This paper presents a new technique for measuring the bunch length of a high-energy electron beam at a bunch-by-bunch rate in storage rings.This technique uses the time–frequency-domain joint analysis of the bunch si...This paper presents a new technique for measuring the bunch length of a high-energy electron beam at a bunch-by-bunch rate in storage rings.This technique uses the time–frequency-domain joint analysis of the bunch signal to obtain bunch-by-bunch and turn-by-turn longitudinal parameters,such as bunch length and synchronous phase.The bunch signal is obtained using a button electrode with a bandwidth of several gigahertz.The data acquisition device was a high-speed digital oscilloscope with a sampling rate of more than 10 GS/s,and the single-shot sampling data buffer covered thousands of turns.The bunch-length and synchronous phase information were extracted via offline calculations using Python scripts.The calibration coefficient of the system was determined using a commercial streak camera.Moreover,this technique was tested on two different storage rings and successfully captured various longitudinal transient processes during the harmonic cavity debugging process at the Shanghai Synchrotron Radiation Facility(SSRF),and longitudinal instabilities were observed during the single-bunch accumulation process at Hefei Light Source(HLS).For Gaussian-distribution bunches,the uncertainty of the bunch phase obtained using this technique was better than 0.2 ps,and the bunch-length uncertainty was better than 1 ps.The dynamic range exceeded 10 ms.This technology is a powerful and versatile beam diagnostic tool that can be conveniently deployed in high-energy electron storage rings.展开更多
In order to monitor the working state of piston motor and measure its instantaneous rotation speed accurately, the measuring principle and method of instantaneous rotation speed based on industrial personal computer a...In order to monitor the working state of piston motor and measure its instantaneous rotation speed accurately, the measuring principle and method of instantaneous rotation speed based on industrial personal computer and data acquisition card are introduced, and the major error source, influence mechanism and processing method of data quantization error are dis- cussed. By means of hybrid programming approach of LabVIEW and MATLAB, the instantaneous rotation speed measurement system for the piston motor in variable speed hydraulic system is designed. The simulation and experimental results show that the designed instantaneous speed measurement system is feasible. Furthermore, the sampling frequency has an important influ- ence on the instantaneous rotation speed measurement of piston motor and higher sampling frequency can lower quantization er- ror and improve measurement accuracy.展开更多
Lactate,as a metabolite,plays a significant role in a number of fields,including medical diagnostics,exercise physiology and food science.Traditional methods for lactate measurement often involve expensive and cumbers...Lactate,as a metabolite,plays a significant role in a number of fields,including medical diagnostics,exercise physiology and food science.Traditional methods for lactate measurement often involve expensive and cumbersome instrumentation.This study developed a portable and low-cost lactate measurement system,including independently detectable hardware circuits and user-friendly embedded software,computer,and smartphone applications.The experiment verified that the relative error of the detection current in the device circuit was less than 1%.The electrochemical performance was measured by comparing the[Fe(CN)_(6)]^(3−)/[Fe(CN)_(6)]^(4−)solution with the desktop electrochemical workstation CHI660E,and a nearly consistent chronoamperometry(CA)curve was obtained.Two modified lactate sensors were used for CA testing of lactate.Within the concentration range of 0.1 mmol·L^(−1)to 20 mmol·L^(−1),there was a good linear relationship between lactate concentration and steady-state current,with a correlation coefficient(R2)greater than 0.99 and good repeatability,demonstrating the reliability of the developed device.The lactate measurement system developed in this study not only provides excellent detection performance and reliability,but also achieves portability and low cost,providing a new solution for lactate measurement.展开更多
Gyrnnarchus niloticus swims by undulations of a long-based dorsal fin, while its body axis is in many cases held straight during swimming. This paper provides a brief relevant introduction to Gyrnnarchus niloticus, wh...Gyrnnarchus niloticus swims by undulations of a long-based dorsal fin, while its body axis is in many cases held straight during swimming. This paper provides a brief relevant introduction to Gyrnnarchus niloticus, which belongs to the African freshwater electric eels but can inspire our bionic interests in propulsion besides its abilities in electric sensing. A special larva of Gyrnnarchus niloticus was morphologically measured by photographing it with a piece of scale-calibrated paper as the background. Then we analyzed the data by a CFD-aided approach. Detailed flow patterns around the larva and a NACA0012 hydrofoil were respectively calculated and visualized at the Reynolds number of 7350 or so. The results show that the profile of Gyrnnarchus niloticus is well streamlined.展开更多
