随着国内柔性直流输电技术的快速发展,基于真双极接线的多端柔性输电技术将被越来越多地应用到实际工程中。不同于单极线路或换流器退出运行时,伪双极系统下会出现的线路过载和切机切负荷现象,对于运行方式更为灵活的真双极系统,由于非...随着国内柔性直流输电技术的快速发展,基于真双极接线的多端柔性输电技术将被越来越多地应用到实际工程中。不同于单极线路或换流器退出运行时,伪双极系统下会出现的线路过载和切机切负荷现象,对于运行方式更为灵活的真双极系统,由于非故障极可转代故障极的部分功率,使得电网可靠性和整体输电能力的提升成为可能。提出了一种适用于真双极多端柔性直流输电(VSC-MTDC)系统的功率转代策略:基于真双极系统正负极电网可独立控制功率的特点,当直流系统在非正常运行状况下出现非对称拓扑时,在确保各元件不越限的前提下使非故障极电网转代故障极电网部分功率,以提高VSC-MTDC系统的总传输容量。同时,基于张北±500 k V柔性直流输电示范工程,搭建了真双极四端柔性直流输电PSCAD/EMTDC仿真系统,对所提策略进行了有效性验证。展开更多
In order to overcome the problems of power flow control and fault current limiting in multi-terminal high voltage direct current(MTDC)grids,this paper proposes a modular multi-terminal DC power flow controller(MM-DCPF...In order to overcome the problems of power flow control and fault current limiting in multi-terminal high voltage direct current(MTDC)grids,this paper proposes a modular multi-terminal DC power flow controller(MM-DCPFC)with fault current limiting function.The topology structure,operation principle,and equivalent circuit of MM-DCPFC are introduced,and such a structure has the advantages of modularity and scalability.The power balance mechanism is studied and a hierarchical power balance control strategy is proposed.The results show that MM-DCPFC can achieve internal power exchange,which avoids the use of external power supply.The fault characteristics of MM-DCPFC are analyzed,fault current limiting and self-protection methods are proposed,and the factors affecting the current limiting capability are studied.The simulation models are established in PLECS,and the simulation results verify the effectiveness of MM-DCPFC in power flow control,fault current limiting,and scalability.In addition,a prototype is developed to validate the function and control method of MM-DCPFC.展开更多
功率-电压下垂控制策略无需站间通信,可拓展性和可靠性较高,广泛应用于模块化多电平换流器多端柔性直流输电(modular multilevel converter multi-terminal direct current transmission,MMC-MTDC)系统中,但其电压质量容易受功率波动影...功率-电压下垂控制策略无需站间通信,可拓展性和可靠性较高,广泛应用于模块化多电平换流器多端柔性直流输电(modular multilevel converter multi-terminal direct current transmission,MMC-MTDC)系统中,但其电压质量容易受功率波动影响、直流电压偏差较大,不利于系统的安全稳定运行。针对这一问题,提出了一种不平衡功率可调节范围的量化分析方法。通过构建多端柔直系统小信号模型,推导电网内不平衡功率与直流电压偏差间的传递函数表达式。基于奇异值分解(singular value decomposition,SVD)和频域分析,分别从稳态和动态角度分析下垂控制规律,以允许的最大直流电压偏差为增益边界,计算得出允许的功率调节极限。算例分析和仿真验证表明:所提方法能够有效量化评估下垂控制的功率调节范围,为MTDC系统的安全稳定运行提供指导依据。展开更多
Multi-terminal direct current(MTDC)grids provide the possibility of meshed interconnections between regional power systems and various renewable energy resources to boost supply reliability and economy.The modular mul...Multi-terminal direct current(MTDC)grids provide the possibility of meshed interconnections between regional power systems and various renewable energy resources to boost supply reliability and economy.The modular multilevel converter(MMC)has become the basic building block for MTDC and DC grids due to its salient features,i.e.,modularity and scalability.Therefore,the MMC-based MTDC systems should be pervasively embedded into the present power system to improve system performance.However,several technical challenges hamper their practical applications and deployment,including modeling,control,and protection of the MMC-MTDC grids.This paper presents a comprehensive investigation and reference in modeling,control,and protection of the MMC-MTDC grids.A general overview of state-of-the-art modeling techniques of the MMC along with their performance in simulation analysis for MTDC applications is provided.A review of control strategies of the MMC-MTDC grids which provide AC system support is presented.State-of-the art protection techniques of the MMCMTDC systems are also investigated.Finally,the associated research challenges and trends are highlighted.展开更多
This paper investigates a control and protection strategy for a four-terminal modular multilevel converter(MMC)based high-voltage direct current(HVDC)system under a converter-side AC fault.Based on the system operatin...This paper investigates a control and protection strategy for a four-terminal modular multilevel converter(MMC)based high-voltage direct current(HVDC)system under a converter-side AC fault.Based on the system operating condition,a control and protection strategy against the fault with normal blocking of the converter is proposed.In practical,applications encountering such a fault,the MMC at the fault side may experience different conditions of blocking failure.The blocking failures may occur on:①the whole converter;②one converter arm;③one sub-module(SM)/several SMs of one converter arm;④other conditions.The phenomenon of the multi-terminal HVDC(MTDC)system following the fault is analyzed under the first three conditions with real-time simulations using the real-time digital simulator(RTDS).Based on the impact of different conditions on the MTDC system,the necessity of utilizing special control and protection is discussed.A special control and protection strategy is proposed for emergency conditions,and its effectiveness is verified by real-time simulation results.展开更多
