In this paper,to present a lightweight-developed front underrun protection device(FUPD)for heavy-duty trucks,plain weave carbon fiber reinforced plastic(CFRP)is used instead of the original high-strength steel.First,t...In this paper,to present a lightweight-developed front underrun protection device(FUPD)for heavy-duty trucks,plain weave carbon fiber reinforced plastic(CFRP)is used instead of the original high-strength steel.First,the mechanical and structural properties of plain carbon fiber composite anti-collision beams are comparatively analyzed from a multi-scale perspective.For studying the design capability of carbon fiber composite materials,we investigate the effects of TC-33 carbon fiber diameter(D),fiber yarn width(W)and height(H),and fiber yarn density(N)on the front underrun protective beam of carbon fiber compositematerials.Based on the investigation,a material-structure matching strategy suitable for the front underrun protective beam of heavy-duty trucks is proposed.Next,the composite material structure is optimized by applying size optimization and stack sequence optimization methods to obtain the higher performance carbon fiber composite front underrun protection beam of commercial vehicles.The results show that the fiber yarn height(H)has the greatest influence on the protective beam,and theH1matching scheme for the front underrun protective beamwith a carbon fiber composite structure exhibits superior performance.The proposed method achieves a weight reduction of 55.21% while still meeting regulatory requirements,which demonstrates its remarkable weight reduction effect.展开更多
This paper analyzed the reliability and put forward the reliability index of overload protection for moulded case circuit breaker. The success rate was adopted as its reliability index of overload protection. Based on...This paper analyzed the reliability and put forward the reliability index of overload protection for moulded case circuit breaker. The success rate was adopted as its reliability index of overload protection. Based on the reliability index and the reli- ability level, the reliability examination plan was analyzed and a test device for the overload protection of moulded case cir- cuit-breaker was developed. In the reliability test of overload protection, two power sources were used, which reduced the time of conversion and regulation between two different test currents in the overload protection test, which made the characteristic test more accurate. The test device was designed on the base of a Windows system, which made its operation simple and friendly.展开更多
Objective: The beneficial effect of percutaneous coronary intervention (PCI) in patients with acute myocardial infarction (AMI) has been well established, but there is the problem of no-reflow phenomenon which is an a...Objective: The beneficial effect of percutaneous coronary intervention (PCI) in patients with acute myocardial infarction (AMI) has been well established, but there is the problem of no-reflow phenomenon which is an adverse prognostic factor in primary PCI. In the present study the effect of a distal protection device (PercuSurge GuardWire; GW) on epicardial blood flow and myocardial perfusion was evaluated. Methods and Results: Patients with AMI were randomly divided into 2 groups, the GW and the control groups. The GW group included 52 patients with AMI who underwent primary PCI with GW protection and the control group included 60 patients who underwent primary PCI without GW protection. Epicardial blood flow in the infarct-related artery (IRA) and myocardial perfusion were evaluated according to the thrombolysis in myocardial infarction (TIMI) flow grade and the myocardial blush grade (MBG). We found TIMI score of 3 was obtained significantly more frequently in the GW group (96%) than in the control group (80%). The MBG score of 3 was obtained also significantly greater in the GW group (65%) than in the control group (33%). Conclusion: Primary PCI with GW protection can significantly improve epicardial blood flow and myocardial perfusion.展开更多
The reliability analysis of vertically integrated protection devices is crucial for designing International Electrotechnical Commission(IEC)61850-based substations.This paper presents the hardware architecture of a fo...The reliability analysis of vertically integrated protection devices is crucial for designing International Electrotechnical Commission(IEC)61850-based substations.This paper presents the hardware architecture of a four-inone vertically integrated device and the information transmission path of each function based on the functional information transmission chain of protection devices,measurement and control devices,merging units,and intelligent terminals.Additionally,a reliability analysis model of the protection device and its protection system is constructed using the fault tree analysis method while considering the characteristics of each module of the vertically integrated device.The stability probability of the protection system in each state is analyzed by combining the state-transfer equations of line and busbar protection with a Markov chain.Finally,the failure rate and availability of the protection device and its protection system are calculated under different ambient temperatures using a 110 kV intelligent substation as an example.The sensitivity of each device module is analyzed.展开更多
