPFC) wind power uncertainty interval power flow(IPF)
原文传递
The wave and vibratory power transmission in a finite L-shaped Mindlin plate with two simply supported opposite edges 被引量:7
3
作者 Chun-Chuan Liu Feng-Ming Li Ting-Wei Liang Wen-Hu Huang 《Acta Mechanica Sinica》 SCIE EI CAS CSCD 2011年第5期785-795,共11页
In this paper,wave and vibratory power transmission in a finite L-shaped Mindlin plate with two simply supported opposite edges are investigated using the wave approach.The dynamic responses,active and reactive power ... In this paper,wave and vibratory power transmission in a finite L-shaped Mindlin plate with two simply supported opposite edges are investigated using the wave approach.The dynamic responses,active and reactive power flow in the finite plate are calculated by the Mindlin plate theory (MPT) and classic plate theory (CPT).To satisfy the boundary conditions and continuous conditions at the coupled junction of the finite L-shaped plate,the near-field and far-field waves are entirely contained in the wave approach.The in-plane longitudinal and shear waves are also considered.The results indicate that the vibratory power flow based on the MPT is different from that based on the CPT not only at high frequencies but also at low and medium frequencies.The influence of the plate thickness on the vibrational power flow is investigated.From the results it is seen that the shear and rotary inertia correction of the MPT can influence the active and reactive power at the junction of the L-shaped plate not only at high frequencies but also at low and medium frequencies.Furthermore,the effects of structural damping on the active and reactive power flow at the junction are also analyzed. 展开更多
关键词 Finite L-shaped Mindlin plate active power flow Reactive power flow Wave approach
在线阅读 下载PDF
Intelligent Assessment of Active and ReactivePower Flow with Satisfying Accuracy forN-k_(1)-k_(2) Cascading Outages 被引量:1
4
作者 Yusheng Xue Yun Liu 《Journal of Modern Power Systems and Clean Energy》 SCIE EI CSCD 2021年第5期986-999,共14页
Addressed to the N-k_(1)-k_(2) cascading outages,it is computationally burdensome for the reliable calculation of active and reactive power flows.This paper builds a comprehensive framework with three algorithms,inclu... Addressed to the N-k_(1)-k_(2) cascading outages,it is computationally burdensome for the reliable calculation of active and reactive power flows.This paper builds a comprehensive framework with three algorithms,including the distribution factor(DF),the Newton-Raphson(NR),and the first iteration of NR algorithm(termed as 1J).Classifiers are designed to determine whether the NR algorithm should be employed for accuracy.Classifier features are extracted upon the analytical error of 1J.As reactive power is partially considered in the 1J but neglected in the DF algorithm,the deviation between the solutions is taken as one crucial feature.The support vector machine(SVM)is then utilized for classifier training.As the deep integration of the causal inference and the statistical paradigm,this framework calculates active and reactive power flows rapidly,reliably,and robustly.The effectiveness and robustness are fully validated in three typical IEEE systems. 展开更多
关键词 active power flow algorithm coordination causal algorithm integration of research paradigms N-k_(1)-k_(2)cascading outage reactive power flow
原文传递
PASSIVE-ACTIVE CONTROL OF A FLEXIBLE ISOLATION SYSTEM
5
作者 Song KongjieZhang BingSun LinglingSun YuguoSchool of Mechanical Engineering, Shandong University, Jinan 250061, China 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2003年第4期408-410,416,共4页
Passive-active control of a flexible isolation system is investigated from the viewpoint of power flow. Dynamic transfer equations of the system are deduced based on a matrix method which uses mobility or impedance re... Passive-active control of a flexible isolation system is investigated from the viewpoint of power flow. Dynamic transfer equations of the system are deduced based on a matrix method which uses mobility or impedance representations of three substructures: the source of vibration, the receiver and the mounting system which connects the source to the receiver. The cancellation of axial input forces to the receiver is considered as the active control strategy and its effects are discussed. The results of the study show that the strategy adopted herein can effectively reduce the power transmitted to the receiver. 展开更多
关键词 Flexible isolation system power flow active control
在线阅读 下载PDF
Power flow transmission in a coupled flexible system with active executive elements
6
作者 HUO Rui SHI Yin (Institute of Naval Ship Equipment Noise & Vibration, Naval University, of Engineering Wuhan 430033) SONG Kongjie (College of Mechanic Engineering, Shandong University of Technology Jinan 250061) 《Chinese Journal of Acoustics》 2002年第1期51-58,共8页
Based on its prototype of machine-isolator-foundation systems, a theoretical model for dynamic coupled linear system is established, in which both the passive and active control factors are considered. Power flow is u... Based on its prototype of machine-isolator-foundation systems, a theoretical model for dynamic coupled linear system is established, in which both the passive and active control factors are considered. Power flow is used as the cost function to evaluate the isolation effectiveness. And the transmission of vibratory power flow from a vibrating rigid body into a simply supported thin panel through passive isolators and actuators is investigated numerically. The active control strategy is summarized in the conclusion. 展开更多
关键词 flow FLEXIBLE power flow transmission in a coupled flexible system with active executive elements
原文传递