A circuit model of the Amperometric immunosensor for use in the biosensor system-on-chip simulation is proposed in this paper.The model parameters are extracted with several methods and verified by MATLAB and SPICE si...A circuit model of the Amperometric immunosensor for use in the biosensor system-on-chip simulation is proposed in this paper.The model parameters are extracted with several methods and verified by MATLAB and SPICE simulation.A CMOS potentiostat circuit required for conditioning the Amperometric immunosensor is also included in the circuit model.The mean square error norm of the simulated curve against the measured one is 8.65×10^(-17) The whole circuit has been fabricated in a 0.35μm CMOS process.展开更多
One of today's challenges is the integration of ISFETs in chemical and biochemical Microsystems.This article presents a full integration of ISFET chip containing the ISFET/REFET(reference FET) pair,ISFET/REFET amp...One of today's challenges is the integration of ISFETs in chemical and biochemical Microsystems.This article presents a full integration of ISFET chip containing the ISFET/REFET(reference FET) pair,ISFET/REFET amplifiers,bias current generator,as well as a reference electrode structure,all integrated on the same chip based on CMOS technology.The sensor chip was fabricated in a standard 0.35μm CMOS process(Chartered Semiconductor,Singapore).The extra post processing steps have been developed and added for depositing membranes.Finally,the pH response of the integrated sensor was measured with the interface circuit.展开更多
基金supported by National Natural Science Foundation of China,No.90307014
文摘A circuit model of the Amperometric immunosensor for use in the biosensor system-on-chip simulation is proposed in this paper.The model parameters are extracted with several methods and verified by MATLAB and SPICE simulation.A CMOS potentiostat circuit required for conditioning the Amperometric immunosensor is also included in the circuit model.The mean square error norm of the simulated curve against the measured one is 8.65×10^(-17) The whole circuit has been fabricated in a 0.35μm CMOS process.
基金supported by National Natural Science Foundation of China(No.90307014)
文摘One of today's challenges is the integration of ISFETs in chemical and biochemical Microsystems.This article presents a full integration of ISFET chip containing the ISFET/REFET(reference FET) pair,ISFET/REFET amplifiers,bias current generator,as well as a reference electrode structure,all integrated on the same chip based on CMOS technology.The sensor chip was fabricated in a standard 0.35μm CMOS process(Chartered Semiconductor,Singapore).The extra post processing steps have been developed and added for depositing membranes.Finally,the pH response of the integrated sensor was measured with the interface circuit.