This thesis addresses the issues existing in traditional laser tracking displacement measurement technology in the field of ultraprecision metrology by designing a differential signal processing circuit for high-preci...This thesis addresses the issues existing in traditional laser tracking displacement measurement technology in the field of ultraprecision metrology by designing a differential signal processing circuit for high-precision laser interferometric displacement measurement.A stable power supply module is designed to provide low-noise voltage to the entire circuit.An analog circuit system is constructed,including key circuits such as photoelectric sensors,I-V amplification,zero adjustment,fully differential amplification,and amplitude modulation filtering.To acquire and process signals,the PMAC Acc24E3 data acquisition card is selected,which realizes phase demodulation through reversible square wave counting,inverts displacement information,and a visual interface for the host computer is designed.Experimental verification shows that the designed system achieves micrometer-level measurement accuracy within a range of 0-10mm,with a maximum measurement error of less than 1.2μm,a maximum measurement speed of 6m/s,and a resolution better than 0.158μm.展开更多
Signals from infrared detector are very weak in SO2 concentration measuring system.In order to improve the sensitivity of detection,combining with filter correlation technology and infrared absorption principle,the we...Signals from infrared detector are very weak in SO2 concentration measuring system.In order to improve the sensitivity of detection,combining with filter correlation technology and infrared absorption principle,the weak signal processing circuit is designed according to correlation detection technology.Under laboratory conditions,system performance of SO2 concentration is tested,and the experimental data are analyzed and processed.Then relationship of SO2 concentration and the measuring voltage is provided to prove that the design improves measuring sensitivity of the system.展开更多
文摘This thesis addresses the issues existing in traditional laser tracking displacement measurement technology in the field of ultraprecision metrology by designing a differential signal processing circuit for high-precision laser interferometric displacement measurement.A stable power supply module is designed to provide low-noise voltage to the entire circuit.An analog circuit system is constructed,including key circuits such as photoelectric sensors,I-V amplification,zero adjustment,fully differential amplification,and amplitude modulation filtering.To acquire and process signals,the PMAC Acc24E3 data acquisition card is selected,which realizes phase demodulation through reversible square wave counting,inverts displacement information,and a visual interface for the host computer is designed.Experimental verification shows that the designed system achieves micrometer-level measurement accuracy within a range of 0-10mm,with a maximum measurement error of less than 1.2μm,a maximum measurement speed of 6m/s,and a resolution better than 0.158μm.
文摘Signals from infrared detector are very weak in SO2 concentration measuring system.In order to improve the sensitivity of detection,combining with filter correlation technology and infrared absorption principle,the weak signal processing circuit is designed according to correlation detection technology.Under laboratory conditions,system performance of SO2 concentration is tested,and the experimental data are analyzed and processed.Then relationship of SO2 concentration and the measuring voltage is provided to prove that the design improves measuring sensitivity of the system.