The article discusses the possibility of further modernization of the standard microprocessor relay protection of AC overhead system feeders DPA-27.5-TNF, which is operated on the Trans-Baikal Railway by creating an a...The article discusses the possibility of further modernization of the standard microprocessor relay protection of AC overhead system feeders DPA-27.5-TNF, which is operated on the Trans-Baikal Railway by creating an additional automated system of unified templates necessary for the occurrence of “trainability” elements. The templates will be formed via a separate dedicated channel for transmission, processing and storage of the necessary information, not related to the operation of the terminal, with its subsequent visualization at the workplace of the duty personnel of traction substations, together with information from the “GID” software received via another dedicated wired channel. With the help of such a base of unified preset templates, in the future, it will be possible not only to identify the specific causes of each emergency shutdown but also to reduce their number by dynamically adjusting the existing presets of the standard operation algorithm.展开更多
Objective The trial was designed to evaluate the safety and performance of the ev3 Protégé TM stent in the treatment of de novo or re-stenotic common and/or internal carotid artery stenoses with adjunctive u...Objective The trial was designed to evaluate the safety and performance of the ev3 Protégé TM stent in the treatment of de novo or re-stenotic common and/or internal carotid artery stenoses with adjunctive use of a CE-marked filter embolic protection device.Methods This study was a prospective multi-center, single-arm trial. Between June and October 2003, 77 patients were enrolled in 8 investigational centers throughout Europe. The primary endpoint was the incidence of Major Neurological Events (MANE) through one month. Other endpoints were the ability to properly place the stent, and primary patency and MANE after six months. Eligible for the study were patients with a de novo or restenotic target lesion located in the common and/or internal carotid artery (>70% stenosis for asymptomatic and >50% stenosis for symptomatic patients). The ev3 Spider (Embolic Protection Filter was used in 75 of 77 cases. Results In 76 out of the 77 patients (99%), the stent could be successfully implanted with a residual stenosis ≤30% as criterion. Of the 74 patients that had a carotid ultrasound at one month follow-up, none had a re-stenosis of the target lesion. There were three MANEs during or immediately after the procedure (3.9%), two were major and one was a minor stroke. There were eight severe complications (9.1%); six of these happened during or immediately after the procedure and were related to the procedure, none was related to the device. They are resolved without sequelae. No deaths have occurred.Conclusions The Protégé stent is safe and performs well in the treatment of carotid artery stenosis. The technical success rate for placement of the Protégé stent as assessed by the residual stenosis post implant was very high and all stents were successfully deployed. The incidence of MANE was comparable with that in other recent carotid stent studies and still lower than standard CEA.展开更多
To enhance encoding efficiency, an unequal error protection (UEP) broadcast scheme based on one additional feedback is proposed. Different from the equal probability selection for source packets in traditional fount...To enhance encoding efficiency, an unequal error protection (UEP) broadcast scheme based on one additional feedback is proposed. Different from the equal probability selection for source packets in traditional fountain encoding, the proposed scheme calculates the packet loss ratio (PLR) according to the feedback results in systematic broadcast phase (SBP) and then optimizes the selection probability for source packets to guarantee higher level error protection for those source packets with larger PLRs. Thus the amount of unnecessarily redundant encoded packets during encoding broadcast phase (EBP) is decreased significantly. Numerical results show that the proposed scheme can recover 60% more packets than the traditional non-feedback broadcast scheme at the ex- pense of tolerably only one feedback procedure.展开更多
In addition to the conventional Franklin Rod,many non-conventional air terminals are being used as lightning protection devices.As cited in previous works,these non-conventional devices emit space charge in the vicini...In addition to the conventional Franklin Rod,many non-conventional air terminals are being used as lightning protection devices.As cited in previous works,these non-conventional devices emit space charge in the vicinity of the terminals during the process of lightning stroke.A number of factors affect the performance of these lightning protection devices,among them are geometry and dimension of the devices,location of the device above the ground,height of the cloud above the ground,and polarity of the lightning stroke.The performance of these lightning protection devices has been a topic of discussion by researchers for many years.Some studies focused on the magnitude of emission current from these devices as a criterion to evaluate their performances.The critical flashover voltage(CFO)between the devices and a metal screen simulating cloud can also be used as another criterion to evaluate the performance of the devices.Laboratory measurements were conducted in controlled conditions on different types of lightning protection devices to compare their performance.Four different types of devices were used in the present study:Franklin Rod,TerraStat models TS 100,TS 400,and Spline Ball Ionizer.The study focused on the CFO voltage of the air gap between devices and the metal screen.The CFO voltage was evaluated using standard switching and lightning impulses.The measurements were recorded for positive as well as negative polarity.The air gap between the devices and metal screen was selected at 2 m and 3 m.The results obtained provide a better understanding of the electrical performance of lightning protection devices.展开更多