The venturi meter has an advantage in its use,because it can measure flow without being much affected by the type of the measured fluid or flow conditions.Hence,it has excellent versatility and is being widely applied...The venturi meter has an advantage in its use,because it can measure flow without being much affected by the type of the measured fluid or flow conditions.Hence,it has excellent versatility and is being widely applied in many industries.The flow of a liquid containing air is a representative example of a multiphase flow and exhibits complex flow characteristics.In particular,the greater the gas volume fraction(GVF),the more inhomogeneous the flow becomes.As a result,using a venturi meter to measure the rate of a flow that has a high GVF generates an error.In this study,the cause of the error occurred in measuring the flow rate for the multiphase flow when using the venturi meter for analysis by CFD.To ensure the reliability of this study,the accuracy of the multiphase flow models for numerical analysis was verified through comparison between the calculated results of numerical analysis and the experimental data.As a result,the Grace model,which is a multiphase flow model established by an experiment with water and air,was confirmed to have the highest reliability.Finally,the characteristics of the internal flow Held about the multiphase flow analysis result generated by applying the Grace model were analyzed to find the cause of the uncertainty occurring when measuring the flow rate of the multiphase flow using the venturi meter.A phase separation phenomenon occurred due to a density difference of water and air inside the venturi,and flow inhomogeneity happened according to the flow velocity difference of each phase.It was confirmed that this flow inhomogeneity increased as the GVF increased due to the uncertainty of the flow measurement.展开更多
The measurement uncertainty provides complete information about an analytical result. This is very important because several decisions of compliance or non-compliance are based on analytical results in pharmaceutical ...The measurement uncertainty provides complete information about an analytical result. This is very important because several decisions of compliance or non-compliance are based on analytical results in pharmaceutical industries. The aim of this work was to evaluate and discuss the estimation of uncertainty in pharmaceutical analysis. The uncertainty is a useful tool in the assessment of compliance or non-compliance of in-process and final pharmaceutical products as well as in the assessment of pharmaceutical equivalence and stability study of drug products.展开更多
The deformation and residual stress generated by the welding process can seriously affect the use of components.As a result,it is very important to understand the evolution of stress and strain during the welding proc...The deformation and residual stress generated by the welding process can seriously affect the use of components.As a result,it is very important to understand the evolution of stress and strain during the welding process.The strain measurement method based on digital image correlation(DIC)is an excellent method to detect welding strain and residual stress.The out-of-plane translation and out-of-plane rotation introduce errors to the two-dimensional DIC.In this paper,the causes of errors are analyzed theoretically,and the formulas of errors caused by the out-of-plane displacement and the out-of-plane rotation are derived.The out-of-plane translation experiment and the out-of-plane rotation experiment were carried out to verify the theory,and the experimental results are consistent with the theoretical analysis results.The error caused by the out-of-plane translation can be reduced by increasing the object distance;the error caused by the out-of-plane rotation is greatly affected by the rotation angle.展开更多
Workflow logs that record the execution of business processes offer very valuable data resource for real-time enterprise performance measurement. In this paper, a novel scheme that uses the technology of data warehous...Workflow logs that record the execution of business processes offer very valuable data resource for real-time enterprise performance measurement. In this paper, a novel scheme that uses the technology of data warehouse and OLAP to explore workflow logs and create complex analysis reports for enterprise performance measurement is proposed. Three key points of this scheme are studied: 1) the measure set; 2) the open and flexible architecture for workflow logs analysis system; 3) the data models in WFMS and data warehouse. A case study that shows the validity of the scheme is also provided.展开更多
The radiation damage of three individual subcells for GalnP/GaAs//Ge triple-junction solar cells irradiated with electrons and protons is investigated using photoluminescence (PL) measurements. The PL spectra of eac...The radiation damage of three individual subcells for GalnP/GaAs//Ge triple-junction solar cells irradiated with electrons and protons is investigated using photoluminescence (PL) measurements. The PL spectra of each subcell are obtained using different excitation lasers. The PL intensity has a fast degradation after irradiation, and decreases as the displacement damage dose increases. Furthermore, the normalized PL intensity varying with the displacement damage dose is analyzed in detail, and then the lifetime damage coefficients of the recombination centers for GaInP top-cell, GaAs mid-cell and Ge bottom-cell of the triple-junction solar cells are determined from the PL radiative efficiency.展开更多
