A new combined steel lead damper (NCSLD) was presented. Construction and working mechanism of NCSLD were introduced,pseudo-static tests of the small size dampers which would be used in the subsequent shaking table tes...A new combined steel lead damper (NCSLD) was presented. Construction and working mechanism of NCSLD were introduced,pseudo-static tests of the small size dampers which would be used in the subsequent shaking table tests were carried out for the study of mechanical properties of NCSLD using electro-hydraulic servo press-shear machine. Processing technology of the damper was improved. Shaking table tests under two-dimensional excitation on structural aseismic control of a one-story structure model were carried out using the small size NCSLD; parameters of the structure and shaking table were also introduced. Results indicate that process improvement is beneficial to the implementation of working mechanism of the damper,NCSLD has full hysteresis loop which takes on bilinearity,NCSLD has obvious energy dissipation effect and it can control structural seismic response effectively.展开更多
This paper presents exact analytical solutions for a novel damped outrigger system, in which viscous dampers are vertically installed between perimeter columns and the core of a high-rise building. An improved analyti...This paper presents exact analytical solutions for a novel damped outrigger system, in which viscous dampers are vertically installed between perimeter columns and the core of a high-rise building. An improved analytical model is developed by modeling the effect of the damped outrigger as a general rotational spring acting on a Bernoulli-Euler beam. The equivalent rotational spring stiffness incorporating the combined effects of dampers and axial stiffness of perimeter columns is derived. The dynamic stiffness method(DSM) is applied to formulate the governing equation of the damped outrigger system. The accuracy and effi ciency are verifi ed in comparison with those obtained from compatibility equations and boundary equations. Parametric analysis of three non-dimensional factors is conducted to evaluate the infl uences of various factors, such as the stiffness ratio of the core to the beam, position of the damped outrigger, and the installed damping coeffi cient. Results show that the modal damping ratio is signifi cantly infl uenced by the stiffness ratio of the core to the column, and is more sensitive to damping than the position of the damped outrigger. The proposed analytical model in combination with DSM can be extended to the study of structures with more outriggers.展开更多
基金Sponsored by the National Natural Science Foundation of China (Grant No. 50508012)Science &Technology Plan Project of Guangdong Province(Grant No. 20055190030)+1 种基金Key Basic Research Project of Science and Technology Ministry (Grant No. 2004CCA03300)Science &Technology Project of Guangzhou Education Bureau(Grant No.08C05)
文摘A new combined steel lead damper (NCSLD) was presented. Construction and working mechanism of NCSLD were introduced,pseudo-static tests of the small size dampers which would be used in the subsequent shaking table tests were carried out for the study of mechanical properties of NCSLD using electro-hydraulic servo press-shear machine. Processing technology of the damper was improved. Shaking table tests under two-dimensional excitation on structural aseismic control of a one-story structure model were carried out using the small size NCSLD; parameters of the structure and shaking table were also introduced. Results indicate that process improvement is beneficial to the implementation of working mechanism of the damper,NCSLD has full hysteresis loop which takes on bilinearity,NCSLD has obvious energy dissipation effect and it can control structural seismic response effectively.
基金973 Program under Grant under Grant No.2012CB723304It was partially supported by the Major Research Plan of the National Natural Science Foundation of China under Grant No.91315301-07+2 种基金in part by Program for Changjiang Scholars and Innovative Research Team in University under Grant No.IRT13057the Ministry of Education Program for New Century Excellent Talents in University under Grant No.NCET-11-0914the Guangzhou Ram Scholar Program Grant No.10A032D
文摘This paper presents exact analytical solutions for a novel damped outrigger system, in which viscous dampers are vertically installed between perimeter columns and the core of a high-rise building. An improved analytical model is developed by modeling the effect of the damped outrigger as a general rotational spring acting on a Bernoulli-Euler beam. The equivalent rotational spring stiffness incorporating the combined effects of dampers and axial stiffness of perimeter columns is derived. The dynamic stiffness method(DSM) is applied to formulate the governing equation of the damped outrigger system. The accuracy and effi ciency are verifi ed in comparison with those obtained from compatibility equations and boundary equations. Parametric analysis of three non-dimensional factors is conducted to evaluate the infl uences of various factors, such as the stiffness ratio of the core to the beam, position of the damped outrigger, and the installed damping coeffi cient. Results show that the modal damping ratio is signifi cantly infl uenced by the stiffness ratio of the core to the column, and is more sensitive to damping than the position of the damped outrigger. The proposed analytical model in combination with DSM can be extended to the study of structures with more outriggers.