As the power electronics technology is widely used in the power system, it may also bring the DC component to the transformer operation, resulting in DC bias and may cause great harm to the transformer. In this articl...As the power electronics technology is widely used in the power system, it may also bring the DC component to the transformer operation, resulting in DC bias and may cause great harm to the transformer. In this article, the device to protect transformer from DC magnetic bias is designed. On the basis of load DC current, a magnetic bias protection device is developed by combination of current sensor, electric information collection circuit, signal filtering circuit, signal modulating circuits, fault feature judging circuit, automatic range tracking circuit, intelligent logic synthesis unit and implementation output circuit. By operating in temperature-rise test equipment in the high power electronic lab, the device is proved with reliability, high sensitivity and worthy of promotion and application.展开更多
In this work, we show that an excessive lattice heating problem can occur in the diode electrostatic discharge (ESD) protection device connected to a V<sub>DD</sub> bus in the popular diode input prot...In this work, we show that an excessive lattice heating problem can occur in the diode electrostatic discharge (ESD) protection device connected to a V<sub>DD</sub> bus in the popular diode input protection scheme, which is favorably used in CMOS RF ICs. To figure out the reason for the excessive lattice heating, we construct an equivalent circuit for input human-body model (HBM) test environment of a CMOS chip equipped with the diode protection circuit, and execute mixed-mode transient simulations utilizing a 2-D device simulator. We analyze the simulation results in detail to show out that a parasitic pnp bipolar transistor action relating nearby p<sup>+</sup>-substrate contacts is responsible for the excessive lattice heating in the diode protection device, which has never been focused before anywhere.展开更多
Belt conveyor is a kind of important equipment for transporting coal mines, and is also a facility for connecting various processes. It plays a vital role in the supply of raw materials. At present, people have used b...Belt conveyor is a kind of important equipment for transporting coal mines, and is also a facility for connecting various processes. It plays a vital role in the supply of raw materials. At present, people have used belt conveyors in the mining, production, transportation and processing processes of coal mines. It not only has a large transportation volume, but also can be applied in complex working environments. The equipment has a strong carrying capacity and supports transportation by the Bureau of Parks and Roads. This paper gives an overview and analysis of the material blocking protection device of belt conveyor, looking for a proximity switch, combining with the problems encountered in the test, and based on the working principle of belt conveyor, puts forward effective improvement measures of the device, increasing the weight of the detection door in the transformation, and improving the use efficiency.展开更多
Power grid equipment maintenance is a high safety work, and its primary task is the installation and implementation of grounding device, and grounding line to the maintenance of power engineering construction personne...Power grid equipment maintenance is a high safety work, and its primary task is the installation and implementation of grounding device, and grounding line to the maintenance of power engineering construction personnel life safety has played a very good role. This paper firstly analyzes the shortcomings of the existing grounding line device, puts forward the pain points of climbing the rod to turn the maintenance, and the unreliable and unqualified grounding line cannot well protect the safety of the line personnel, the environmental requirements for the maintenance (triple rod, rod body slippery, cross crossing). Based on relevant research and analysis, propose a new electromechanical control grounding wire error prevention device design scheme. The product consists of upper, middle and lowers;the upper wire in a safe and reliable way and the middle with the hoop and beam base way, the bottom of the upper wire and the ground wire on the bottom can switch from cold standby to maintenance. The upper part is composed of diversion wire clips and diversion wires. There is a blade in the middle, used to prevent mis-action and its role is to meet the needs of insulation. The bottom is installed with insulated ground flat iron and laid a ground net on the ground to ensure the personal safety of the staff.展开更多