This paper analyzes current spectrum utilization from all aspects based on related methods of spectrum measurement. The measurement results show that some spectrum resources are not used effectively due to current fix...This paper analyzes current spectrum utilization from all aspects based on related methods of spectrum measurement. The measurement results show that some spectrum resources are not used effectively due to current fixed spectrum allocation policy, and the spectrum occupancy varies dramatically in terms of time and space. These results provide basis for the development of next generation wireless communication technologies such as Cognitive Radio (CR).展开更多
A fully superconducting electron cyclotron resonance (ECR) ion source (SECRAL ID is currently being built in the Institute of Modern Physics, Chinese Academy of Sciences. Its key components are three superconductin...A fully superconducting electron cyclotron resonance (ECR) ion source (SECRAL ID is currently being built in the Institute of Modern Physics, Chinese Academy of Sciences. Its key components are three superconducting solenoids (Nb-Ti/Cu) and six superconducting sextupoles (Nb-Ti/Cu). Different from the conventional supercon- ducting ECR magnetic structure, the SEC17AL Ⅱ includes three superconducting solenoid coils' that are located inside the superconducting sextupoles. The SECRAL Ⅱ can significantly reduce the interaction forces between the sextupole and the solenoids, and the magnets can also be more compact in size. For this multi-component SECRAL Ⅱ generating its self field of -8 T and being often exposed to the high self field, the mechanical analysis has become the main issue to keep their stress at 〈200 MPa on coils. The analytical and experimental results in mechanics are presented in the SECRAL Ⅱ structure. To improve the accuracy and efficiency of analysis, according to the composite rule of micromechanics, the equivalent uniform windings are used to simulate the epoxy-impregnated Nb-Ti/Cu coils. In addition, using low temperature strain gauges and a wireless fast strain acquisition system, a fundamental experiment on the based on our analysis, the stresses and deformations optimized. strains developments of a sextupole is reported. Finally, for its assembly of each SECRAL Ⅱ coil will be further展开更多
The fast and maximum thermal neutron fluxes from the DD-109 neutron generator at the University of Sharjah were experimentally measured by the activation technique using different neutron reactions. The thermal and fa...The fast and maximum thermal neutron fluxes from the DD-109 neutron generator at the University of Sharjah were experimentally measured by the activation technique using different neutron reactions. The thermal and fast neutron fluxes were found to be 2.960 × 10~6 and6.186 × 10~7 n/cm^2 s, respectively. This was done to verify the modeling results for the optimum moderator thickness needed to maximize the thermal neutron flux. The optimum moderator thickness was found to be between 3.5 and4 cm. The present data were compared with the detailed MCNP model-based calculation performed in earlier work to simulate the generator.展开更多
In the current waste gas sampling of fixed source,it is required that deviation of tracking rate of constant velocity sampling should not be more than 10%.When flow rate of the waste gas is less than 5 m/s,the trackin...In the current waste gas sampling of fixed source,it is required that deviation of tracking rate of constant velocity sampling should not be more than 10%.When flow rate of the waste gas is less than 5 m/s,the tracking rate can not meet this requirement.The sampling of fixed velocity can meet the requirement of particulate matter sampling on gas collection volume at low velocity.Through the comparison of two different methods for the determination of particulate matter in waste gas under the low flow velocity of flue gas,it was found that there were some differences between the fixed velocity measurement and the constant velocity measurement.The results showed that measurement result of the fixed velocity was higher than that of constant velocity measurement under low velocity.At the same time,the deviation of fixed velocity measurement was not obvious under different low velocity.展开更多
One hundred fifty three mandibles of adult Chinese cadavers were measured. The acquired data were correlatively analysed with computer. It was found that bigonial breadth (EE’) was correlated with the breadth between...One hundred fifty three mandibles of adult Chinese cadavers were measured. The acquired data were correlatively analysed with computer. It was found that bigonial breadth (EE’) was correlated with the breadth between bilateral canines (BB’), the bimentalbreite (CC’) and the breadth between right and left vertex of alveolar ridge between the first and the second molar (DD’). The length of mandibular body (AF) was strongly correlated with the vertical distance from bigonial breadth to the breadth of bilateral canines (BB’F), to the bimentalbreite (CC’F) and to the breadth between right and left vertex of alveolar ridge between the first and the second molar (DD’F). Six regressive equations were established. Significance of these equations was discussed.展开更多