Featuring low communication requirements and high reliability,the voltage droop control method is widely adopted in the voltage source converter based multi-terminal direct current(VSC-MTDC)system for autonomous DC vo...Featuring low communication requirements and high reliability,the voltage droop control method is widely adopted in the voltage source converter based multi-terminal direct current(VSC-MTDC)system for autonomous DC voltage regulation and power-sharing.However,the traditional voltage droop control method with fixed droop gain is criticized for over-limit DC voltage deviation in case of large power disturbances,which can threaten stable operation of the entire VSCMTDC system.To tackle this problem,this paper proposes an adaptive reference power based voltage droop control method,which changes the reference power to compensate the power deviation for droop-controlled voltage source converters(VSCs).Besides retaining the merits of the traditional voltage droop control method,both DC voltage deviation reduction and power distribution improvement can be achieved by utilizing local information and a specific control factor in the proposed method.Basic principles and key features of the proposed method are described.Detailed analyses on the effects of the control factor on DC voltage deviation and imbalanced power-sharing are discussed,and the selection principle of the control factor is proposed.Finally,the effectiveness of the proposed method is validated by the simulations on a five-terminal VSC based high-voltage direct current(VSC-HVDC)system.展开更多
With the increasing use of renewable resources and electric vehicles(EVs), the variability and uncertainty in their nature put forward a high requirement for flexibility in AC distribution system incorporating voltage...With the increasing use of renewable resources and electric vehicles(EVs), the variability and uncertainty in their nature put forward a high requirement for flexibility in AC distribution system incorporating voltage source converter(VSC) based multi-terminal direct current(MTDC) grids. In order to improve the capability of distribution systems to cope with uncertainty, the flexibility enhancement of AC-MTDC distribution systems considering aggregated EVs is studied. Firstly, the charging and discharging model of one EV is proposed considering the users' demand difference and traveling needs. Based on this, a vehicle-to-grid(V2G) control strategy for aggregated EVs to participate in the flexibility promotion of distribution systems is provided. After that, an optimal flexible dispatching method is proposed to improve the flexibility of power systems through cooperation of VSCs, controllable distributed generations(CDGs), aggregated EVs, and energy storage systems(ESSs). Finally, a case study of an AC-MTDC distribution system is carried out. Simulation results show that the proposed dispatching method is capable of effectively enhancing the system flexibility, reducing renewable power curtailment, decreasing load abandonment, and cutting down system cost.展开更多
文摘随着国内柔性直流输电技术的快速发展,基于真双极接线的多端柔性输电技术将被越来越多地应用到实际工程中。不同于单极线路或换流器退出运行时,伪双极系统下会出现的线路过载和切机切负荷现象,对于运行方式更为灵活的真双极系统,由于非故障极可转代故障极的部分功率,使得电网可靠性和整体输电能力的提升成为可能。提出了一种适用于真双极多端柔性直流输电(VSC-MTDC)系统的功率转代策略:基于真双极系统正负极电网可独立控制功率的特点,当直流系统在非正常运行状况下出现非对称拓扑时,在确保各元件不越限的前提下使非故障极电网转代故障极电网部分功率,以提高VSC-MTDC系统的总传输容量。同时,基于张北±500 k V柔性直流输电示范工程,搭建了真双极四端柔性直流输电PSCAD/EMTDC仿真系统,对所提策略进行了有效性验证。
基金supported in part by National Key R&D Program of China(No.2018YFB0904600)National Natural Science Foundation of China(No.51807053)。
文摘In order to overcome the problems of power flow control and fault current limiting in multi-terminal high voltage direct current(MTDC)grids,this paper proposes a modular multi-terminal DC power flow controller(MM-DCPFC)with fault current limiting function.The topology structure,operation principle,and equivalent circuit of MM-DCPFC are introduced,and such a structure has the advantages of modularity and scalability.The power balance mechanism is studied and a hierarchical power balance control strategy is proposed.The results show that MM-DCPFC can achieve internal power exchange,which avoids the use of external power supply.The fault characteristics of MM-DCPFC are analyzed,fault current limiting and self-protection methods are proposed,and the factors affecting the current limiting capability are studied.The simulation models are established in PLECS,and the simulation results verify the effectiveness of MM-DCPFC in power flow control,fault current limiting,and scalability.In addition,a prototype is developed to validate the function and control method of MM-DCPFC.