In recent years, microelectronic components are more widely used in relay protection devices, but most of the electronic devices are electronic sensitive devices, which are easy to be affected by interference. When th...In recent years, microelectronic components are more widely used in relay protection devices, but most of the electronic devices are electronic sensitive devices, which are easy to be affected by interference. When the relay protection devices are interfered in the power system, if there is a fault, it will affect the overall security of the power grid, resulting in the power grid cannot operate stably. When the interference energy exceeds the maximum allowable energy of the logic circuit, it will directly damage the components and affect the normal operation of the relay protection device. Therefore, strengthening the anti-interference ability of relay protection and automation devices has become an important topic in power system.展开更多
As the main base of China's electricity production, power plants are of self-evident importance. But in the power plant, has many equipment, these equipment has provided the safeguard for the power plant normal op...As the main base of China's electricity production, power plants are of self-evident importance. But in the power plant, has many equipment, these equipment has provided the safeguard for the power plant normal operation. As an important equipment in the power plant, relay protection device has its existence, which can ensure the safety of the power plant during its operation. Therefore, in the actual work, it is necessary to improve the power plant relay protection device maintenance and management capabilities, so that relay protection devices can better provide security for the power plant. Based on this, this paper takes the power plant relay protection device as the breakthrough point, and puts forward some measures for its daily maintenance and management, hoping to improve the operation ability of the power plant relay protection device, and also play a role in promoting the normal operation of the power plant.展开更多
Because of their economy and applicability,high-power thyristor devices are widely used in the power supply systems for large fusion devices.When high-dose neutrons produced by deuterium–tritium(D–T)fusion reactions...Because of their economy and applicability,high-power thyristor devices are widely used in the power supply systems for large fusion devices.When high-dose neutrons produced by deuterium–tritium(D–T)fusion reactions are irradiated on a thyristor device for a long time,the electrical characteristics of the device change,which may eventually cause irreversible damage.In this study,with the thyristor switch of the commutation circuit in the quench protection system(QPS)of a fusion device as the study object,the relationship between the internal physical structure and external electrical parameters of the irradiated thyristor is established.Subsequently,a series of targeted thyristor physical simulations and neutron irradiation experiments are conducted to verify the accuracy of the theoretical analysis.In addition,the effect of irradiated thyristor electrical characteristic changes on the entire QPS is studied by accurate simulation,providing valuable guidelines for the maintenance and renovation of the QPS.展开更多
In this paper, the extreme wave loads on an on-shore wave power device are investigated. First, boundary element method is applied to solve the three dimensional potential problem based on the small amplitude wave ass...In this paper, the extreme wave loads on an on-shore wave power device are investigated. First, boundary element method is applied to solve the three dimensional potential problem based on the small amplitude wave assumption. Then the motion of the Oscillating Water Column (OWC) inside the device and its laods on the device are calculated in time domain. Several protective techniques often applied are simulated by changing the constraint of the upper end of the chamber of the device. Numerical results are used to judge the effectiveness of these techniques. The investigation shows that damping can not effectively restrain the motion of OWC when the period of incident wave is long, which may cause dangerous loads on the structure. The shut chamber can effectively restrain the motion of OWC, but alternatively cause high pressure in the chamber. A Contracting opening with a Taper (CT) can exhaust a great amount of kinetic energy of OWC, and significantly decrease the loads. It is a promising protective technique.展开更多
An embedded protective device for 35kV power line is worked out based on Philips’ LPC2292 ARM MCU. Several aspects such as embedded design technique adopted in the system framework, application of adaptive theory in ...An embedded protective device for 35kV power line is worked out based on Philips’ LPC2292 ARM MCU. Several aspects such as embedded design technique adopted in the system framework, application of adaptive theory in data acquisition, Board Support Packet (BSP) developing and task dispatching related to operating system are discussed. Both hardware and software framework of the system are given. Advanced hardware platform and software development environment is applied in design of the system, with the advanced co-design technology.展开更多