ISO9001:2000 and TS 16949 have become the major quality system management models in present traditional and Hi-tech industries. The Measurement System Analysis (MSA) Reference Manual, on the other hand, is one of the ...ISO9001:2000 and TS 16949 have become the major quality system management models in present traditional and Hi-tech industries. The Measurement System Analysis (MSA) Reference Manual, on the other hand, is one of the core tools in ISO/TS 16949. MSA aims to evaluate Gauge Repeatability and Reproducibility (GR&R) where the control, monitoring, and maintenance of the measurement process are required in measurement systems so that the measurement capability could be ensured under statistical control. An ideal measurement system should present the statistical characteristic of zero error on any measured product. Nevertheless, such an ideal measurement system hardly exists. Managers therefore have to adopt such measurement systems with unsatisfactory statistical characteristics. Traditional MSA indexes are constructed with definite observed values. Nevertheless, measurements with observed values are not entirely error-free. For this reason, this study proposes to research three cases in a case company and apply the integration of Fuzzy Theory and GR&R to discuss the differences in the evaluation index GR&R and the Number of Distinct Categories (NDC). Substituting fuzzy numbers for definite numbers found that the data of %GR&R were increased and NDC was decreased after fuzzification. Such results verify that the fuzzified %GR&R and NDC become stricter in the determination criterion. The research outcomes could assist the case company in improving the reference data of measurement systems and promoting the measurement quality.展开更多
With determination micro-Fe by 1, 10-phenanthroline spectrophotometry for example, they are systematically introduced the combinatorial measurement and regression analysis method application about metheodic principle,...With determination micro-Fe by 1, 10-phenanthroline spectrophotometry for example, they are systematically introduced the combinatorial measurement and regression analysis method application about metheodic principle, operation step and data processing in the instrumental analysis, including: calibration curve best linear equation is set up, measurand best linear equation is set up, and calculation of best value of a concentration. The results showed that mean of thrice determination , s = 0 μg/mL, RSD = 0. Results of preliminary application are simply introduced in the basic instrumental analysis for atomic absorption spectrophotometry, ion-selective electrodes, coulometry and polarographic analysis and are contrasted to results of normal measurements.展开更多
The area which is being studied is located in northwest of Isfahan, 30 kilometers south of Kashan, and southern section of Qmasar. The longitude of the area of study is 51°19'13"E to 51°26'26&qu...The area which is being studied is located in northwest of Isfahan, 30 kilometers south of Kashan, and southern section of Qmasar. The longitude of the area of study is 51°19'13"E to 51°26'26"E and its latitude is 33°34'24"N to 33°44'24"N. Based on microscopic observations, modal analysis, and also based on their location in the Streckeisen [QAPF], both the stones of the Qohrud batholitic mass themselves and its enclaves are more in quartz monzonite ranges. Granitoid also have quartz monzonite enclaves. These enclaves are from both microgranular mafic and Autolith types which indicate the mixing of two magmas. At the center of the pluton, there are indications of existence of main magma reservoir and magma mixing. In terms of mineralogy, the granitoid rocks of the area very much resemble I-type. The zoning of the plagioclases is both the normal kind and variation invert and has andesine general composition. The probed biotite sample contains iron and belongs to a granitic sample from the center of the mass. Also, the ranking graph indicates biotite as the source of recrystallization for the analyzed points. The probed biotite sample of the Qohrud area showed formation temperature of 730 degrees centigrade. According to the Rb and Sr contents, the source of the rocks is at depths of 20 to 30 kilometers from the earth’s surface that are depending on the subduction zone. The formation temperature of the specimens of the Qohrud batholithic mass is mostly between 900 to 1000 degrees centigrade. [At] the center of the mass (around Qahrud), the amount of molybdenum is higher than the economic limit.展开更多
In this paper, the method of vibration measurement and modal analysis for AM50 Tunneller machine is presented. When the machine was used for cutting man made coal bed and real coal bed, the vibration of the machine wa...In this paper, the method of vibration measurement and modal analysis for AM50 Tunneller machine is presented. When the machine was used for cutting man made coal bed and real coal bed, the vibration of the machine was measured and the results of signal analysis show that the vibration characteristics under the two kinds of working situations are similar. The modal model of the machine is established, and then, the intrinsic vibration characteristics of AM50 tunneller are investigated by means of the method of experimental modal analysis. The vibration response simulation under a set of loading spectra measured is carried out by force response simulation software.展开更多