文摘功率-电压下垂控制策略无需站间通信,可拓展性和可靠性较高,广泛应用于模块化多电平换流器多端柔性直流输电(modular multilevel converter multi-terminal direct current transmission,MMC-MTDC)系统中,但其电压质量容易受功率波动影响、直流电压偏差较大,不利于系统的安全稳定运行。针对这一问题,提出了一种不平衡功率可调节范围的量化分析方法。通过构建多端柔直系统小信号模型,推导电网内不平衡功率与直流电压偏差间的传递函数表达式。基于奇异值分解(singular value decomposition,SVD)和频域分析,分别从稳态和动态角度分析下垂控制规律,以允许的最大直流电压偏差为增益边界,计算得出允许的功率调节极限。算例分析和仿真验证表明:所提方法能够有效量化评估下垂控制的功率调节范围,为MTDC系统的安全稳定运行提供指导依据。
基金funded by SGCC Science and Technology Program under project Research on Electromagnetic Transient Simulation Technology for Large-scale MMC-HVDC Systems.
文摘Multi-terminal direct current(MTDC)grids provide the possibility of meshed interconnections between regional power systems and various renewable energy resources to boost supply reliability and economy.The modular multilevel converter(MMC)has become the basic building block for MTDC and DC grids due to its salient features,i.e.,modularity and scalability.Therefore,the MMC-based MTDC systems should be pervasively embedded into the present power system to improve system performance.However,several technical challenges hamper their practical applications and deployment,including modeling,control,and protection of the MMC-MTDC grids.This paper presents a comprehensive investigation and reference in modeling,control,and protection of the MMC-MTDC grids.A general overview of state-of-the-art modeling techniques of the MMC along with their performance in simulation analysis for MTDC applications is provided.A review of control strategies of the MMC-MTDC grids which provide AC system support is presented.State-of-the art protection techniques of the MMCMTDC systems are also investigated.Finally,the associated research challenges and trends are highlighted.
基金This work is supported by UK EPSRC and UK National Grid.
文摘This paper investigates a control and protection strategy for a four-terminal modular multilevel converter(MMC)based high-voltage direct current(HVDC)system under a converter-side AC fault.Based on the system operating condition,a control and protection strategy against the fault with normal blocking of the converter is proposed.In practical,applications encountering such a fault,the MMC at the fault side may experience different conditions of blocking failure.The blocking failures may occur on:①the whole converter;②one converter arm;③one sub-module(SM)/several SMs of one converter arm;④other conditions.The phenomenon of the multi-terminal HVDC(MTDC)system following the fault is analyzed under the first three conditions with real-time simulations using the real-time digital simulator(RTDS).Based on the impact of different conditions on the MTDC system,the necessity of utilizing special control and protection is discussed.A special control and protection strategy is proposed for emergency conditions,and its effectiveness is verified by real-time simulation results.
基金supported by the Key Science and Technology Projects of China Southern Power Grid Corporation(No.090000KK52180116)National Natural Science Foundation of China(No.51807135)。
文摘Featuring low communication requirements and high reliability,the voltage droop control method is widely adopted in the voltage source converter based multi-terminal direct current(VSC-MTDC)system for autonomous DC voltage regulation and power-sharing.However,the traditional voltage droop control method with fixed droop gain is criticized for over-limit DC voltage deviation in case of large power disturbances,which can threaten stable operation of the entire VSCMTDC system.To tackle this problem,this paper proposes an adaptive reference power based voltage droop control method,which changes the reference power to compensate the power deviation for droop-controlled voltage source converters(VSCs).Besides retaining the merits of the traditional voltage droop control method,both DC voltage deviation reduction and power distribution improvement can be achieved by utilizing local information and a specific control factor in the proposed method.Basic principles and key features of the proposed method are described.Detailed analyses on the effects of the control factor on DC voltage deviation and imbalanced power-sharing are discussed,and the selection principle of the control factor is proposed.Finally,the effectiveness of the proposed method is validated by the simulations on a five-terminal VSC based high-voltage direct current(VSC-HVDC)system.
基金supported in part by the National Natural Science Foundation of China (No.U2166202)S&T Program of Hebei (No.20312102D)。
文摘With the increasing use of renewable resources and electric vehicles(EVs), the variability and uncertainty in their nature put forward a high requirement for flexibility in AC distribution system incorporating voltage source converter(VSC) based multi-terminal direct current(MTDC) grids. In order to improve the capability of distribution systems to cope with uncertainty, the flexibility enhancement of AC-MTDC distribution systems considering aggregated EVs is studied. Firstly, the charging and discharging model of one EV is proposed considering the users' demand difference and traveling needs. Based on this, a vehicle-to-grid(V2G) control strategy for aggregated EVs to participate in the flexibility promotion of distribution systems is provided. After that, an optimal flexible dispatching method is proposed to improve the flexibility of power systems through cooperation of VSCs, controllable distributed generations(CDGs), aggregated EVs, and energy storage systems(ESSs). Finally, a case study of an AC-MTDC distribution system is carried out. Simulation results show that the proposed dispatching method is capable of effectively enhancing the system flexibility, reducing renewable power curtailment, decreasing load abandonment, and cutting down system cost.