Purpose: This research aims to evaluate the potential threats to patient privacy and confidentiality posed by mHealth applications on mobile devices. Methodology: A comprehensive literature review was conducted, selec...Purpose: This research aims to evaluate the potential threats to patient privacy and confidentiality posed by mHealth applications on mobile devices. Methodology: A comprehensive literature review was conducted, selecting eighty-eight articles published over the past fifteen years. The study assessed data gathering and storage practices, regulatory adherence, legal structures, consent procedures, user education, and strategies to mitigate risks. Results: The findings reveal significant advancements in technologies designed to safeguard privacy and facilitate the widespread use of mHealth apps. However, persistent ethical issues related to privacy remain largely unchanged despite these technological strides.展开更多
This paper proposes to study the coordination of protective devices when 8 MW synchronous generators are interconnected to distribution System of PEA. The coordination between recloser and drop out fuse is investigate...This paper proposes to study the coordination of protective devices when 8 MW synchronous generators are interconnected to distribution System of PEA. The coordination between recloser and drop out fuse is investigated in this paper. The three-phase fault is simulated using digital simulation and electrical network calculation program (DIgSILENT). The results are shown that the short circuit current from substation is reduced comparing to the distribution system without DG connected. It causes to protective device coordination inconsistently, so the maintenance will be delayed more than expected.展开更多
基金supported by the Guangxi Science and Technology Plan and Project(Grant Numbers 2021AC19131 and 2022AC21140)Guangxi University of Science and Technology Doctoral Fund Project(Grant Number 20Z40).
文摘In this paper,to present a lightweight-developed front underrun protection device(FUPD)for heavy-duty trucks,plain weave carbon fiber reinforced plastic(CFRP)is used instead of the original high-strength steel.First,the mechanical and structural properties of plain carbon fiber composite anti-collision beams are comparatively analyzed from a multi-scale perspective.For studying the design capability of carbon fiber composite materials,we investigate the effects of TC-33 carbon fiber diameter(D),fiber yarn width(W)and height(H),and fiber yarn density(N)on the front underrun protective beam of carbon fiber compositematerials.Based on the investigation,a material-structure matching strategy suitable for the front underrun protective beam of heavy-duty trucks is proposed.Next,the composite material structure is optimized by applying size optimization and stack sequence optimization methods to obtain the higher performance carbon fiber composite front underrun protection beam of commercial vehicles.The results show that the fiber yarn height(H)has the greatest influence on the protective beam,and theH1matching scheme for the front underrun protective beamwith a carbon fiber composite structure exhibits superior performance.The proposed method achieves a weight reduction of 55.21% while still meeting regulatory requirements,which demonstrates its remarkable weight reduction effect.
基金Project (No. E2005000039) supported by the Natural Science Foun-dation of Hebei Province, China
文摘This paper analyzed the reliability and put forward the reliability index of overload protection for moulded case circuit breaker. The success rate was adopted as its reliability index of overload protection. Based on the reliability index and the reli- ability level, the reliability examination plan was analyzed and a test device for the overload protection of moulded case cir- cuit-breaker was developed. In the reliability test of overload protection, two power sources were used, which reduced the time of conversion and regulation between two different test currents in the overload protection test, which made the characteristic test more accurate. The test device was designed on the base of a Windows system, which made its operation simple and friendly.
文摘Objective: The beneficial effect of percutaneous coronary intervention (PCI) in patients with acute myocardial infarction (AMI) has been well established, but there is the problem of no-reflow phenomenon which is an adverse prognostic factor in primary PCI. In the present study the effect of a distal protection device (PercuSurge GuardWire; GW) on epicardial blood flow and myocardial perfusion was evaluated. Methods and Results: Patients with AMI were randomly divided into 2 groups, the GW and the control groups. The GW group included 52 patients with AMI who underwent primary PCI with GW protection and the control group included 60 patients who underwent primary PCI without GW protection. Epicardial blood flow in the infarct-related artery (IRA) and myocardial perfusion were evaluated according to the thrombolysis in myocardial infarction (TIMI) flow grade and the myocardial blush grade (MBG). We found TIMI score of 3 was obtained significantly more frequently in the GW group (96%) than in the control group (80%). The MBG score of 3 was obtained also significantly greater in the GW group (65%) than in the control group (33%). Conclusion: Primary PCI with GW protection can significantly improve epicardial blood flow and myocardial perfusion.