To detect overlapped echoes due to the thin pavement layers,we present a thickness measurement approach for the very thin layer of pavement structures.The term "thin" is relative to the incident wavelength o...To detect overlapped echoes due to the thin pavement layers,we present a thickness measurement approach for the very thin layer of pavement structures.The term "thin" is relative to the incident wavelength or pulse.By means of independent component analysis of noisy signals received by a single radar sensor,the overlapped echoes can be successfully separated.Once the echoes from the top and bottom side of a thin layer have been separated,the time delay and the layer thickness determination follow immediately.Results of the simulation and real data verify the feasibility of the presented method.展开更多
基金supported by the National Key R&D Program(No.2022YFA1602201)。
文摘This paper presents a new technique for measuring the bunch length of a high-energy electron beam at a bunch-by-bunch rate in storage rings.This technique uses the time–frequency-domain joint analysis of the bunch signal to obtain bunch-by-bunch and turn-by-turn longitudinal parameters,such as bunch length and synchronous phase.The bunch signal is obtained using a button electrode with a bandwidth of several gigahertz.The data acquisition device was a high-speed digital oscilloscope with a sampling rate of more than 10 GS/s,and the single-shot sampling data buffer covered thousands of turns.The bunch-length and synchronous phase information were extracted via offline calculations using Python scripts.The calibration coefficient of the system was determined using a commercial streak camera.Moreover,this technique was tested on two different storage rings and successfully captured various longitudinal transient processes during the harmonic cavity debugging process at the Shanghai Synchrotron Radiation Facility(SSRF),and longitudinal instabilities were observed during the single-bunch accumulation process at Hefei Light Source(HLS).For Gaussian-distribution bunches,the uncertainty of the bunch phase obtained using this technique was better than 0.2 ps,and the bunch-length uncertainty was better than 1 ps.The dynamic range exceeded 10 ms.This technology is a powerful and versatile beam diagnostic tool that can be conveniently deployed in high-energy electron storage rings.
基金National Natural Science Foundation of China(No.51275375,No.51509006)Shaanxi Provincial Natural Science Basic Research Plan(No.2014JQ7246)+1 种基金The Science and Technology of Hubei Province(No.B2015115)Doctoral Research Foundation of Hubei University of Automotive Technology(No.BK201403)
文摘In order to monitor the working state of piston motor and measure its instantaneous rotation speed accurately, the measuring principle and method of instantaneous rotation speed based on industrial personal computer and data acquisition card are introduced, and the major error source, influence mechanism and processing method of data quantization error are dis- cussed. By means of hybrid programming approach of LabVIEW and MATLAB, the instantaneous rotation speed measurement system for the piston motor in variable speed hydraulic system is designed. The simulation and experimental results show that the designed instantaneous speed measurement system is feasible. Furthermore, the sampling frequency has an important influ- ence on the instantaneous rotation speed measurement of piston motor and higher sampling frequency can lower quantization er- ror and improve measurement accuracy.
基金supported by National Natural Science Foundation of China(No.62006092)Natural Science Research Project of Anhui Educational Committee(No.2023AH030081)+1 种基金2023 New Era Education Provincial Quality Engineering Project(Graduate Education)(No.2023cxcysj103)2024 New Era Education Provincial Quality Engineering Project(Graduate Education)。
文摘Lactate,as a metabolite,plays a significant role in a number of fields,including medical diagnostics,exercise physiology and food science.Traditional methods for lactate measurement often involve expensive and cumbersome instrumentation.This study developed a portable and low-cost lactate measurement system,including independently detectable hardware circuits and user-friendly embedded software,computer,and smartphone applications.The experiment verified that the relative error of the detection current in the device circuit was less than 1%.The electrochemical performance was measured by comparing the[Fe(CN)_(6)]^(3−)/[Fe(CN)_(6)]^(4−)solution with the desktop electrochemical workstation CHI660E,and a nearly consistent chronoamperometry(CA)curve was obtained.Two modified lactate sensors were used for CA testing of lactate.Within the concentration range of 0.1 mmol·L^(−1)to 20 mmol·L^(−1),there was a good linear relationship between lactate concentration and steady-state current,with a correlation coefficient(R2)greater than 0.99 and good repeatability,demonstrating the reliability of the developed device.The lactate measurement system developed in this study not only provides excellent detection performance and reliability,but also achieves portability and low cost,providing a new solution for lactate measurement.