基金supported by the 2020 Infrastructure Engineering Technology Innovation Projectthe“Intelligent Substation”Supporting Technology Research Project(031200WS22200001)。
文摘The reliability analysis of vertically integrated protection devices is crucial for designing International Electrotechnical Commission(IEC)61850-based substations.This paper presents the hardware architecture of a four-inone vertically integrated device and the information transmission path of each function based on the functional information transmission chain of protection devices,measurement and control devices,merging units,and intelligent terminals.Additionally,a reliability analysis model of the protection device and its protection system is constructed using the fault tree analysis method while considering the characteristics of each module of the vertically integrated device.The stability probability of the protection system in each state is analyzed by combining the state-transfer equations of line and busbar protection with a Markov chain.Finally,the failure rate and availability of the protection device and its protection system are calculated under different ambient temperatures using a 110 kV intelligent substation as an example.The sensitivity of each device module is analyzed.
文摘The article discusses the possibility of further modernization of the standard microprocessor relay protection of AC overhead system feeders DPA-27.5-TNF, which is operated on the Trans-Baikal Railway by creating an additional automated system of unified templates necessary for the occurrence of “trainability” elements. The templates will be formed via a separate dedicated channel for transmission, processing and storage of the necessary information, not related to the operation of the terminal, with its subsequent visualization at the workplace of the duty personnel of traction substations, together with information from the “GID” software received via another dedicated wired channel. With the help of such a base of unified preset templates, in the future, it will be possible not only to identify the specific causes of each emergency shutdown but also to reduce their number by dynamically adjusting the existing presets of the standard operation algorithm.
文摘Objective The trial was designed to evaluate the safety and performance of the ev3 Protégé TM stent in the treatment of de novo or re-stenotic common and/or internal carotid artery stenoses with adjunctive use of a CE-marked filter embolic protection device.Methods This study was a prospective multi-center, single-arm trial. Between June and October 2003, 77 patients were enrolled in 8 investigational centers throughout Europe. The primary endpoint was the incidence of Major Neurological Events (MANE) through one month. Other endpoints were the ability to properly place the stent, and primary patency and MANE after six months. Eligible for the study were patients with a de novo or restenotic target lesion located in the common and/or internal carotid artery (>70% stenosis for asymptomatic and >50% stenosis for symptomatic patients). The ev3 Spider (Embolic Protection Filter was used in 75 of 77 cases. Results In 76 out of the 77 patients (99%), the stent could be successfully implanted with a residual stenosis ≤30% as criterion. Of the 74 patients that had a carotid ultrasound at one month follow-up, none had a re-stenosis of the target lesion. There were three MANEs during or immediately after the procedure (3.9%), two were major and one was a minor stroke. There were eight severe complications (9.1%); six of these happened during or immediately after the procedure and were related to the procedure, none was related to the device. They are resolved without sequelae. No deaths have occurred.Conclusions The Protégé stent is safe and performs well in the treatment of carotid artery stenosis. The technical success rate for placement of the Protégé stent as assessed by the residual stenosis post implant was very high and all stents were successfully deployed. The incidence of MANE was comparable with that in other recent carotid stent studies and still lower than standard CEA.
基金Supported by China National S&T Major Project(2013ZX03003002003)the National Natural Science Foundation of China(61371075)"111"Project of China(B14010)
文摘To enhance encoding efficiency, an unequal error protection (UEP) broadcast scheme based on one additional feedback is proposed. Different from the equal probability selection for source packets in traditional fountain encoding, the proposed scheme calculates the packet loss ratio (PLR) according to the feedback results in systematic broadcast phase (SBP) and then optimizes the selection probability for source packets to guarantee higher level error protection for those source packets with larger PLRs. Thus the amount of unnecessarily redundant encoded packets during encoding broadcast phase (EBP) is decreased significantly. Numerical results show that the proposed scheme can recover 60% more packets than the traditional non-feedback broadcast scheme at the ex- pense of tolerably only one feedback procedure.