文摘Gyrnnarchus niloticus swims by undulations of a long-based dorsal fin, while its body axis is in many cases held straight during swimming. This paper provides a brief relevant introduction to Gyrnnarchus niloticus, which belongs to the African freshwater electric eels but can inspire our bionic interests in propulsion besides its abilities in electric sensing. A special larva of Gyrnnarchus niloticus was morphologically measured by photographing it with a piece of scale-calibrated paper as the background. Then we analyzed the data by a CFD-aided approach. Detailed flow patterns around the larva and a NACA0012 hydrofoil were respectively calculated and visualized at the Reynolds number of 7350 or so. The results show that the profile of Gyrnnarchus niloticus is well streamlined.
基金supported by the Industrial Infrastructure Program through The Korea Institute for Advancement of Technology(KIAT) Grant funded by the Korea government Ministry of Trade,Industry and Energy(Grant N0000502)
文摘The venturi meter has an advantage in its use,because it can measure flow without being much affected by the type of the measured fluid or flow conditions.Hence,it has excellent versatility and is being widely applied in many industries.The flow of a liquid containing air is a representative example of a multiphase flow and exhibits complex flow characteristics.In particular,the greater the gas volume fraction(GVF),the more inhomogeneous the flow becomes.As a result,using a venturi meter to measure the rate of a flow that has a high GVF generates an error.In this study,the cause of the error occurred in measuring the flow rate for the multiphase flow when using the venturi meter for analysis by CFD.To ensure the reliability of this study,the accuracy of the multiphase flow models for numerical analysis was verified through comparison between the calculated results of numerical analysis and the experimental data.As a result,the Grace model,which is a multiphase flow model established by an experiment with water and air,was confirmed to have the highest reliability.Finally,the characteristics of the internal flow Held about the multiphase flow analysis result generated by applying the Grace model were analyzed to find the cause of the uncertainty occurring when measuring the flow rate of the multiphase flow using the venturi meter.A phase separation phenomenon occurred due to a density difference of water and air inside the venturi,and flow inhomogeneity happened according to the flow velocity difference of each phase.It was confirmed that this flow inhomogeneity increased as the GVF increased due to the uncertainty of the flow measurement.
基金supported by Fundacao de Apoio à Pesquisa do Estado de Sao Paulo(FAPESP)
文摘The measurement uncertainty provides complete information about an analytical result. This is very important because several decisions of compliance or non-compliance are based on analytical results in pharmaceutical industries. The aim of this work was to evaluate and discuss the estimation of uncertainty in pharmaceutical analysis. The uncertainty is a useful tool in the assessment of compliance or non-compliance of in-process and final pharmaceutical products as well as in the assessment of pharmaceutical equivalence and stability study of drug products.
文摘The deformation and residual stress generated by the welding process can seriously affect the use of components.As a result,it is very important to understand the evolution of stress and strain during the welding process.The strain measurement method based on digital image correlation(DIC)is an excellent method to detect welding strain and residual stress.The out-of-plane translation and out-of-plane rotation introduce errors to the two-dimensional DIC.In this paper,the causes of errors are analyzed theoretically,and the formulas of errors caused by the out-of-plane displacement and the out-of-plane rotation are derived.The out-of-plane translation experiment and the out-of-plane rotation experiment were carried out to verify the theory,and the experimental results are consistent with the theoretical analysis results.The error caused by the out-of-plane translation can be reduced by increasing the object distance;the error caused by the out-of-plane rotation is greatly affected by the rotation angle.
文摘Workflow logs that record the execution of business processes offer very valuable data resource for real-time enterprise performance measurement. In this paper, a novel scheme that uses the technology of data warehouse and OLAP to explore workflow logs and create complex analysis reports for enterprise performance measurement is proposed. Three key points of this scheme are studied: 1) the measure set; 2) the open and flexible architecture for workflow logs analysis system; 3) the data models in WFMS and data warehouse. A case study that shows the validity of the scheme is also provided.