文摘In addition to the conventional Franklin Rod,many non-conventional air terminals are being used as lightning protection devices.As cited in previous works,these non-conventional devices emit space charge in the vicinity of the terminals during the process of lightning stroke.A number of factors affect the performance of these lightning protection devices,among them are geometry and dimension of the devices,location of the device above the ground,height of the cloud above the ground,and polarity of the lightning stroke.The performance of these lightning protection devices has been a topic of discussion by researchers for many years.Some studies focused on the magnitude of emission current from these devices as a criterion to evaluate their performances.The critical flashover voltage(CFO)between the devices and a metal screen simulating cloud can also be used as another criterion to evaluate the performance of the devices.Laboratory measurements were conducted in controlled conditions on different types of lightning protection devices to compare their performance.Four different types of devices were used in the present study:Franklin Rod,TerraStat models TS 100,TS 400,and Spline Ball Ionizer.The study focused on the CFO voltage of the air gap between devices and the metal screen.The CFO voltage was evaluated using standard switching and lightning impulses.The measurements were recorded for positive as well as negative polarity.The air gap between the devices and metal screen was selected at 2 m and 3 m.The results obtained provide a better understanding of the electrical performance of lightning protection devices.
文摘As the power electronics technology is widely used in the power system, it may also bring the DC component to the transformer operation, resulting in DC bias and may cause great harm to the transformer. In this article, the device to protect transformer from DC magnetic bias is designed. On the basis of load DC current, a magnetic bias protection device is developed by combination of current sensor, electric information collection circuit, signal filtering circuit, signal modulating circuits, fault feature judging circuit, automatic range tracking circuit, intelligent logic synthesis unit and implementation output circuit. By operating in temperature-rise test equipment in the high power electronic lab, the device is proved with reliability, high sensitivity and worthy of promotion and application.
文摘In this work, we show that an excessive lattice heating problem can occur in the diode electrostatic discharge (ESD) protection device connected to a V<sub>DD</sub> bus in the popular diode input protection scheme, which is favorably used in CMOS RF ICs. To figure out the reason for the excessive lattice heating, we construct an equivalent circuit for input human-body model (HBM) test environment of a CMOS chip equipped with the diode protection circuit, and execute mixed-mode transient simulations utilizing a 2-D device simulator. We analyze the simulation results in detail to show out that a parasitic pnp bipolar transistor action relating nearby p<sup>+</sup>-substrate contacts is responsible for the excessive lattice heating in the diode protection device, which has never been focused before anywhere.
文摘Belt conveyor is a kind of important equipment for transporting coal mines, and is also a facility for connecting various processes. It plays a vital role in the supply of raw materials. At present, people have used belt conveyors in the mining, production, transportation and processing processes of coal mines. It not only has a large transportation volume, but also can be applied in complex working environments. The equipment has a strong carrying capacity and supports transportation by the Bureau of Parks and Roads. This paper gives an overview and analysis of the material blocking protection device of belt conveyor, looking for a proximity switch, combining with the problems encountered in the test, and based on the working principle of belt conveyor, puts forward effective improvement measures of the device, increasing the weight of the detection door in the transformation, and improving the use efficiency.
文摘Power grid equipment maintenance is a high safety work, and its primary task is the installation and implementation of grounding device, and grounding line to the maintenance of power engineering construction personnel life safety has played a very good role. This paper firstly analyzes the shortcomings of the existing grounding line device, puts forward the pain points of climbing the rod to turn the maintenance, and the unreliable and unqualified grounding line cannot well protect the safety of the line personnel, the environmental requirements for the maintenance (triple rod, rod body slippery, cross crossing). Based on relevant research and analysis, propose a new electromechanical control grounding wire error prevention device design scheme. The product consists of upper, middle and lowers;the upper wire in a safe and reliable way and the middle with the hoop and beam base way, the bottom of the upper wire and the ground wire on the bottom can switch from cold standby to maintenance. The upper part is composed of diversion wire clips and diversion wires. There is a blade in the middle, used to prevent mis-action and its role is to meet the needs of insulation. The bottom is installed with insulated ground flat iron and laid a ground net on the ground to ensure the personal safety of the staff.