基金Supported by the National Natural Science Foundation of China under Grant Nos 10675023,11075018,11375028 and 11675020the Specialized Research Fund for the Doctoral Program of Higher Education under Grant No 20120003110011
文摘The radiation damage of three individual subcells for GalnP/GaAs//Ge triple-junction solar cells irradiated with electrons and protons is investigated using photoluminescence (PL) measurements. The PL spectra of each subcell are obtained using different excitation lasers. The PL intensity has a fast degradation after irradiation, and decreases as the displacement damage dose increases. Furthermore, the normalized PL intensity varying with the displacement damage dose is analyzed in detail, and then the lifetime damage coefficients of the recombination centers for GaInP top-cell, GaAs mid-cell and Ge bottom-cell of the triple-junction solar cells are determined from the PL radiative efficiency.
文摘This paper analyzes current spectrum utilization from all aspects based on related methods of spectrum measurement. The measurement results show that some spectrum resources are not used effectively due to current fixed spectrum allocation policy, and the spectrum occupancy varies dramatically in terms of time and space. These results provide basis for the development of next generation wireless communication technologies such as Cognitive Radio (CR).
基金Supported by the National Natural Science Foundation of China under Grant No 11302225the China Postdoctoral Science Foundation under Grant Nos 2014M560820 and 2015T81071
文摘A fully superconducting electron cyclotron resonance (ECR) ion source (SECRAL ID is currently being built in the Institute of Modern Physics, Chinese Academy of Sciences. Its key components are three superconducting solenoids (Nb-Ti/Cu) and six superconducting sextupoles (Nb-Ti/Cu). Different from the conventional supercon- ducting ECR magnetic structure, the SEC17AL Ⅱ includes three superconducting solenoid coils' that are located inside the superconducting sextupoles. The SECRAL Ⅱ can significantly reduce the interaction forces between the sextupole and the solenoids, and the magnets can also be more compact in size. For this multi-component SECRAL Ⅱ generating its self field of -8 T and being often exposed to the high self field, the mechanical analysis has become the main issue to keep their stress at 〈200 MPa on coils. The analytical and experimental results in mechanics are presented in the SECRAL Ⅱ structure. To improve the accuracy and efficiency of analysis, according to the composite rule of micromechanics, the equivalent uniform windings are used to simulate the epoxy-impregnated Nb-Ti/Cu coils. In addition, using low temperature strain gauges and a wireless fast strain acquisition system, a fundamental experiment on the based on our analysis, the stresses and deformations optimized. strains developments of a sextupole is reported. Finally, for its assembly of each SECRAL Ⅱ coil will be further
文摘The fast and maximum thermal neutron fluxes from the DD-109 neutron generator at the University of Sharjah were experimentally measured by the activation technique using different neutron reactions. The thermal and fast neutron fluxes were found to be 2.960 × 10~6 and6.186 × 10~7 n/cm^2 s, respectively. This was done to verify the modeling results for the optimum moderator thickness needed to maximize the thermal neutron flux. The optimum moderator thickness was found to be between 3.5 and4 cm. The present data were compared with the detailed MCNP model-based calculation performed in earlier work to simulate the generator.
基金Supported by the Shihezi Science and Technology Plan(2018JZ08)the National Natural Science Foundation of China(21667026)
文摘In the current waste gas sampling of fixed source,it is required that deviation of tracking rate of constant velocity sampling should not be more than 10%.When flow rate of the waste gas is less than 5 m/s,the tracking rate can not meet this requirement.The sampling of fixed velocity can meet the requirement of particulate matter sampling on gas collection volume at low velocity.Through the comparison of two different methods for the determination of particulate matter in waste gas under the low flow velocity of flue gas,it was found that there were some differences between the fixed velocity measurement and the constant velocity measurement.The results showed that measurement result of the fixed velocity was higher than that of constant velocity measurement under low velocity.At the same time,the deviation of fixed velocity measurement was not obvious under different low velocity.
文摘One hundred fifty three mandibles of adult Chinese cadavers were measured. The acquired data were correlatively analysed with computer. It was found that bigonial breadth (EE’) was correlated with the breadth between bilateral canines (BB’), the bimentalbreite (CC’) and the breadth between right and left vertex of alveolar ridge between the first and the second molar (DD’). The length of mandibular body (AF) was strongly correlated with the vertical distance from bigonial breadth to the breadth of bilateral canines (BB’F), to the bimentalbreite (CC’F) and to the breadth between right and left vertex of alveolar ridge between the first and the second molar (DD’F). Six regressive equations were established. Significance of these equations was discussed.
文摘ISO9001:2000 and TS 16949 have become the major quality system management models in present traditional and Hi-tech industries. The Measurement System Analysis (MSA) Reference Manual, on the other hand, is one of the core tools in ISO/TS 16949. MSA aims to evaluate Gauge Repeatability and Reproducibility (GR&R) where the control, monitoring, and maintenance of the measurement process are required in measurement systems so that the measurement capability could be ensured under statistical control. An ideal measurement system should present the statistical characteristic of zero error on any measured product. Nevertheless, such an ideal measurement system hardly exists. Managers therefore have to adopt such measurement systems with unsatisfactory statistical characteristics. Traditional MSA indexes are constructed with definite observed values. Nevertheless, measurements with observed values are not entirely error-free. For this reason, this study proposes to research three cases in a case company and apply the integration of Fuzzy Theory and GR&R to discuss the differences in the evaluation index GR&R and the Number of Distinct Categories (NDC). Substituting fuzzy numbers for definite numbers found that the data of %GR&R were increased and NDC was decreased after fuzzification. Such results verify that the fuzzified %GR&R and NDC become stricter in the determination criterion. The research outcomes could assist the case company in improving the reference data of measurement systems and promoting the measurement quality.
文摘With determination micro-Fe by 1, 10-phenanthroline spectrophotometry for example, they are systematically introduced the combinatorial measurement and regression analysis method application about metheodic principle, operation step and data processing in the instrumental analysis, including: calibration curve best linear equation is set up, measurand best linear equation is set up, and calculation of best value of a concentration. The results showed that mean of thrice determination , s = 0 μg/mL, RSD = 0. Results of preliminary application are simply introduced in the basic instrumental analysis for atomic absorption spectrophotometry, ion-selective electrodes, coulometry and polarographic analysis and are contrasted to results of normal measurements.
文摘The area which is being studied is located in northwest of Isfahan, 30 kilometers south of Kashan, and southern section of Qmasar. The longitude of the area of study is 51°19'13"E to 51°26'26"E and its latitude is 33°34'24"N to 33°44'24"N. Based on microscopic observations, modal analysis, and also based on their location in the Streckeisen [QAPF], both the stones of the Qohrud batholitic mass themselves and its enclaves are more in quartz monzonite ranges. Granitoid also have quartz monzonite enclaves. These enclaves are from both microgranular mafic and Autolith types which indicate the mixing of two magmas. At the center of the pluton, there are indications of existence of main magma reservoir and magma mixing. In terms of mineralogy, the granitoid rocks of the area very much resemble I-type. The zoning of the plagioclases is both the normal kind and variation invert and has andesine general composition. The probed biotite sample contains iron and belongs to a granitic sample from the center of the mass. Also, the ranking graph indicates biotite as the source of recrystallization for the analyzed points. The probed biotite sample of the Qohrud area showed formation temperature of 730 degrees centigrade. According to the Rb and Sr contents, the source of the rocks is at depths of 20 to 30 kilometers from the earth’s surface that are depending on the subduction zone. The formation temperature of the specimens of the Qohrud batholithic mass is mostly between 900 to 1000 degrees centigrade. [At] the center of the mass (around Qahrud), the amount of molybdenum is higher than the economic limit.
文摘In this paper, the method of vibration measurement and modal analysis for AM50 Tunneller machine is presented. When the machine was used for cutting man made coal bed and real coal bed, the vibration of the machine was measured and the results of signal analysis show that the vibration characteristics under the two kinds of working situations are similar. The modal model of the machine is established, and then, the intrinsic vibration characteristics of AM50 tunneller are investigated by means of the method of experimental modal analysis. The vibration response simulation under a set of loading spectra measured is carried out by force response simulation software.
文摘To detect overlapped echoes due to the thin pavement layers,we present a thickness measurement approach for the very thin layer of pavement structures.The term "thin" is relative to the incident wavelength or pulse.By means of independent component analysis of noisy signals received by a single radar sensor,the overlapped echoes can be successfully separated.Once the echoes from the top and bottom side of a thin layer have been separated,the time delay and the layer thickness determination follow immediately.Results of the simulation and real data verify the feasibility of the presented method.