文摘In recent years, microelectronic components are more widely used in relay protection devices, but most of the electronic devices are electronic sensitive devices, which are easy to be affected by interference. When the relay protection devices are interfered in the power system, if there is a fault, it will affect the overall security of the power grid, resulting in the power grid cannot operate stably. When the interference energy exceeds the maximum allowable energy of the logic circuit, it will directly damage the components and affect the normal operation of the relay protection device. Therefore, strengthening the anti-interference ability of relay protection and automation devices has become an important topic in power system.
文摘As the main base of China's electricity production, power plants are of self-evident importance. But in the power plant, has many equipment, these equipment has provided the safeguard for the power plant normal operation. As an important equipment in the power plant, relay protection device has its existence, which can ensure the safety of the power plant during its operation. Therefore, in the actual work, it is necessary to improve the power plant relay protection device maintenance and management capabilities, so that relay protection devices can better provide security for the power plant. Based on this, this paper takes the power plant relay protection device as the breakthrough point, and puts forward some measures for its daily maintenance and management, hoping to improve the operation ability of the power plant relay protection device, and also play a role in promoting the normal operation of the power plant.
基金supported by the Fundamental Research Funds for the Central University(No.JZ2023HGTA0182)Comprehensive Research Facility for Fusion Technology Program of China(No.2018-000052-73-01-001228)。
文摘Because of their economy and applicability,high-power thyristor devices are widely used in the power supply systems for large fusion devices.When high-dose neutrons produced by deuterium–tritium(D–T)fusion reactions are irradiated on a thyristor device for a long time,the electrical characteristics of the device change,which may eventually cause irreversible damage.In this study,with the thyristor switch of the commutation circuit in the quench protection system(QPS)of a fusion device as the study object,the relationship between the internal physical structure and external electrical parameters of the irradiated thyristor is established.Subsequently,a series of targeted thyristor physical simulations and neutron irradiation experiments are conducted to verify the accuracy of the theoretical analysis.In addition,the effect of irradiated thyristor electrical characteristic changes on the entire QPS is studied by accurate simulation,providing valuable guidelines for the maintenance and renovation of the QPS.
文摘In this paper, the extreme wave loads on an on-shore wave power device are investigated. First, boundary element method is applied to solve the three dimensional potential problem based on the small amplitude wave assumption. Then the motion of the Oscillating Water Column (OWC) inside the device and its laods on the device are calculated in time domain. Several protective techniques often applied are simulated by changing the constraint of the upper end of the chamber of the device. Numerical results are used to judge the effectiveness of these techniques. The investigation shows that damping can not effectively restrain the motion of OWC when the period of incident wave is long, which may cause dangerous loads on the structure. The shut chamber can effectively restrain the motion of OWC, but alternatively cause high pressure in the chamber. A Contracting opening with a Taper (CT) can exhaust a great amount of kinetic energy of OWC, and significantly decrease the loads. It is a promising protective technique.
文摘An embedded protective device for 35kV power line is worked out based on Philips’ LPC2292 ARM MCU. Several aspects such as embedded design technique adopted in the system framework, application of adaptive theory in data acquisition, Board Support Packet (BSP) developing and task dispatching related to operating system are discussed. Both hardware and software framework of the system are given. Advanced hardware platform and software development environment is applied in design of the system, with the advanced co-design technology.
文摘Purpose: This research aims to evaluate the potential threats to patient privacy and confidentiality posed by mHealth applications on mobile devices. Methodology: A comprehensive literature review was conducted, selecting eighty-eight articles published over the past fifteen years. The study assessed data gathering and storage practices, regulatory adherence, legal structures, consent procedures, user education, and strategies to mitigate risks. Results: The findings reveal significant advancements in technologies designed to safeguard privacy and facilitate the widespread use of mHealth apps. However, persistent ethical issues related to privacy remain largely unchanged despite these technological strides.
文摘This paper proposes to study the coordination of protective devices when 8 MW synchronous generators are interconnected to distribution System of PEA. The coordination between recloser and drop out fuse is investigated in this paper. The three-phase fault is simulated using digital simulation and electrical network calculation program (DIgSILENT). The results are shown that the short circuit current from substation is reduced comparing to the distribution system without DG connected. It causes to protective device coordination inconsistently, so the maintenance will be delayed more than expected.